Other Inlet Supplies

Products

Flip Seal Dual Vespel Ring Inlet Seals

Restek Innovation! Patented.

Reversible Flip Seal Inlet SealSame Cost, Extended Lifetime
  • Reversible, two-sided design allows significantly more analyses than other seals, at the same pricesimply use, flip, then use again!
  • Vespel ring embedded in top and bottom surface eliminates need for a washer.
  • Highly inert gold seals reduce breakdown and adsorption of active compounds, maximizing component transfer to GC column.
  • Very little torque required to make sealreduces operator variability.

    Note: The Flip Seal inlet seal requires a special reducing nut adaptor fitting, which is included in the kit.

View Product Information

Dual Vespel Ring Inlet Seals

Washerless, Leak-Tight Seals for Agilent GCs

  • Does not require a separate washer.
  • Requires less torque to seal.
  • Does not require retightening of reducing nut after several oven cycles.
  • Extends column lifetime by preventing oxygen from reaching the column.
  • Same price as the regular inlet seals with washers.
  • Gold plating provides enhanced inertness versus stainless steel.

View Product Information

Inlet Maintenance Kit

for Agilent GCs

  • Includes the most common consumable GC supplies and tools.
  • All parts meet or exceed performance of instrument manufacturer’s parts.
  • Parts list makes reordering easy.

View Product Information

Capillary Column Nuts

for Agilent, PerkinElmer 590/690, and Thermo 1300/1310 GCs

Available in brass or stainless steel.

View Product Information

Finger-Tight Capillary Column Nuts

for Agilent, PerkinElmer 590/690, and Thermo 1300/1310 GCs

  • Allow wrench-free column installations.
  • Available for standard (1/16") and compact (Agilent-style) ferrules.
  • Made from high-quality stainless steel.

View Product Information

Finger-Tight Capillary Column Nuts

  • Rapidly tighten without wrenches; avoid stripped threads.
  • Either version can be used with 0.25, 0.32, or 0.53 mm ID columns.

View Product Information

Inlet Wrench

for Agilent 5890/6850/6890 GCs

  • Use to remove the septum nut and weldments during GC maintenance.
  • Use the smaller end to remove the septum nut.
  • Use the larger end to tighten the split/splitless weldment nut.
  • High-quality stainless steel construction.
  • Meets original equipment performance.

View Product Information

Septum Nuts

for use with Agilent 5890/6850/6890/7890 Split/Splitless Injectors

  • Needle guide allows easy penetration and prevents septum coring.
  • Manual injection septum nut allows use of 26-gauge needles for on-column injections.
  • Made of high-quality stainless steel.

View Product Information

Septum Nut Removal Tool

for Agilent 5890/6850/6890/7890 GCs

  • Easily remove the septum nut without touching the heated nutno more burned fingers!
  • Unique, ergonomic handleeasy to grip.
  • Nut remains in tool for quick reattachment.

View Product Information

1/16-Inch Capillary Inlet Adaptor Fitting Kit

Split/Splitless Fitting for Capillary Columns

  • 1/16-inch split/splitless fitting that accepts standard capillary ferrules.
  • Easier to install capillary columns because the nut protrudes farther from the insulated injection port chamber.
  • Same column insertion depth as the original manufacturer's equipment.
  • Kit includes adaptor fitting, capillary nut, gold plated 0.8 mm ID Dual Vespel Ring Inlet Seal, and one 0.4 mm ID ferrule.

View Product Information

Extended Capillary Column Nuts

for Agilent 5890/6850/6890/7890 GCs

  • Visible below inlet insulating cup for easy, breakage-free column installation without removing cup.
  • Finger-tight design to allow wrench-free use.
  • Available for standard (1/16") and compact (Agilent-style) ferrules.
  • Made from high-quality stainless steel.
  • Meets or exceeds original manufacturer's performance.

View Product Information

Viton O-Rings

for Shimadzu 17A, 2010, 2014, and 2030 GCs

Dual Vespel Ring Cross-Disk Inlet Seals

for Agilent GCs

  • Ideal for high-flow split applications >500 mL/min.
  • Washerless, leak-tight seals.

View Product Information

Fixing Nut for Capillary Column

for Split/Splitless Injector on Thermo Scientific TRACE, 8000, 8000 TOP & Focus SSL

Made of high-quality stainless steel.

View Product Information

Silver Seals

for Thermo Scientific TRACE, 8000, 8000 TOP & Focus SSL

Injector Adaptors

for PerkinElmer CAP Injector

  • Made of high-quality stainless steel.
  • Meet or exceed original manufacturer's performance.
  • Siltek-treated version available for increased inertness.

