Packed/Micropacked Column Inlet Supplies

Packed/Micropacked Column Inlet Supplies

Products

Packed Column Inlet Adaptor Kit for 1/4" Injection Ports

  • Use 1/8" and 3/16" OD columns in 1/4" on-column injection ports.
  • Centers column perfectly in injection port to eliminate bent syringe needles.
  • Slotted design prevents carrier gas occlusion.
  • Vespel/graphite reducing ferrules make installation easy.
  • Includes all nuts & ferrules used to attach tubing to the injector or detector.

View Product Information

Micropacked Inlet Conversion Kits

  • Convert a capillary GC split/splitless inlet for use with 1/16" OD micropacked columns.
  • For use with Agilent 5890, 6890, and 7890 GCs.
  • Sample pathways deactivated for ultimate inertness.

View Product Information

Uniliner Liner for 1/4-Inch Packed Injection Port Conversion

  • Reduces solvent tailing.
  • Versatile0.53 mm ID version can be used in the direct (DI) or on-column (OC) injection mode.
  • Incorporates a gentle taper that seals the column and reduces dead volume in direct injection mode.
  • Available in various designs.

View Product Information

Vu-Tight Installation Fittings Kit

Includes a 1/4-inch stainless steel nut and graphite ferrule for attaching the liner to the GC inlet and a 1/4 to 1/16-inch stainless steel reducer, plus a 1/4-inch and 0.5 mm ID graphite ferrule for attaching the column to the liner.

View Product Information

Dual Column mini-Lam Direct Injection Tee Kit for 1/4-inch packed column inlets

  • Inverted cup design offers complete sample vaporization.
  • Permits larger sample volumes.
  • Incorporates a Press-Tight taper in each outlet leg, to make a perfect, dead-volume-free connection to each analytical column (ODs ranging from 0.4 to 0.8 mm).
  • Allows visual confirmation of the column connection.
  • Open-top design makes it easy to pack with glass wool, keeping sample residue from contaminating the cup.

View Product Information

Cyclo Vu-Tight DI Liners, 1/4-inch OD

  • Visually observe the Press-Tight connection between the column end and liner.
  • Fit 0.32 and 0.53 mm ID capillary columns (column ODs from 0.5 mm to 0.8 mm).
  • Slotted top prevents obstruction of carrier gas flow.
  • Operate in the direct injection mode.

View Product Information

Vu-Tight DI Liners for 1/4-Inch Packed Injection Port Conversion

  • Visually observe the Press-Tight connection between the column end and liner.
  • Fit 0.32 and 0.53 mm ID capillary columns (column ODs from 0.5 mm to 0.8 mm).
  • Slotted top prevents obstruction of carrier gas flow.
  • Operate in the direct injection mode.

View Product Information

DI Liner Adaptor

for Agilent 5890 Packed Column GC

  • Uses standard 1/16-inch capillary nut and ferrules.
  • Convenient wrench pad at base.
  • Includes 1/4-inch graphite ferrule and stainless steel nut.
  • Use with Agilent or Restek DI glass inserts or Restek DI Uniliner liners for an Agilent 5890 packed column GC.

View Product Information

DI Uniliner Liners

for Agilent 5890 Packed Column GC

  • Press-Tight taper forms dead volume free connection to column.
  • Minimizes solvent and peak tailing.
  • Use with 0.25, 0.32, and 0.53 mm ID capillary columns.
  • Can be removed from the septum nut weldment.

View Product Information

DI Glass Inserts

for Agilent 5890 Packed Column GC

  • Tolerances closely controlled.
  • Can be removed from the septum nut weldment.

View Product Information

Dual Column Direct Injection Tee Kit for 1/4-inch packed column inlets

  • Designed with a glass spiral to promote sample vaporization and provide even sample distribution to the two columns.
  • Traps sample residue and minimizes the need for guard columns.
  • Press-Tight taper in each outlet leg facilitates a perfect dead-volume-free connection to each analytical column (OD 0.4 to 0.8 mm) and allows visual confirmation of the column connection.

View Product Information

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us