Mobile Phase Accessories

Mobile Phase Accessories

Products

Waste Overflow Indicator for LC Systems

  • Avoid messy pooling around mobile phase waste containers.
  • Audible alarm instantly alerts user, preventing overflow.
  • Compact, battery-operated unit.
  • Available for 4-liter and GL-45 solvent bottles.

View Product Information

Hub-Cap Filter Kit for 4 L Bottles

Kit includes one each of: bottle adaptor; bottle adaptor nut; filter inlet cap; grid support; vacuum hose barb; tube compression fitting; 47 mm grid; 47 mm x 0.22 µm filter membrane; 47 mm x 0.45 µm filter membrane; 1/4" OD x 1/8" ID ultra-chemical resistant, FEP (fluorinated ethylene propylene)-lined Tygon tubing (3'); 6" x 6" box with shrink wrap insert.

Designed for 4 L bottles with GL-38 threads.

View Product Information

Hub-Cap Adaptors

Allow the use of the Mobi-Cap Top with 4-liter solvent bottles.

View Product Information

Mobi-Cap Adaptors

Allow the use of the Hub-Cap Top with GL-45 solvent bottles.

View Product Information

Mobi-Cap GL-45 Bottle Top Kits

  • Convenient kits for easy mobile phase management.
  • Protect your mobile phase from evaporation and contamination, and your lab from harmful vapors.
  • Includes one 3-port Mobi-Cap GL-45 bottle top (cat.# 27836).
  • Includes PTFE tubing 1/8" OD x 0.063 mm ID x 3 m (cat.# 27846).
  • Includes two 1/16" connection sparger filters: one 2 μm (cat.# 27827) and one 10 μm (cat.# 27828).
  • Available with or without safety-coated GL-45 bottle(s).
  • Use one 1/4-28 threaded port for exhaust filter or air inlet valve; other ports can be used as needed or closed with 1/4-28 plug (sold separately).

View Product Information

Mobi-Cap GL-45 Bottle Tops

  • Protect your mobile phase from evaporation and contamination, and your lab from harmful vapors.
  • Includes tubing connector nuts with color-sleeve adaptors and ferrules.
  • Use one 1/4-28 threaded port for exhaust filter or air inlet valve; other ports can be used as needed or closed with 1/4-28 plug (sold separately).

View Product Information

Eco-Cap GL-45 Bottle Tops

  • Economically protect your mobile phase from evaporation and contamination, and your lab from harmful vapors.
  • Order Hub-Cap adaptor (cat.# 26538) to allow use of Eco-Cap on 4-liter bottles.
  • Includes polypropylene male Luer plug.
  • No threading for fittings on the inside of the tubing ports; tubing is just inserted.

View Product Information

DEGASi Mobile Phase Degasser

Ultra-high degassing efficiency in a small, durable unit.

  • ZHCR patented control (variable RPM) maintains constant vacuum to eliminate baseline fluctuations.
  • Systec AF membrane is highly gas permeable, allowing a small 480 μL chamber volume for fast start-up and equilibration.
  • Flow path is biocompatible and offers broad chemical compatibility.
  • Continuous vacuum system monitoring to ensure optimum operational conditions are maintained.
  • Advanced error and leak-checking functions (refer to instruction manual).
  • Use with any HPLC system.
  • CE & RoHS compliant.

View Product Information

Bluestem Glass Solvent Filter

  • Restek Bluestem glass solvent filter provides clean mobile phase to extend the life of columns and pump seals.
  • 15 µm borosilicate glass frit sits lower than conventional glass filters to draw more mobile phase from each bottle.
  • Blue filter stem allows instant visual confirmation of upright filter orientation.
  • Connects to standard 1/8" OD (3.2 mm) PTFE tubing using your existing frit adaptor (also sold separately as cat.# 26392).

View Product Information

Hub-Cap 4-Liter Bottle Tops

Hub-Cap bottle tops are a great way to neatly keep your mobile phase lines where they belong. Use them instead of plastic paraffin film, aluminum foil, or tape on your mobile phase reservoirs.