View Product Information

Restek Enhanced Capillary Nut

for Shimadzu 17A, 2010, 2014, and 2030 GCs

  • Restek’s design eliminates the slot, increasing lifetime and durability.
  • Meets or exceeds original manufacturer's performance.

View Product Information

Viton O-Rings

for PerkinElmer PSS Injector

Fits 4 mm OD liners.

View Product Information

Silicone O-Rings

for PerkinElmer Auto SYS XL or Clarus 580/680 GCs with CAP Injector

Fits 6.2 mm OD liners.

View Product Information

Capillary Nut

for Shimadzu 17A, 2010, 2014, and 2030 GCs

Meets original manufacturer's performance.

View Product Information

Liner Seals

for Bruker/Varian 1078/1079 GCs

Inlet Liner Seals

for Bruker/Varian 1177 Injectors

Meets or exceeds original manufacturer’s performance.

View Product Information

Graphite Sealing Ring

for Thermo Scientific TRACE, 8000, 8000 TOP & Focus SSL instruments; fits 8 mm OD liners

Siltek Treated Inlet Support Springs

for Bruker/Varian 1075/1077 Split Injectors

Siltek treated to eliminate sample adsorption.

View Product Information

Capillary Nuts

for Bruker/Varian GCs

Choose brass or stainless steel construction.

View Product Information

Replacement Inlet Seals

for PerkinElmer Clarus 590/690 GCs

  • Gold plating provides inertness similar to fused silica.
  • All seals include washers.

View Product Information

MS Interface Nut

for Thermo Scientific ISQ

1/16" x 1.2 mm hole (extended). Made of high-quality, nickel-plated brass.

View Product Information

Oven Shrouds

for Agilent 6890/7890 GCs

  • Includes heating coil and oven temperature sensor.
  • Available in 120 V and 220 V units.

View Product Information

Dual Vespel Ring Inlet Seals

Washerless, Leak-Tight Seals for Thermo TRACE 1300/1310 GCs and PerkinElmer Clarus 590/690 GCs

  • Does not require a separate washer.
  • Requires less torque to seal.
  • Does not require retightening of reducing nut after several oven cycles.
  • Extends column lifetime by preventing oxygen from reaching the column.
  • Same price as the regular inlet seals with washers.
  • Gold plating provides enhanced inertness versus stainless steel.

View Product Information

Viton O-Rings

For Agilent, PerkinElmer 590/690, Thermo 1300/1310, and Varian 1177 GCs

Fit split (6.3 mm OD) or splitless (6.5 mm OD) liners.

View Product Information

Cross-Disk Inlet Seals

for Thermo TRACE 1300/1310 GCs

All seals include washers. Ideal for high-flow split applications.

View Product Information

Replacement Inlet Seals

for Thermo TRACE 1300/1310 GCs

  • Gold plating provides inertness similar to fused silica.
  • All seals include washers.

View Product Information

Heater Block

for Agilent 6850/6890/7890 GC Split/Splitless Injector

Meets or exceeds original manufacturer’s performance.

View Product Information

Accessories

for ATAS LINEX DMI System

PTV Inlet Adaptor Kit

for Gerstel CIS 3 and CIS 4 PTV Inlets

  • Meets original manufacturer's performance.
  • Includes inlet adaptor, silver PTV seal, and slotted capillary nut.

View Product Information

Inlet Adaptor Kit for Dual Column Installation

for Agilent Capillary Injectors (Split/Splitless Fitting for Capillary Columns)

  • 1/16-inch split/splitless fitting that accepts standard, two-hole capillary ferrules.
  • Easier to install capillary columns due to the nut protruding farther from the insulated injection port chamber.
  • Same column insertion depth as the original manufacturer's equipment.
  • Kit includes adaptor fitting, 1/16" capillary nut, gold-plated 1.2 mm ID dual Vespel ring inlet seal, one 0.4 mm ID two-hole ferrule, and one 0.5 mm ID two-hole ferrule.

View Product Information

Hot Swap Capillary Column Nuts

for Agilent, PerkinElmer 590/690, and Thermo 1300/1310 GCs

  • No more burned fingers!
  • No more downtime waiting for injector parts to cool down.

View Product Information

The Claw and The Claw Holder Kit

  • Easily removes hot liners from injection ports.
  • 4 mL vials (not included) can be replaced when dirty.

