share:

Tools & Maintenance

Products

Dynamic Duo (Restek Leak Detector and ProFLOW 6000 Flowmeter)

Protect your instrument and improve data quality with this powerful pair from Restek. Checking for leaks and verifying flows before you start running help you avoid costly problems later.

View Product Information

Restek Electronic Leak Detector

New and improved! Prevent small leaks from causing big problems with a Restek leak detector.

  • Detects a broad range of gases and indicates leak severity with both an LED display and audible tone.
  • No more waiting for a full charge—can be operated during charging or used up to 12 hours between charges.
  • Charging kit includes both universal AC power adaptor and USB charging cable so you can charge anywhere, anytime.
  • Pinpoint very small gas leaks quickly and accurately before they cause damage and downtime.
  • Compact, handheld unit is easy to operate and convenient to use anywhere you need to check for leaks.

View Product Information

Restek ProFLOW 6000 Electronic Flowmeter

Flowmeters that can measure flammable gases are becoming mandatory due to the increased use of hydrogen in chromatography. With its Ex rating, the Restek ProFLOW 6000 meter is designed specifically with explosive and flammable gases in mind.

The Restek ProFLOW 6000 is the only flowmeter you need for any type of chromatography gas measurement because of its wide range of capabilities. The ProFLOW 6000 is an electronic meter capable of measuring volumetric flow for most gases. Real-time measurements can be made for various types of flow paths, including continually changing gas types. This portable unit is designed for easy handheld use, and the stand adds benchtop convenience.

View Product Information

Oven Shrouds

for Agilent 6890/7890 GCs

  • Includes heating coil and oven temperature sensor.
  • Available in 120 V and 220 V units.

View Product Information

Hi-Duty Tubing Cutter

  • Specifically designed to cut 1/8" to 1-1/8" (4 mm to 28 mm) OD tubing.
  • Easily cuts stainless steel, Monel alloy, and other hard-temper materials.
  • Unique design makes clean, right-angle cuts and eliminates spiraling.
  • Integral reamer folds away for safety and convenience.
  • Replacement cutter wheels also available.

View Product Information

FID Maintenance Kits

for Agilent GCs

  • Include the most common consumable GC supplies and tools.
  • All parts meet or exceed performance of instrument manufacturer's parts.
  • Parts list makes reordering easy.

View Product Information

GC-MS Cleaning Kit

Poor sensitivity, loss of sensitivity at high masses, or high multiplier gain during an auto tune are all indicators that your mass spectrometer source may need to be cleaned. Restek has assembled all of the necessary components for cleaning and polishing your ion source.

View Product Information

Oven Flapper Assemblies

for Agilent 5890/6890 GCs

  • Ensure even and consistent column heating when the insulation becomes damaged or worn.
  • Replacement Insulation Gasket and Hardware Kit includes the insulation gasket, 2 screws and 2 nuts.
  • Meets or exceeds original manufacturer's performance.
  • Insulation is replaceable, using Restek's Oven Flapper Assemblies.

View Product Information

Make Life Easier (MLE) Capillary Tool Kit

for PerkinElmer GCs

Everything you need in one complete kit!

View Product Information

Make Life Easier (MLE) Capillary Tool Kit

for Bruker/Varian GCs

Everything you need in one complete kit!

View Product Information

Make Life Easier (MLE) Capillary Tool Kit

for Thermo Scientific GCs

Everything you need in one complete kit!

View Product Information

Make Life Easier (MLE) Capillary Tool Kit

for Shimadzu GCs

Everything you need in one complete kit!

View Product Information

Make Life Easier (MLE) Capillary Tool Kit

for Agilent GCs

Everything you need in one complete kit!

View Product Information

12-Piece, Ball-Point Hex Key Set

Includes twelve hex keys (Allen wrenches): 0.050", 1/16", 5/64", 3/32", 7/64", 1/8", 9/64", 5/32", 3/16", 7/32", 1/4", and 5/16".

View Product Information

Flashlight

This high-power, 170-lumen LED light features a rotating magnetic clip that attaches securely to give you convenient, hands-free lighting in almost any location. The reinforced plastic body design is water- and impact-resistant, making it reliable and virtually indestructible.

View Product Information

Metric 9-Piece, Ball-Point Hex Key Set

Includes nine metric hex keys (Allen wrenches): 1.5, 2, 2.5, 3, 4, 5, 6, 8, and 10 mm.

