Tubing & Connections

Products

EXP Reusable Fittings for HPLC & UHPLC for 10-32 fittings and 1/16" tubing

EXP Hand-Tight Coupler

  • Hand-tight fitting style achieves effortless HPLC seals—no tools needed for a 8700+ psi seal.
  • Both hand-tight and hex-head styles wrench tighten for reliable UHPLC use up to 20,000+ psi!
  • Patented ferrule can be installed repeatedly without compromising high-pressure seal.
  • Hybrid design combines the durability of titanium with the sealing ability of PEEK.
  • Cutting-edge system provides ZDV (zero dead volume) connection to any 10-32 female port.
  • Compatible with 1/16" PEEK and stainless-steel tubing.

View Product Information

EXP Reusable Fittings for HPLC & UHPLC for 10-32 fittings and 1/16" tubing

EXP Hex-Head Fittings

  • Hand-tight fitting style achieves effortless HPLC seals—no tools needed for a 8700+ psi seal.
  • Both hand-tight and hex-head styles wrench tighten for reliable UHPLC use up to 20,000+ psi!
  • Patented ferrule can be installed repeatedly without compromising high-pressure seal.
  • Hybrid design combines the durability of titanium with the sealing ability of PEEK.
  • Cutting-edge system provides ZDV (zero dead volume) connection to any 10-32 female port.
  • Compatible with 1/16" PEEK and stainless-steel tubing.

View Product Information

EXP Reusable Fittings for HPLC & UHPLC for 10-32 fittings and 1/16" tubing

EXP Hand-Tight Fittings

  • Hand-tight fitting style achieves effortless HPLC seals—no tools needed for a 8700+ psi seal.
  • Both hand-tight and hex-head styles wrench tighten for reliable UHPLC use up to 20,000+ psi!
  • Patented ferrule can be installed repeatedly without compromising high-pressure seal.
  • Hybrid design combines the durability of titanium with the sealing ability of PEEK.
  • Cutting-edge system provides ZDV (zero dead volume) connection to any 10-32 female port.
  • Compatible with 1/16" PEEK and stainless-steel tubing.

View Product Information

EXP Reusable Fittings for HPLC & UHPLC for 10-32 fittings and 1/16" tubing

EXP Titanium Hybrid Replacement Ferrules

  • Hand-tight fitting style achieves effortless HPLC seals—no tools needed for a 8700+ psi seal.
  • Both hand-tight and hex-head styles wrench tighten for reliable UHPLC use up to 20,000+ psi!
  • Patented ferrule can be installed repeatedly without compromising high-pressure seal.
  • Hybrid design combines the durability of titanium with the sealing ability of PEEK.
  • Cutting-edge system provides ZDV (zero dead volume) connection to any 10-32 female port.
  • Compatible with 1/16" PEEK and stainless-steel tubing.

View Product Information

EXP2 Reusable Fittings for HPLC & UHPLC

for 10-32 fittings and 1/16" tubing

  • Unique nut driver allows easy 20,000+ psi seals without wrenches.*
  • Patented ferrule can be installed repeatedly without compromising high-pressure seal.
  • Precision design provides zero-dead-volume (ZDV) connection to any 10-32 port.
  • Compact design fits in tight spaces, perfect for small oven compartments and six-port injection valves.
  • Non-swaged ferrules mean vendor-specific tubing is not required.
  • Suitable for both HPLC and UHPLC.

*Rated to 20,000+ psi (1400 bar) and tested to 30,000 psi (2068 bar).


View Product Information

PTFE Tubing

  • Chemically inert tubing available in 0.094" and 0.063" IDs.
  • 1/8" OD in 3- and 10-meter lengths.
  • Easily cut to length using Clean-Cut Tubing Cutter (cat.# 25069).
  • Maximum temperature: 100 °C.
  • 1/4-28 threads for use on Mobi-Cap or Hub-Cap bottle tops.

View Product Information

Flexible Premium Grade Stainless Steel Tubing

  • Ideal for all plumbing in UHPLC systems.
  • 1/32" OD tubing with 17 mm long, 1/16" laser-welded ends.
  • Color bands for easy identification.
  • 316 stainless steel.
  • Tolerances: +/– 0.05 mm (.002") OD & +/– 0.025 mm (.001") ID.

View Product Information

Stainless Steel Tubing

  • Ideal for all plumbing in UHPLC systems.
  • 1/16" OD in 3- and 10-meter coiled lengths.
  • 316 stainless steel.
  • Standard-grade tolerances: +/– 0.05 mm (.002") OD & ID; premium-grade tolerances: +/– 0.05 mm (.002") OD & +/– 0.025 mm (.001") ID.

View Product Information

Stainless Steel Unions, Tees, and Crosses for UHPLC

  • Ideal for quickly and reliably connecting stainless steel tubing in UHPLC systems.
  • For 1/16" tubing on all 10-32 ports.
  • Body made of 316 stainless steel.
  • Includes 303 stainless steel nuts and 316 stainless steel ferrules.
  • Low dead volume.
  • Rated to 20,000 psi (1,375 bar).
  • 1/4" head on all nuts.