View Product Information

Safety Exhaust Filter with Indicator

  • Breakthrough indicator changes from light pink to dark pink to notify you when to change filter.
  • Safety filter protects your lab from volatile compounds in waste bottles.
  • 1/4-28 threads for use on Mobi-Cap or Hub-Cap bottle tops.
  • Replace filter every 3 months or when indicator changes color; more frequently with rigorous use or use in harsh environments.

View Product Information

Mobile Phase Sparge Filters

  • Inexpensively prepare and maintain mobile phases free of dissolved oxygen, nitrogen, and other atmospheric gases.
  • Choose flangeless connector for either 1/16" or 1/8" OD tubing.
  • Filter elements available in 316 stainless steel or metal-free polyethylene (PE).
  • Connector made of PEEK, flangeless connector ferrule of ETFE (not in flow path).

View Product Information

Last Drop Mobile Phase Filter

  • Protect your instrument and column by filtering your mobile phase of contaminants and particulates.
  • Choose stepped connector for 1.5/2.2/3.5 mm ID tubing or flangeless connector for 1/8" OD tubing.
  • Filter elements available in 316 stainless steel or metal-free PTFE.
  • Housing made of PTFE, connector of PEEK, optional flangeless connector ferrule of ETFE (not in flow path).

View Product Information

Bottle Top Valves and Filters

  • Inlet valves protect your lab from volatile compounds; use with a filter to protect your mobile phase from bacterial contamination.
  • Outlet valve regulates pressure during helium sparging.
  • 1/4-28 threads for use on Mobi-Cap or Hub-Cap bottle tops.
  • Replace valves every 6 months and filters every 3 months; more frequently with rigorous use or use in harsh environments.

View Product Information

UHP Pulse Dampener

The UHP pulse dampener provides minimal flow pulsation at system pressures up to 18,000 psi. Its low dead volume (220 µL at atmospheric pressure) reduces overall system volume for UHP applications. The UHP pulse dampener has a stainless steel fluid path.

View Product Information

Ternary Tee Mixer

  • Reduced baseline noise.
  • Increased sensitivity.
  • Improved gradient accuracy for more reproducible results.
  • Increased reaction efficiency in post-column derivatization.
  • Stainless steel.

View Product Information

Sidewinder LC Heater/Cooler Temperature Control Module and Column Holder

  • Operation range: 555 °C, ±0.2 °C.
  • Ability to program multiple temperature points.
  • Accommodates columns up to 30 cm in length and 7.8 mm ID.
  • Compact design.

View Product Information

Sidewinder LC Column Heater

  • Easy to set up!
  • Operation range: 5 °C above ambient to 85 °C, ±1 °C.
  • Lightweight, compact design fits in small spaces.
  • Column holder can be placed in any orientation.

View Product Information

FlatLine Pulse Damper

  • Rupture-proof, no diaphragmminimal risk of failure or leaks.
  • Clean flush-out designno sample carryover.
  • Low internal volumenegligible effect on analyte bandwidth.

View Product Information

HyperShear Static In-Line Mixers

  • Reduced baseline noise.
  • Increased sensitivity.
  • Improved gradient accuracy for more reproducible results.
  • Increased reaction efficiency in post-column derivatization.
  • Stainless steel or PEEK.

View Product Information

QuickSplit Post-Column Flow Splitters

Fluid resistor technology eliminates adjustments to capillary tubing for optimizing split ratio. Wide range of interchangeable resistors available.

View Product Information

MiniPulse Pulse Dampener

  • Compact unit (2.5" x 1.5") can be placed almost anywhere.
  • Improve system baseline stability while minimizing dead volume (only 160 μL at atmospheric pressure).
  • Ideal for applications where minimizing the total system volume is critical.

View Product Information

Solvent Debubbler

Bubbles in an LC system can cause check valve malfunctions and pump cavitation, seriously affecting pump performance. The debubbler removes bubbles from the fluid stream before it enters the pump.