View Product Information

Metric Wrench Set

High-quality 6 x 7 mm, 8 x 10 mm, and 16 x 17 mm wrenches for tightening a wide variety of fittings.

View Product Information

Open-End Wrench Set for use with Capillary Installation Gauge

for Shimadzu 17A, 2010, 2014, and 2030 GCs

Gap Inspection Gauge

  • Confirm that fittings are sufficiently tightened.
  • For use with 1/4", 3/8", 1/2" Swagelok fittings.
  • For Swagelok fittings in new installations only.

View Product Information

Tee Wrench

  • Hold 1/4" or 6 mm tee or cross fittings secure in multiple orientations during installation.
  • Fits easily in tool box, pouch, or belt.
  • Cushioned vinyl grip with generous gripping area.
  • For Swagelok fittings only.

View Product Information

Swaging Tool

  • Preswage compression fittings for easy installation.
  • Ideal for installations in tight areas.
  • For use with 1/4" Swagelok fittings only.

View Product Information

Flexible Inspection Light

  • Inspect inside surfaces of sample cylinders or other chambers.
  • 14" reach.
  • 100,000-hour LED life.

View Product Information

ResTape PTFE Tape

  • For threaded connections in a wide range of plumbing materials.
  • Each roll is 1/2" x 260".
  • Maximum temperature: 260 °C.

View Product Information

Torx Screwdriver Set

  • Set includes TR-10, TR-15, and TR-20.
  • Ideal for performing routine maintenance on Agilent 6890 and 7890 GCs.

View Product Information

GC Oven Thermometer

  • Verify GC oven temperature.
  • Quick measurements via sensor in the measuring tip.
  • Swivel head can turn 180°.
  • Wide measuring range: -50 °C to +350 °C.

View Product Information

SSI TC-20 Tube Cutting Machine

  • Cuts 1/16", 1/8", or 1/4" tubing with inside diameter as small as 0.008".
  • Electrically operated benchtop model.
  • Handy 1/16" dressing tool (included) on the swing arm removes burrs and reams tubing.
  • Voltage selectable 110120/220240 volts, 5060 Hz.*

View Product Information

Rethreading Tool

  • Repair worn or damaged threads.
  • Multiple uses (fittings, injectors, detectors, etc.)
  • Built-in guide to prevent cross threading.

View Product Information

GC Installation Kit

This kit contains the tubing and fittings needed to add an additional GC to your lab bench. Kit includes: tubing cutter, one 1/8-inch x 1/4-inch reamer, one 1/4-inch x 1/8-inch brass tube end reducer, one 7/16-inch wrench, one 1/2-inch wrench, four 1/8-inch brass tees, ten 1/8-inch brass nuts, ten brass front and back ferrules, and 50 feet (15.2 meters) of our instrument-grade cleaned 1/8-inch copper tubing.

View Product Information

Wrench Set

Includes 4-inch, 6-inch, and 8-inch adjustable wrenches.

View Product Information

5-in-1 Magnetic Screwdriver

Magnetic power tip holds bits and screws securely.

View Product Information

Plier Set

Includes 6-inch nose/side cutter, 6-inch wire cutter, and 6-inch adjusting pliers.

View Product Information

54-Piece Tool Kit

Set comes with screwdrivers, pliers, wrenches, sockets, scissors, clamps, and more. Durable, zippered, notebook-style carrying case for easy transport.

View Product Information

1/16-Inch Tubing Cutting Pliers

  • Ideal for cutting 1/16-inch tubing.
  • Cuts quickly, reducing distortion.
  • Perfect for quick cuts for non-critical applications or in "hard to get at" places.
  • After cutting, it is recommended that the dressing tool, cat.# 20188, be used to remove any burrs and to ream the tubing to a uniform shape.

View Product Information

Tubing Bender

  • Bends 1/8-inch, 3/16-inch, or 1/4-inch tubing.
  • Assists in making accurate left-hand, right-hand, or offset bends.

View Product Information

Tubing Reamer

  • Removes burrs from stainless steel tubing.
  • For 1/4- or 1/8-inch tubing.
  • Nonslip safety design.

View Product Information

Ridgid Tubing Cutter

  • Excellent for cutting 1/8- or 1/4-inch metal tubing.*
  • Compact size is ideal for tight spaces.
  • Replaceable cutting wheel.

View Product Information

1/16-Inch Tubing Cutter

  • Produces square, smooth cuts in 1/16-inch tubing.
  • Eliminates tubing distortion.
  • Cuts hard or soft copper, aluminum, brass, stainless steel, Monel alloy, or titanium.
  • Replaceable cutting wheel.

