 - Designed specifically for the cleanup of sample extracts for organochlorine pesticides analysis.
- Excellent alternative to Florisil products, especially for the removal of nonvolatile matrix components that contaminate GC inlets and columns.
- Proprietary treatment renders the carbon consistent and clean, ensuring the same selectivity tube to tube, and lot to lot with no interfering background.
- Uses the same hardware, solvents, and solvent volumes as traditional Florisil cleanup, so switching is simple.
View Product Information |
 - Improved recovery of sulfonylurea herbicides, phenols, carbamates, and triazine herbicides, compared to C18 and C8 cartridges.
- Wide range of selectivity for both analytes and their metabolites or degradation products.
- Rapid sampling flow rates; uncompromised recoveries.
- Maximum capacity for contaminant cleanup.
- Controlled manufacturing improves cleanliness and ensures reproducible performance.
- Excellent performance removing pigments from samples.
View Product Information |
 - Convenient, multiple adsorbent beds in a single cartridge.
- For use in multiresidue pesticide analysis to remove matrix interferences.
- Excellent for cleanup of dietary supplement extracts.
View Product Information |
 These cartridges have been specifically designed to provide consistent and reproducible results for the method or application stated. View Product Information |
 Hydrophilic (polar) adsorbents used to extract hydrophilic analytes from nonpolar matrices, such as organic solvents (e.g., polar contaminants from sample extracts).
Meets requirements of EPA Methods 515.2 and 553. View Product Information |
 - Method-specific performance for extractable petroleum hydrocarbon (EPH) analysis of soil and water samples.
- Complete separation of aliphatic and aromatic compounds into distinct fractions.
- Guaranteed background level under the strict reporting limits of MA and NJ EPH methods.
- Superior lot-to-lot reproducibility and storage stability ensured by rigorous QC testing and moisture-resistant packaging.
- Choose 5 g cartridges for higher loading capacity; use 2 g cartridges for automated systems, time-saving, and solvent reduction.
View Product Information |

- Faster and easier than SPE and liquid-liquid extraction: just load, wait 5 minutes, then elute.
- Effective removal of proteins, phospholipids, and salts.
- Quick concentration step increases sensitivity.
- Easy to automate for high-throughput laboratories.
- Suitable for a wide range of sample matrices and analyte pKa values.
Volume guidelines: Selecting an SLE format with sufficient loading capacity (1 mg sorbent to 1µL diluted sample) is very important because the entire sample volume (including 1:1 dilution in buffer) is absorbed into the diatomaceous earth sorbent. For example, a 100 µL sample should be diluted 1:1 with buffer for a total volume of 200 µL, which requires use of a 200 mg SLE product. View Product Information |

- High-purity material with highest reproducibility and lowest blank values due to an optimized manufacturing process.
- Excellent recovery rates, especially for the enrichment of pharmaceuticals and active ingredients, due to the spherical particle shape, homogeneous surface, and optimized pore structure.
- Hydrophobic styrene-divinylbenzene (SDVB) copolymer, pH stability 1–14.
- Recommended analytes: pharmaceuticals/active ingredients from tablets, creams and water/wastewater; drugs from blood, plasma, serum, and urine; trace analysis of herbicides, pesticides, PAHs, PCBs, and phenols from water.
View Product Information |

- Remove both proteins and phospholipids from biological samples in one easy, high-efficiency procedure.
- Avoid signal suppression by removing interfering phospholipids from the sample matrix.
- No method development—straightforward and effective sample preparation for acids, bases, and neutral compounds.
- Offered in 96-well plate format for high-throughput or automated workflows and in cartridge format for lower throughput applications.
- 3-way versatility for filtration—compatible with all common devices:
- Vacuum manifolds
- Positive pressure manifolds
- Centrifugation
View Product Information |

- Silica-free, bonded polymeric material—no unwanted secondary silica interactions, even with basic compounds.
- High surface area—higher loading capacity compared to silica-based sorbents.
- Stable over a wide pH range (0–14)—won’t hydrolyze under extreme conditions.
- Water-wettable—streamlined conditioning and equilibration steps drastically reduce solvent usage and sample prep time.
- No flow-rate dependence—maintains retention and capacity after conditioning, even if dried out from vacuum or positive pressure flows.
- Choose cartridges for high loading capacity; 96-well plates for high throughput and automation.
View Product Information |
 - High quality anhydrous sodium sulfate.
- Approximately 2 grams prepackaged in a convenient capped cartridge with both male and female luer ends for easy connection to a variety of devices or equipment.
- The adsorbent is fully activated and ready to use for removal of excess water from organic solvent solutions, prior to many types of analysis.
- Capped cartridges will remain active for long periods of storage in the lab.
View Product Information |
 - High adsorbent capacity (surface area ~200 m2/g) for large volume sampling.
- Chromatographic grade graphitized carbon provides consistent and quantitative recoveries of a wide variety of semivolatiles, pesticides, and herbicides.
- 500 mg bed weight.
View Product Information |
 |
 Hydrophobic (nonpolar) silica-based adsorbents; used to extract hydrophobic analytes from polar matrices, such as water (e.g., pesticides from water).
C18 (high load, end-capped) View Product Information |