Instrument Accessories & Parts

Instrument Accessories & Parts

Products

Autosampler Preventive Maintenance Kit

for Agilent 1100, 1200 HPLC Systems

Pump PM Kit

for Agilent 1050, 1100, 1200 HPLC Systems

Preventive Maintenance (PM) Kits

for Waters HPLC & ACQUITY UPLC Systems

Instrument Replacement Parts

for Waters ACQUITY and nanoACQUITY Systems

Opti-Max Check Valves

  • Free-Turn housings can be removed with the tubing still attached, making maintenance fast while reducing fitting wear.
  • Rugged stainless steel cartridge bodies with ceramic ball and seat ensure longevity in harsh acetonitrile environments.
  • Every cartridge is tested to three bubbles of nitrogen/minute (industry standard is 12).
  • All balls and seats are individually matched.
  • Minimized ball travel distance delivers quicker seating for more accurate pump metering.

View Product Information

Metering Device Seal

for Agilent 1290 LC Samplers

Inlet Valve

for Agilent HPLC Systems

Passive Inlet Valve

for Agilent 1220, 1260 LC Systems

Line Filter

for Shimadzu LC Systems

Capillary Loop

for Agilent HPLC Systems

Diaphragm

for Shimadzu HPLC Systems

Outlet Cap & Gold Seal Assembly

for Agilent HPLC Systems

Caps and seals shipped unassembled.

Note: Not compatible for use with Outlet Cap and Gold Seal Assembly Tool (cat.# 24989).


View Product Information

Seal, Gold Disk (outlet)

for Agilent HPLC Systems

Note: Not compatible for use with Outlet Cap and Gold Seal Assembly Tool (cat.# 24989).

View Product Information

Pump Maintenance Kit

for Agilent 1100, 1200 HPLC Systems

Suction Filter

for Shimadzu HPLC Systems

Isolation Seal

for Agilent 1100, 1200 HPLC Systems

Stator Face Assembly

for Agilent HPLC Systems

Solvent Inlet Filter

for Agilent HPLC Systems

Standard Pump Seal Kit

for PerkinElmer HPLC Systems

Plunger Seals

for Thermo HPLC Systems

Syringe Assembly, 250 µL

for Thermo HPLC Systems

Note: Syringes and needles sold by Restek are intended for scientific research and laboratory use only and are not intended for human in vivo or animal use.

View Product Information

Rotor Seal Assembly, Rheodyne 7010

for Thermo HPLC Systems

Kel-F Washer

for Thermo HPLC Systems

Plunger Seal, Superseal

for Thermo HPLC Systems

Back-up Seal

for Thermo HPLC Systems

Piston

for Thermo HPLC Systems

Outlet Check Valve Assembly

for Thermo HPLC Systems

Inlet Check Valve Assembly

for Thermo HPLC Systems

Injector Lubricant

for Agilent HPLC Systems

Lamps

for Agilent HPLC Systems

Active Inlet Cartridge

for Agilent HPLC Systems

Bottle Head Assembly

for Agilent HPLC Systems

Connecting Tube

for Agilent HPLC Systems

Outlet Cap

for Agilent HPLC Systems

PTFE Frits

for Agilent HPLC Systems

Rotor Seals

for Agilent HPLC Systems

Needle Assembly

for Agilent HPLC Systems

Note: Syringes and needles sold by Restek are intended for scientific research and laboratory use only and are not intended for human in vivo or animal use.

View Product Information

Needle Seat Assembly

for Agilent HPLC Systems

Sapphire Pistons

for Agilent HPLC Systems

Wash Seal

for Agilent HPLC Systems

Seal Wash Kit

for Agilent HPLC Systems

Seal Wash Kit, Binary Pump

for Agilent HPLC Systems

Piston Seals

for Agilent HPLC Systems

Sieves for Outlet Valve

for Agilent HPLC Systems

Outlet Check Valves

for Agilent HPLC Systems

Seal Pack (Rebuilt - with Needle)