View Product Information

Stainless Steel Fittings for UHPLC

  • Ideal for connecting stainless steel tubing in UHPLC systems.
  • For 1/16" tubing on all 10-32 ports.
  • Ferrules must be purchased separately.
  • 1/4" head on all nuts.

View Product Information

PEEK Tubing

  • Ideal for plumbing to and inside HPLC systems.
  • 1/16" OD in 3- and 10-meter lengths.
  • Less oxygen permeable and more temperature resistant than PTFE or Tefzel tubing.
  • Easily cut to length using Clean-Cut Tubing Cutter (cat.# 25069).
  • Use with PEEK finger-tight or flangeless fittings.
  • Use tubing ≤ 0.007" to 7,000 psi; tubing ≥ 0.010" ID to 5,000 psi.

View Product Information

PEEK Unions, Tees, and Crosses for HPLC

  • Ideal for quickly and reliably connecting PEEK tubing in HPLC systems.
  • One-piece, finger-tight fittings—no ferrules required.
  • Low dead volume.
  • Included end fittings and body made of biocompatible PEEK.
  • Available in 0.25, 0.50, and 0.75 mm bore sizes.
  • Maximum temperature: 100 °C.
  • Rated to 5,000 psi (350 bar).
  • For 1/16" tubing on all 10-32 ports.

View Product Information

PEEK-HT Hex-Head Fittings for HPLC and UHPLC

  • One-piece design; no ferrule required.
  • Use included driver for wrench-free, 10,000 psi connections.
  • For 1/16" tubing on all 10-32 ports.
  • Made of proprietary, high-pressure, biocompatible PEEK.
  • Rated to 10,000 psi (689 bar).

View Product Information

PEEK Hex-Head Fittings for HPLC

  • One-piece design; no ferrule required.
  • For 1/16" tubing on all 10-32 ports.
  • Made of biocompatible PEEK.
  • Rated to 5,000 psi (350 bar).

View Product Information

PPS Hex-Head Fittings for HPLC

  • One-piece design; no ferrule required.
  • For 1/16" tubing on all 10-32 ports.
  • Made of polyphenylene sulfide (PPS).
  • Rated to 5,000 psi (350 bar).

View Product Information

PEEK Column Couplers

  • Connect two columns, a guard holder to a column, or inline sample prep holders.
  • One-piece, finger-tight design.
  • Self-adjusting to accommodate all 10-32 port depths.
  • Made of biocompatible PEEK.
  • Available in three IDs: 0.13, 0.17, or 0.25 mm.
  • Rated to 5,000 psi (350 bar).

View Product Information

Fittings and Ferrules for 1/8" & 1/16" Tubing

  • Ideal for safely and securely connecting PTFE tubing to Mobi-Cap bottle tops.
  • Easily cut to length using Clean-Cut Tubing Cutter (cat.# 25069).

View Product Information

LC Stainless Steel Capillary Tubing

  • 316-grade stainless steel.
  • Precise precut lengths.
  • Clean and smooth surface finish.
  • Color coded for easy identification.
  • Tight tolerance: OD and ID +/-0.001".

View Product Information

Capillary Stainless-Steel Tubing Assemblies

for Agilent HPLC Systems

  • Precut, micro-polished tubing and pre-seated fittings for quick, easy maintenance of your Agilent HPLC systems.
  • Meet or exceed manufacturer's performance.

View Product Information

Secure-Fit Fittings (Two Connectors)

A good connection between HPLC components is necessary for trouble-free chromatography. Secure-Fit connectors from Restek and Selerity Technologies ensure a consistent, leak-free seal—and they eliminate excess dead volume! An internal spring mechanism holds the capillary tubing at the proper depth in the female fitting. This seal is maintained while you finger-tighten the nut.

View Product Information

Secure-Fit Fittings (Single Connectors)

A good connection between HPLC components is necessary for trouble-free chromatography. Secure-Fit connectors from Restek and Selerity Technologies ensure a consistent, leak-free seal—and they eliminate excess dead volume! An internal spring mechanism holds the capillary tubing at the proper depth in the female fitting. This seal is maintained while you finger-tighten the nut.

View Product Information

Tubing Dressing Tool

Opens stainless steel tubing bore and removes burrs.

View Product Information

Clean-Cut Tubing Cutter

  • Burr-free, perpendicular cuts that will not distort the tubing OD or close the ID.
  • Use on PEEK, PTFE, Tefzel, and other polymeric tubing.
  • Individual holes for cutting 1/16", 2 mm, 3 mm, 1/8", and 4 mm tubing.

View Product Information

Universal 10-32 PEEK Column Connectors and Plugs

Universal PEEK connectors allow easy installation of all 1/16" tubing, including stainless steel, up to 5,000 psi (350 bar).

View Product Information

PEEK Tubing Elbows

Tubing elbows (90° and 180°) are ideal for routing 1/16" PEEK tubing through your system. Simply snap the tubing into the elbow. Prevent pinching of PEEK tubing, which can cause high pressure.

View Product Information

Tubing Clip

Securely holds 1/16" or 1/8" tubing in beaker, flask, or bottle up to 4 mm thick.

View Product Information

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us