 - Proton exchange membrane (PEM) cell eliminates the need for liquid electrolytes.
- Maintenance-free palladium purifier removes oxygen to <0.01 ppm and moisture to <1.0 ppm.
- Produces continuous supply of 99.99999+% pure hydrogen gas.
- Does not require downstream gas filters.
- Maximum outlet pressures of 100 or 175 psig (690 or 1,200 kPa).
- Automatic safety feature shuts the generator down if a hydrogen leak is detected.
- Compact unit, requires only one square foot of bench space.
- Warranty: one year from date of purchase on system and three years from date of purchase on cell life.
View Product Information |

- Turn compressed air into ultra-pure nitrogen (up to 99.5%).
- Flows from 1 to 44 L/min.
- Models N2-04, N2-14, N2-22, and N2-35 require no electricity.
- Safe, reliable, low maintenance.
- Maintenance kits include replacement filters.
- 12-month warranty from date of purchase.
View Product Information |
 - Proton exchange membrane (PEM) cell eliminates the need for liquid electrolytes.
- Reliably generate 99.9995% pure hydrogen—for better chromatography.
- Eliminates high-pressure cylinders—greater convenience and improved lab safety.
- Compact unit, requiring only one square foot of bench space.
- Quick and easy to service and maintain; unique display lighting changes color for easy status checks and water level indication.
- Comes with a set of universal power adapters for U.S., European, and Asian plug types.
- Automatic safety feature shuts the generator down if a hydrogen leak is detected.
- Warranty: one year from date of purchase on system and two years from date of purchase on cell life.
View Product Information |
 - Single unit produces UHP zero air from house compressed air and 99.9995% pure hydrogen from deionized water.
- Ideal for supplying up to 5-6 FIDs.
- Eliminates inconvenient and dangerous gas cylinders.
- Silent operation, minimal operator attention required.
- 12-month warranty from date of purchase.
View Product Information |
 - Produces ultra-pure nitrogen (up to 99.9999%).
- Requires only a compressed air source and 110 volt AC power.
- Typical applications include GC carrier gas, make-up gas, and low-flow sample concentrators.
- Maintenance kits include replacement filters.
- 12-month warranty from date of purchase.
View Product Information |
 - Turn in-house compressed air into ultra-pure air (<0.1 ppm total hydrocarbons).
- Remove hydrocarbons to less than 0.1 ppm by catalytic oxidation.
- Operate at 40–125 psi (276–862 kPa).
- Typical payback is less than one year, based on cylinder costs.
- Install easily and take up little bench space.*
- Maintenance kits include a one-year supply of prefilters and final filter.
View Product Information |
 - Economical means of providing deionized water to hydrogen generators, or for other uses.
- Quick and easy installation; minimal maintenance.
- Removes organics, phosphates, chlorine, and essentially all ionizable constituents from your water supply.
- Easy-fill dispensing gun.
- Visual indication for cartridge changes.
- 12-month warranty from date of purchase.
View Product Information |
 |
 |
 |
 |
 |
 |
 |