for Waters 717 Autosampler

Compression Screw

for Waters HPLC Systems

Face Seals Replacement Kit

for Waters HPLC Systems

Wash Tube Seal Kit

for Waters HPLC Systems

Wash Face Seal

for Waters HPLC Systems

Ferrule

for Waters HPLC Systems

Inlet Manifold Kit

for Waters HPLC Systems

Sapphire Plunger Assembly Kit

for Waters HPLC Systems

Sapphire Plungers

for Waters HPLC Systems

Insert Seal Parts Kit

for Waters HPLC Systems

Head Plunger Seal Kits

for Waters HPLC Systems

Seal Wash Plunger Seal

for Waters HPLC Systems

Plunger Seals

for Waters HPLC Systems

Super Seal for Analytical Heads

for Waters HPLC Systems

Check Valve Cartridges

for Waters HPLC Systems

Inlet Check Valve Assembly

for Waters HPLC Systems

Lamps

for Waters Detectors

Isolation Seal

for Waters HPLC Systems: Rheodyne Style

Vespel Rotor Seal

for Waters HPLC Systems: Rheodyne Style

ASI Replacement HPLC Pump Piston Rods

for Agilent HPLC Systems

Buffer salts and metals from the HPLC system become imbedded on the surface of the piston seal and gradually wear the surface of the piston rod. Worn regions on the rod will quickly destroy the pump seals. In turn, the seal material gets trapped on the frit at the head of the column, which leads to increased system pressure and/or irregular or poor peak shape. As the piston continues to wear, a leak may develop at the pump.

Any time piston seals are replaced, the piston rod should be inspected with a 10x magnifier or microscope to ensure it does not have wear or scratches. Replace the rod if you observe any glazed regions or scratches.


View Product Information

ASI Replacement HPLC Pump Piston Rods

for Waters HPLC Systems

Buffer salts and metals from the HPLC system become imbedded on the surface of the piston seal and gradually wear the surface of the piston rod. Worn regions on the rod will quickly destroy the pump seals. In turn, the seal material gets trapped on the frit at the head of the column, which leads to increased system pressure and/or irregular or poor peak shape. As the piston continues to wear, a leak may develop at the pump.

Any time piston seals are replaced, the piston rod should be inspected with a 10x magnifier or microscope to ensure it does not have wear or scratches. Replace the rod if you observe any glazed regions or scratches.


View Product Information

Deuterium Lamps

for Shimadzu HPLC Systems

Plunger Assembly

for Shimadzu HPLC Systems

Syringe

for Shimadzu HPLC Systems

Note: Syringes and needles sold by Restek are intended for scientific research and laboratory use only and are not intended for human in vivo or animal use.

View Product Information

Stator Assembly

for Shimadzu HPLC Systems

Rotor Seals

for Shimadzu LC Systems

Needle Seal

for Shimadzu HPLC Systems

Sapphire Plungers

for Shimadzu HPLC Systems

Plunger Rinse Seal

for Shimadzu HPLC Systems

Plunger Seals

for Shimadzu LC Systems

Outlet Check Valves

for Shimadzu LC Systems

Inlet Check Valves

for Shimadzu LC Systems

Deuterium Lamps

for PerkinElmer HPLC Systems

Needle

for PerkinElmer HPLC Systems

Note: Syringes and needles sold by Restek are intended for scientific research and laboratory use only and are not intended for human in vivo or animal use.

View Product Information

Low Pressure Seal

for PerkinElmer HPLC Systems

Standard High Pressure Seal

for PerkinElmer HPLC Systems

High Pressure Seal Kit

for PerkinElmer HPLC Systems

Outlet Check Valve

for PerkinElmer HPLC Systems

Inlet Check Valve

for PerkinElmer HPLC Systems

Outlet Cap & Gold Seal Assembly Tool

for Agilent 1050, 1100 HPLC Systems

Easily install the gold seal into the outlet cap.

For use with Agilent 5001-3701 gold disk seal only. Not compatible with Restek cat.# 25889 and 25890 (Agilent 5067-4728).


View Product Information

Capillary Stainless-Steel Tubing Assemblies

for Agilent HPLC Systems

  • Precut, micro-polished tubing and pre-seated fittings for quick, easy maintenance of your Agilent HPLC systems.
  • Meet or exceed manufacturer's performance.

View Product Information

ASI Piston Seals

for Agilent HPLC Systems

Over time the piston seal in every HPLC system becomes worn and must be replaced. Our piston seals are constructed of PTFE material with an additive that reduces their tendency to "cold flow" and improves their wear characteristics. PTFE seals are more resistant to any HPLC solvent than UHMWPE seals, but they are less wear-resistant and rugged. For Agilent 1050 and 1100 HPLC systems.

View Product Information

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us