Detector Supplies
Products |
---|
![]() ETP Electron Multipliers for Mass Spectrometry
View Product Information |
![]() MSD Source Nutfor Agilent GCs with 5971/5972, 5973, 5975, or 5977 GC-MS
View Product Information |
![]() EZ No-Vent GC Column-Mass Spectrometer Connectorfor Agilent GCs with 5971/5972, 5973, 5975, or 5977 GC-MS
View Product Information |
![]() Inland 45 Pump OilRecommended for most mass spectrometers.
View Product Information |
![]() MSD Conversion Fittingfor Agilent GCs with 5971/5972, 5973, 5975, or 5977 GC-MS
View Product Information |
![]() FID Jetsfor Shimadzu 2010 GCs |
![]() High-Temperature EI Filamentfor Agilent 5972, 5973, 5975, or 5977 GC-MS
View Product Information |
![]() Methanizer (CH4izer)
View Product Information |
![]() ECD Make-Up Gas Kitsfor Agilent 6890/7890 GCs |
![]() EZ No-Vent GC Column-Mass Spectrometer Connectorfor Shimadzu QP 2010 & QP 2010 Plus
View Product Information |
![]() GC-MS Cleaning KitPoor sensitivity, loss of sensitivity at high masses, or high multiplier gain during an auto-tune are all indicators that your mass spectrometer source may need to be cleaned. Restek has assembled all of the necessary components for cleaning and polishing your ion source. View Product Information |
![]() Gold Tip Transfer Line
View Product Information |
![]() EZ No-Vent GC Column-Mass Spectrometer Connectorfor Thermo Scientific Focus DSQ GC Mass Spectrometers
View Product Information |
![]() EZ No-Vent GC Column-Mass Spectrometer Connectorfor Bruker/Varian Saturn 2000 Series Mass Spectrometers
View Product Information |
![]() MS Nutfor Shimadzu 2030 GC-MS instruments with QP2020 NX or QP2010 SE mass spectrometers
View Product Information |
![]() Heater/Sensor Assemblyfor Agilent 6850/6890/7890/8890 GCs
View Product Information |
![]() FID Maintenance Kitsfor Agilent GCs
View Product Information |
![]() FID Jetfor Thermo Scientific TRACE & Focus GCs |
![]() Transfer Line Reducing Kitfor Thermo Scientific TRACE & Focus DSQ Mass Spectrometers |
![]() FID Collector Housing Kitsfor Agilent GCs
View Product Information |
![]() FID Jet Removal Toolfor Agilent 5890/6850/6890/7890 FIDs
View Product Information |
![]() Spanner Wrenchfor Agilent 5890/6850/6890/7890 FID Collector Assemblies
View Product Information |
![]() FID Capillary Column Adaptorsfor PerkinElmer Auto SYS XL
View Product Information |
![]() FID Replacement Partsfor PerkinElmer Auto SYS XL and Clarus 500
View Product Information |
![]() FID Base Weldmentfor Agilent GCs
View Product Information |
![]() FID Collector Mountfor Agilent GCs
View Product Information |
![]() Ion Source Cleaning PowderUse this aluminum oxide powder to clean surfaces that contact the sample or ion beam when you encounter poor sensitivity and inadequate abundances at high masses. View Product Information |
![]() Rough Pump Oil #19 for MSD Pumps, Oil Vacuum Pump
View Product Information |
![]() Heater Cartridge & Platinum Resistance Thermometer (PRT) Sensorfor Agilent 5890 GCs
View Product Information |
![]() Capillary Installation Gaugefor Agilent 5973/5975/5977 MS
View Product Information |
![]() FID Collector Assembly Kitfor Agilent 6850/6890/7890 GCs
View Product Information |
![]() Photoionization (PID) LampsModel 108-10.0/10.6 offers both 10.0 and 10.6 eV potential, has a 0.781" base diameter, and is used in SRI, Tracor, OI, and Baseline instruments. Model 103 has a 1.375" base and is used in HNU detectors. Model 108-BTEX lamp’s higher output makes it ideal for detection of BTEX compounds. View Product Information |
![]() FID Gauge Packfor Agilent 5890 GCs
View Product Information |
![]() FID/Injector Cleaning KitUse Restek’s Cleaning Kit with ANY injection port! The FID/injector cleaning kit includes:
View Product Information |
![]() ECD/FID Dual-Purpose Make-Up Gas Kitfor Agilent 5890 GCsKit includes: replacement fitting, 1/4" nut, Vespel/graphite ferrule, 1/16" nut, 0.4 mm ID graphite ferrule, Siltek-treated guide. View Product Information |
![]() Packed Column FID Replacement Jetsfor Agilent 5890/6850/6890 GCs
View Product Information |
![]() Capillary Dedicated FID Replacement Jetfor Agilent 5890/6850/6890/7890 GCsAvailable in standard, high-temperature, or Siltek-treated, high-performance versions. View Product Information |
![]() Capillary Adaptable FID Replacement Jetfor Agilent 5890/6850/6890 GCsAvailable in standard or Siltek-treated, high-performance versions. Engineered with a fluted tip to guide the capillary column into the jet. View Product Information |
![]() FID/NPD Capillary Adaptor Fittingfor Agilent 5890/6850/6890 GCs
View Product Information |
![]() FID/NPD Adaptor Fitting
View Product Information |
![]() Injector/Detector Plug Nutsfor Agilent, PerkinElmer 590/690, and Thermo 1300/1310 GCs
View Product Information |
![]() FID Flow Measuring Adaptorfor Agilent GCs
View Product Information |
![]() FID Collector Assembly Kitfor Agilent 5890 GCs
View Product Information |
![]() Stainless Steel Jet Reamers / Ferrule RemoversA great tool for cleaning detector jets or removing stuck ferrules from other small orifices. Serrated design is optimal for removing silica deposits and other contaminants. View Product Information |
![]() |
![]() |
![]() |
![]() Replacement Ring Seal for MSD Conversion Fittingfor Agilent GCs with 5971/5972, 5973, 5975, or 5977 GC-MS |
![]() Replacement Parts for FID Collector Housing Kitsfor Agilent GCs |
![]() Replacement Parts for FID Collector Assembly Kitfor Agilent GCs |
![]() |
![]() |