View Product Information

Gold-Plated Liner Cap

for Split/Splitless Injector on Thermo Scientific TRACE, 8000, 8000 TOP & Focus SSL

Nut for Terminal Fitting

for Thermo Scientific TRACE GCs

Septum Cap

for Split/Splitless Injector on Thermo Scientific TRACE, 8000, 8000 TOP & Focus SSL

Make Life Easier (MLE) Capillary Tool Kit

for PerkinElmer GCs

Everything you need in one complete kit!

View Product Information

Make Life Easier (MLE) Capillary Tool Kit

for Bruker/Varian GCs

Everything you need in one complete kit!

View Product Information

Make Life Easier (MLE) Capillary Tool Kit

for Thermo Scientific GCs

Everything you need in one complete kit!

View Product Information

Make Life Easier (MLE) Capillary Tool Kit

for Shimadzu GCs

Everything you need in one complete kit!

View Product Information

Make Life Easier (MLE) Capillary Tool Kit

for Agilent GCs

Everything you need in one complete kit!

View Product Information

Capillary Installation Gauge

for Shimadzu 17A, 2010, 2014, and 2030 GCs

  • Seats ferrule* onto column for consistent installations.
  • Prevents crushed column ends.
  • Made from high-quality stainless steel.

View Product Information

Capillary Installation Gauge

for Bruker/Varian GCs for use with 1/16" ferrules

  • Seats ferrule* onto column for consistent installations.
  • Prevents crushed column ends.
  • Made from high-quality stainless steel.

View Product Information

Liner Cap Removing Tool

for Thermo Scientific GCs: Focus GC, TRACE GC Ultra & TRACE GC x GC

  • Easily loosens the liner cap from the injector.
  • Unique, ergonomic handleeasy to grip.

View Product Information

Adapters for Capillary Columns

for Thermo Scientific TRACE & Focus SSL

  • Use same installation distance as manufacturer's adaptors.
  • Made of high-quality stainless steel.
  • Siltek-treated version available for additional inertness.

View Product Information

Capillary Installation Gauge

for Thermo Scientific TRACE & Focus SSL (M4 Ferrules)

  • Seats ferrule* onto column for consistent installations.
  • Prevents crushed column ends.
  • Made from high-quality stainless steel.

View Product Information

Heater Block Retaining Nuts

for Agilent GC Split/Splitless Injectors

  • Aluminum construction.
  • Meet or exceed manufacturer's performance.

View Product Information

EPC Test Kit

for Agilent 6890 GCs

Kit includes three O-rings, two plugs, one mounting screw, and one test block.

View Product Information

Graphite O-Rings

for Shimadzu 2010, 2014, and 2030 GCs

Septum Nut

for Shimadzu 17A, 2010, 2014, and 2030 GCs

  • One-piece design for ease of installation and removal.
  • Made of clear anodized aluminum and high-quality stainless steel.

View Product Information

Graphite O-Rings

for PerkinElmer Auto SYS XL or Clarus 580/680 GCs with PSS Injector

Fits 4 mm OD liners.

View Product Information

Inlet Wrench

for Shimadzu 17A, 2010, 2014, and 2030 GCs

  • Designed specifically for removing Shimadzu injection ports.
  • High-quality stainless steel construction.

View Product Information

Heat Sink

for Agilent 5890 GC Split/Splitless Injector

Meets or exceeds original manufacturer’s performance.

View Product Information

Viton O-Rings

for Apex Liners

Liner Seals

for CIS4 and PTV

Heater Cartridge & Platinum Resistance Thermometer (PRT) Sensor

for Agilent 5890 GCs

  • Use with 5890 FID and split/splitless weldments.
  • Meets or exceeds original manufacturer's performance.

View Product Information

Capillary Installation Gauge

for Agilent 5973/5975/5977 MS

  • Seats ferrules onto column for consistent installations.
  • Made from high-quality stainless steel.

    Note: Do not use on a 5975/5977 MS with an EI source (inert or SS). Doing so will extend the column too far into the ion source. This installation gauge is compatible with the 5975 MS with a CI source and the 5977 MS with the extractor or high-efficiency sources.

View Product Information

Injection Port Repair Tool

for Agilent Split/Splitless Injection Ports

  • Remove contaminants, achieve a better seal.
  • Cleans critical inlet seal areas.

View Product Information

Inlet Liner Seals

for Thermo Scientific TRACE PTV

Max Temp: 450 °C

View Product Information

Rethreading Tool

for Agilent Split/Splitless Injection Ports

Worn and damaged threads can allow oxygen into the systemcompromising analytical results and destroying columns. The built-in guide helps prevent cross-threading.

View Product Information

Inlet Liner Packing Tool

  • Position wool reproducibly every time.
  • Accurate to a specific, measured depth.
  • Can be used with all manufacturers' liners.

