- High-purity output ensures 99.9999% pure gas (at max. flow of 2 L/min).
- Designed for easy, hassle-free cartridge changes.
- Glass inside to prevent diffusion; polycarbonate housing outside for safety.
- The indicator code is shown on every trap so there is no confusion determining when a trap needs to be replaced.
View Product Information |
 - Removes up to 135 ml of oxygen or 2 g of water.
- Long life—typically purifies more than 480 cu ft of inert gas.
- Reduces oxygen to 15 ppb.
- Maximum operating pressure: 250 psi (1,724 kPa).
- Flow: 3 L/min @ 32 psi (221 kPa).
View Product Information |
 - Packed with an extremely high surface area, baked coconut shell–based activated carbon.
- Purged with ultra-high-purity helium; ready to use with any carrier gas including hydrogen.
- Reduces organics to 0.1 ppm (assuming 100 ppm input).
- Maximum operating pressure: 250 psi (1,724 kPa).
View Product Information |

- Reduces water to less than 10 ppb. Indicator changes from yellowish green to blue at 5% relative humidity (suitable for general use).
- Pre-purged for fast stabilization.
- Reduces noise from high-sensitivity detectors.
- Heavy-walled glass body prevents oxygen and water infusion.
- 10 μm frit prevents microparticulate damage to needle valves and flow controllers.
- Maximum operating pressure: 100 psi (689 kPa).
View Product Information |

- Removes oxygen to low ppb levels from He, Ar, N2, or methane.
- Indicator changes from green to gray when adsorption capacity is depleted.
- Can be used with nonoxidizing gases such as He, Ar, N2, H2, or CH4.
- Heavy-walled inner glass tube is protected by a sealed outer plastic tube to prevent oxygen and water infusion.
- Prepurged for fast stabilization.
- 100 psi (689 kPa) maximum operating pressure.
- Reduces oxygen to 100 ppb.
- 10 µm frits at inlet and outlet.
- Optimal flow rate: < 150 mL/min.
View Product Information |
 |
 - High-purity output ensures 99.9999% pure gas.
- Click-On fittings for easy, leak-tight cartridge changes; brass or stainless steel, 1/4" or 1/8".
- Triple gas trap is ideal for purifying carrier gas—it contains oxygen, moisture, and hydrocarbon scrubbers in one cartridge.
- Fuel gas trap is ideal for purifying flame ionization detector (FID) fuel gases, removing both moisture and hydrocarbons.
- Helium-specific triple gas trap is ideal for GC-MS—it contains oxygen, moisture, and hydrocarbon scrubbers in one cartridge.
View Product Information |
 - Largest-capacity traps available—run longer without replacing.
- Maximum operating pressure of 11 bar (160 psig).
- High-purity output ensures 99.9999% pure gas (maximum flow of 8 L/min).
- Triple gas trap is ideal for purifying carrier gas.
- Helium-specific triple gas trap is made for GC-MS—ready to use within 15 minutes of installation.
- Hydrocarbon trap removes hydrocarbon contamination from carrier gas to help eliminate ghost peaks.
Note: Replacement filter only—fittings sold separately. View Product Information |
 - Largest-capacity traps available—run longer without replacing.
- "Quick connect" fittings with spring-loaded check valves allow filter replacement in seconds without tools or contamination.
- Maximum operating pressure of 11 bar (160 psig).
- High-purity output ensures 99.9999% pure gas (maximum flow of 8 L/min).
- Triple gas trap is ideal for purifying carrier gas.
- Helium-specific triple gas trap is made for GC-MS—ready to use within 15 minutes of installation.
- Hydrocarbon trap removes hydrocarbon contamination from carrier gas to help eliminate ghost peaks.
View Product Information |
 Restek Super Clean ultra-high capacity oxygen filter cartridges feature easy-to-read indicators.
The indicator code is shown on every trap so there is no confusion determining when a trap needs to be replaced. View Product Information |
 Restek Super Clean ultra-high capacity moisture filter cartridges feature easy-to-read indicators.
The indicator code is shown on every trap so there is no confusion determining when a trap needs to be replaced. View Product Information |
 |
 - Removes trace impurities from carrier gas.
- Reduces organics to 0.1 ppm (assuming 100 ppm input).
- 60 µm frit prevents gas contamination by purifier particles.
- Good for purge-and-trap systems.
- Refillable and rechargeable.
- Maximum operating pressure: 125 psig (862 kPa).
- Maximum flow: 5 L/min.
View Product Information |
 - Purged with ultra-high-purity helium; ready to use with any carrier gas including hydrogen.
- Reduces water to less than 15 ppb.
- Maximum operating pressure: 250 psi (1,724 kPa).
- Maximum flow: 1.25 L/min.
View Product Information |
 - Removes moisture, hydrocarbons, and oxygen from carrier gas, extending column lifetime.
- Produces high-purity carrier gas for most applications.
- Includes one each: moisture, hydrocarbon, and indicating oxygen trap.
- Replacing traps is safe and easy.
- Maximum flow: 150 cc/min for optimal performance.
View Product Information |

- Removes carbon dioxide from inert gases He, Ar, N2, H2, and clean dry air (CDA) to low ppb levels.
- Functions by consuming carbon dioxide in a reaction with highly dispersed NaOH on a silicate support (reaction produces water that remains adsorbed in the purifier).
- In highly critical applications, consider using an additional moisture trap after the CO2 trap as a safety measure.
View Product Information |