View Product Information

Universal Cylinder Wrench

Use this versatile wrench for tightening gauges and gas regulator CGA fittings to cylinder outlets and pipe thread connections.

View Product Information

Cylinder Valve Wrench

This specially designed wrench enables easy opening of cylinder valves that are fitted with a hand wheel. It is also suitable for removing difficult cylinder caps.

View Product Information

Replacement Cables

for Agilent GCs, Integrators, & Autosamplers

Connect an Agilent 5890 GC to remote-start another piece of equipment or to start the Agilent 5890 GC from that piece of equipment.

View Product Information

Replacement Cables

for Agilent GCs, Integrators, & Autosamplers

Connect an Agilent 5890 GC to a non-Agilent integrator or standard strip chart recorder.

View Product Information

Air Diverter

for Agilent GCs

  • Divert GC exhaust heat up and away from the lab bench.
  • Meets or exceeds original manufacturer's performance.
  • Easy to installno tools required.
  • Compatible with 4" flexible metal dryer hose.

View Product Information

FID/Injector Cleaning Kit

Use Restek’s Cleaning Kit with ANY injection port!

The FID/injector cleaning kit includes:
  • Nylon tube brushes (1/8", 3/16", 1/4").
  • Pipe cleaner.
  • Stainless steel tube brushes (3/8", 3/16", 1/4").
  • Stainless steel surface brush.
  • Stainless steel jet reamers.
  • Emery cloth.

View Product Information

FastPack Inlet Kits

for Agilent GCs

  • Convenient: all the parts you need in one packageno hunting for individual items.
  • Economical: costs less than the sum of the individual parts.
  • Clean: Mylar bag is factory sealed; no contamination of the products from weeks in the lab.

View Product Information

Ferrule Removal Kit

The tapered tools in this kit have teeth designed to grip and remove fused silica adaptor ferrules that have become stuck in the fitting detail. Each kit has two tools: one for removing 1/32-inch adaptor ferrules and one for removing 1/16-inch adaptor ferrules.

View Product Information

1/4-Inch3/16-Inch Open-End Wrenches

High-quality miniature wrenches to use with MXT low-dead-volume connectors.

View Product Information

Open-End Wrench Set

High-quality 1/4" x 5/16", 3/8" x 7/16", 7/16" x 1/2", and 1/2" x 9/16" wrenches for tightening a wide variety of chromatography fittings.

View Product Information

Nylon Tube Brushes and Pipe Cleaner

Use to remove small septum fragments and residue from dirty glass inlet liners. Brushes are 1/8-, 3/16-, and 1/4-inch in diameter; pipe cleaner is one foot (30 cm) long.

View Product Information

Stainless Steel Tube Brushes/Surface Brush

Unlike brass brushes that can leave a metal residue, these stainless steel tube brushes (3/8-, 3/16-, and 1/4-inch) work well for cleaning dirty collectors, injector ports, and detector ports. The surface brush can be used to remove residue that builds up on metal detector jets and electronic contacts.

View Product Information

Open-End Wrenches

High-quality wrenches for tightening capillary fittings.

View Product Information

4" Tapered Needle Files

These files can be used for many purposes. They are especially useful for removing ferrules that are lodged in injector or detector ports.

View Product Information

Mini Hand Drill Set

Drill ferrules to the proper ID in seconds! Includes three drills, for use with 0.25, 0.32, and 0.53 mm ID (0.4, 0.5, and 0.8 mm OD) capillary columns.

View Product Information

Soft-Side Storage Case for Restek ProFLOW 6000 Electronic Flowmeter or Leak Detector

Optional soft-side storage case is ideal for storing your flowmeter or leak detector in smaller spaces, such as your tool box.

View Product Information

Inlet Maintenance Kit

for Agilent GCs

  • Includes the most common consumable GC supplies and tools.
  • All parts meet or exceed performance of instrument manufacturer’s parts.
  • Parts list makes reordering easy.

View Product Information

Soap Film Bubble Flowmeter

  • 1 mL flowmeter for flows between 0.1 and 10 cc/min.
  • 50 mL flowmeter for flows between 10 and 300 cc/min.
  • Includes a reservoir bulb, twenty-four inches (60 cm) of 1/4-inch ID tubing, adaptor tubes for 1/8-inch tubing and 0.53 mm ID capillary columns, and Velcro fasteners.

View Product Information

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us