View Product Information

Inlet Liner Removal Tool

  • Easily remove liner from injectorno more burned fingers.
  • Made from high-temperature silicone.
  • Won’t chip or crack the liner.

View Product Information

Capillary Installation Gauge

for Agilent GCs

  • Seats graphite* ferrules onto column for consistent installations.
  • Prevents crushed column ends.
  • Made from high-quality stainless steel.

View Product Information

CarboFrit Puller/Inserter Tool

  • Hook end for removing CarboFrit inserts.
  • Bent end (90°) for inserting CarboFrit inserts.

View Product Information

Backpressure Gas Regulator

Capillary GC inlet systems have backpressure regulators to maintain a constant upstream pressure and rapidly respond to catastrophic leaks. The 060 psig (0-414 kPa) operating range is sufficient to operate a 105 m, 0.25 mm ID column at its optimum flow rate.

View Product Information

Injector Nut Kit

for Shimadzu 17A, 2010, 2014, and 2030 GCs

Includes 17A injector nut, 0.4 mm graphite ferrule, and 1/16-inch stainless steel capillary nut.

View Product Information

Graphite O-Rings

for Agilent and Bruker/Varian 1177 Injectors

Excellent thermal stability at injection port temperatures up to 450 °C!

View Product Information

Injector/Detector Plug Nuts

for Agilent, PerkinElmer 590/690, and Thermo 1300/1310 GCs

  • Use to cap off an injector to isolate leaks.
  • Use to cap off a detector for thermal cleaning.
  • Use to check a detector or make-up gas flow rate.
  • Use to cap off a detector and prevent hydrogen from accidentally diffusing into the oven from an unused detector base.

View Product Information

Siltek Septum Packed Purge Port Weldment

for Agilent 5890 GCs

Siltek treatment makes weldment inert and eliminates adsorption of sensitive compounds (e.g., DDT and Endrin). Order Viton O-rings and appropriate septa separately.

View Product Information

1/8-Inch Capillary Inlet Adaptor Fitting Kit

Split/Splitless Fitting for 0.53 mm ID Capillary Columns

  • 1/8-inch split/splitless fitting accepts standard two-hole capillary ferrules and a standard 1/8-inch nut.
  • Makes column installation easy due to the nut protruding farther from the insulated injection port chamber.
  • The column insertion depth is the same as the original equipment.
  • Kit includes adaptor fitting, capillary nut, stainless steel inlet seal, washer, and one 0.8 mm ID two-hole ferrule.
  • Use recessed taper liners with this adaptor.

View Product Information

Direct Replacement Reducing Nut

for Agilent and PerkinElmer 590/690 GCs

  • Made from high-quality stainless steel.
  • Meets original manufacturer's equipment performance.

View Product Information

Replacement Chemical Traps and Parts

for Agilent GCs

  • Easy to install.
  • Attach to same fittings as original manufacturer's equipment.

View Product Information

60 psig Backpressure Regulator Kit

for Agilent GCs

Increase the versatility of your Agilent 5890 GC by replacing the existing 30 psig (207 kPa) backpressure regulator and gauge with our 60 psig (414 kPa) regulator. Enables you to use longer 60 m and 105 m columns as well as shorter 10 m columns. Includes complete instructions.

View Product Information

Cross-Disk Inlet Seals

for Agilent GCs

  • Ideal for high-flow split applications >500 mL/min on Agilent 5890 GCs.
  • Gold plating provides enhanced inertness versus stainless steel.
  • All seals include washers.

View Product Information

Replacement Inlet Seals

for Agilent GCs

  • Gold plating provides enhanced inertness versus stainless steel.
  • All seals include washers.

View Product Information

Mini Wool Puller/Inserter

Insert and remove wool plugs easily. Order a spare pack so you’ll always have one available.

View Product Information

Septum Puller

  • Use hooked end for removing septa and O-rings; pointed end works well for removing stuck ferrules or debris.
  • Keep several on hand in your laboratory for other uses, too.

View Product Information

PTV Liner Seal Pre-Seat Tool

for Gerstel CIS 3 and CIS 4 PTV Inlets

PTV Slotted Capillary Column Nut

for Gerstel CIS 3 and CIS 4 PTV Inlets

Replacement Parts for Injection Port Repair Tool

for Agilent Split/Splitless Injection Ports

Silver PTV Seals

for Agilent 6890 GCs

Septa Holder Kits

for Thermo Scientific TRACE, 8000, 8000 TOP & Focus SSL

  • Includes septum support and holder.
  • Made from high-quality stainless steel.
  • Silcosteel-AC-treated version helps with septum removal.

View Product Information

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us