Special geometry at the base of the housing allows bubbles entrained in the inlet fluid stream to rise and be trapped in the reservoir. The gas/liquid interface is easily visible through the translucent wall of the device. Loosening the airtight cap releases the trapped gas. The debubbler features a polypropylene body and bracket; universal inlet and outlet connecting tips are made of 316 stainless steel and accept 0.063", 0.085", and 0.125" ID tubing.

View Product Information

High-Pressure Cup-Type In-Line Filter

This high-pressure cup-type filter can be used in fluid streams operating to 15,000 psi (103,421 kPa). The cup-shaped filter elements have a large (2.5 cm2) surface area to give long operating lifetime. Mounted in screw-type adapters, they are easily removed for cleaning. Normally, backflushing and cleaning in an ultrasonic bath with an appropriate solvent will restore them. If they become permanently clogged, replacement elements are available.
Housings and all wetted parts are 316 stainless steel. Filters are packaged with gland nuts and ferrules. A bulkhead type fitting is available for thru-panel mounting. Tubing 1/16" OD; connectorsCPI.

View Product Information

Membrane Microfiltration Glassware

This 47 mm filtration apparatus with fritted glass support is recommended for routine filtration of corrosive liquids and removal of particles from LC solvents. The ground joint connection eliminates phthalate contamination that can occur when using silicone or neoprene stoppers. The support base has a coarse-porosity glass frit and an integral vacuum connection, located above the drip tip to prevent contamination of the vacuum line with filtrate droplets. Each apparatus includes a funnel, an anodized aluminum clamp, a 47 mm fritted glass support base, and a filtration flask.

View Product Information

Low-Pressure CPI Inlet Filter for Mobile Phase Reservoir

A 316 stainless steel knurled cap and Tefzel CPI ferrule seal to 1/8" OD PTFE tubing when finger-tightened onto the precision-machined filter holder. The filter element is replaceable. Standard 10 µm porosity protects delicate pump components from particles but introduces very little pressure drop. 1/8" OD. May be used as a helium sparging diffuser.

View Product Information

Low-Pressure Slip-On Inlet Filter for Mobile Phase Reservoir

A 316 stainless steel tip with a Tefzel collar seals to a corrosion-resistant 316 stainless steel filter element. The slip-on filter easily attaches to the pump inlet line, without the use of wrenches. The universal 1/8" OD tip accommodates standard PTFE tubing inner diameters. The cylindrical filter is standard 10 µm porosity. Fits Altex, ISCO, LDC, Varian, Waters, PerkinElmer, and other pumps.

View Product Information

LO-Pulse Pulse Damper

The LO-Pulse Pulse Damper is a patented, wide-dynamic-range 316 stainless steel device that smooths pulsations and maintains constant flow at system pressures from 500 to 6,000 psi (3,447 to 41,369 kPa). The flow path volume is only 0.9 mL and the path is efficiently swept, eliminating solvent memory effects when changing mobile phases. Flow rate range of 0.01 to 100 mL/min.

The LO-Pulse pulse damper also is available in a space-saving, economical kit that includes hardware for mounting the pulse damper on a bracket, or for installing feet on it for bench-top use. Shipped with PEEK plugs. Includes nuts and ferrules for use with 1/16" tubing in the 10-32 coned inlet and outlet ports.

View Product Information

PTFE Tubing

  • Chemically inert tubing available in 0.094" and 0.063" IDs.
  • 1/8" OD in 3- and 10-meter lengths.
  • Easily cut to length using Clean-Cut Tubing Cutter (cat.# 25069).
  • Maximum temperature: 100 °C.
  • 1/4-28 threads for use on Mobi-Cap or Hub-Cap bottle tops.

View Product Information

Fittings and Ferrules for 1/8" & 1/16" Tubing

  • Ideal for safely and securely connecting PTFE tubing to Mobi-Cap bottle tops.

View Product Information

Restek Domestic Customer Service

Subject

Message