- Removes moisture and hydrocarbons (C5 and heavier) from dry air or inert gases.
- Indicator signals breakthrough by changing from yellowish green to blue at low relative humidity to warn of leaks in the gas stream.
- The inner glass tube contains activated carbon, moisture indicator, and molecular sieve.
- 10 μm frits at both ends of the filter.
- Heavy-walled inner glass tube is protected by a sealed outer plastic tube to further protect against leaks.
View Product Information |

- Removes multiple impurities such as O2, H2O, CO2, CO, halogenated compounds, siloxanes, hydrocarbons (heavier than butane), sulfur-containing molecules, and ammonia from inert gases (He, Ar, N2, and H2).
- Can be used with other filters to provide endpoint detection.
- Contains highly sensitive visual indicators for oxygen and water contamination. The oxygen indicator signals breakthrough when the adsorbent changes from green to grey, and the moisture indicator signals breakthrough by changing from blue to brown.
- Heavy-walled inner glass tube is protected by a sealed outer plastic tube to further protect against leaks.
View Product Information |
 - Audiovisual warning system ensures maintenance is done on time.
- Progressively displays gas filter status, preventing unplanned downtime for maintenance.
- Can be custom configured to your replacement/maintenance schedule.
View Product Information |
 Protect your instrument and improve data quality with this powerful pair from Restek. Checking for leaks and verifying flows before you start running help you avoid costly problems later. View Product Information |
 |
 |
 |
 Flowmeters that can measure flammable gases are becoming mandatory due to the increased use of hydrogen in chromatography. With its Ex rating, the Restek ProFLOW 6000 meter is designed specifically with explosive and flammable gases in mind.
The Restek ProFLOW 6000 is the only flowmeter you need for any type of chromatography gas measurement because of its wide range of capabilities. The ProFLOW 6000 is an electronic meter capable of measuring volumetric flow for most gases. Real-time measurements can be made for various types of flow paths, including continually changing gas types. This portable unit is designed for easy handheld use, and the stand adds benchtop convenience. View Product Information |
 New and improved! Prevent small leaks from causing big problems with a Restek leak detector.
- Detects a broad range of gases and indicates leak severity with both an LED display and audible tone.
- No more waiting for a full charge—can be operated during charging or used up to 12 hours between charges.
- Charging kit includes both universal AC power adaptor and USB charging cable so you can charge anywhere, anytime.
- Pinpoint very small gas leaks quickly and accurately before they cause damage and downtime.
- Compact, handheld unit is easy to operate and convenient to use anywhere you need to check for leaks.
View Product Information |
 |
 |
 Click-On connectors allow you to change traps quickly, without introducing oxygen into your system. View Product Information |
 |
 |
 A Super Clean quick-change cartridge system efficiently removes hydrocarbons from nitrogen! - Designed for easy, hassle-free cartridge changes.
- Up to 20 L of hydrocarbon-free nitrogen per minute.
- Filters connected in parallel to handle high flows for LC-MS.
View Product Information |
 - Use an in-line pressure gauge to indicate when a thermal gas purifier getter tube should be replaced.
- Includes 1/8" tee and 0–100 psi (0-689k Pa) gauge.
View Product Information |
 - End fittings available in brass or stainless steel.
- Baseplates fit all stand-alone Super Clean gas filters offered.
View Product Information |
 - Removes hydrocarbons and other contaminants.
- Reduces organics to 0.1 ppm (assuming 100 ppm input).
- Each individually activated to ensure maximum efficiency.
- Fits in GC oven for easy thermal recharging.
- Maximum operating pressure: 60 psi (414 kPa).
View Product Information |
 - Reduces the release of hazardous materials from the ECD vent into the lab.
- Includes connecting lines and mounting kit.
View Product Information |

- Replace separate traps for removing impurities (e.g., moisture and hydrocarbons) with one multiple-bed purifier that is designed specifically for purifying helium, hydrogen, nitrogen, or air.
- Reduce gas impurities from ppm to low ppb levels.
- Decrease baseline noise and increase GC-MS sensitivity.
- Pre-purged with the specified gas to shorten downtime.
View Product Information |
 - Reduces the release of hazardous materials from the capillary split vent into the lab.
- Includes connecting lines and mounting kit.
View Product Information |
 - Traps water vapor; increases column and oxygen trap lifetime.
- Reduces baseline noise from sensitive detectors such as ECDs and mass spectrometers.
- Activated and ready to use.
- Reduces water to less than 1 ppm.
- Maximum flow: 1 L/min.
View Product Information |
 For current leak detector model only (cat.# 28500); not compatible with legacy model (cat.# 22655). View Product Information |
 |
 |
 |
 |
 |
 |
 |

- High-purity output ensures 99.9999% pure gas (at max. flow of 2 L/min).
- Designed for easy, hassle-free cartridge changes.
- Glass inside to prevent diffusion; polycarbonate housing outside for safety.
- The indicator code is shown on every trap so there is no confusion determining when a trap needs to be replaced.
View Product Information |
 Optional soft-sided storage case is ideal for storing your leak detector or flowmeter in smaller spaces, such as your toolbox.
Compatible with both current (cat.# 28500) and legacy (cat.# 22655) leak detector models. View Product Information |
 Parker’s (A-Lok) fittings are ideal for installing new equipment, modifying existing instrumentation, or replacing worn connections. Fittings are available in brass and stainless steel. Siltek/Sulfinert treated or Silcosteel-CR treated fittings are also available. If there is a particular Parker fitting that you are looking for and it is not listed here, please contact us to inquire about availability. View Product Information |
 Baseplates can be mounted by using screws and the mounting holes on the baseplate, or by using this optional wall mounting bracket. View Product Information |
 |
 |
 For legacy leak detector model only (cat.# 22655); not compatible with current model (cat.# 28500). View Product Information |