share:

Gas Purification

Products

Click-On In-Line Super Clean Big Trap Replacement Filters

  • Largest-capacity traps available—run longer without replacing.
  • Maximum operating pressure of 11 bar (160 psig).
  • High-purity output ensures 99.9999% pure gas (maximum flow of 8 L/min).
  • Triple gas trap is ideal for purifying carrier gas.
  • Helium-specific triple gas trap is made for GC-MS—ready to use within 15 minutes of installation.
  • Hydrocarbon trap removes hydrocarbon contamination from carrier gas to help eliminate ghost peaks.
Note: Replacement filter only—fittings sold separately.

View Product Information

Click-On In-Line Super Clean Big Trap Filter Kits

  • Largest-capacity traps available—run longer without replacing.
  • "Quick connect" fittings with spring-loaded check valves allow filter replacement in seconds without tools or contamination.
  • Maximum operating pressure of 11 bar (160 psig).
  • High-purity output ensures 99.9999% pure gas (maximum flow of 8 L/min).
  • Triple gas trap is ideal for purifying carrier gas.
  • Helium-specific triple gas trap is made for GC-MS—ready to use within 15 minutes of installation.
  • Hydrocarbon trap removes hydrocarbon contamination from carrier gas to help eliminate ghost peaks.

View Product Information

Dynamic Duo (Restek Leak Detector and ProFLOW 6000 Flowmeter)

Protect your instrument and improve data quality with this powerful pair from Restek. Checking for leaks and verifying flows before you start running help you avoid costly problems later.

View Product Information

Restek ProFLOW 6000 Electronic Flowmeter

Flowmeters that can measure flammable gases are becoming mandatory due to the increased use of hydrogen in chromatography. With its Ex rating, the Restek ProFLOW 6000 meter is designed specifically with explosive and flammable gases in mind.

The Restek ProFLOW 6000 is the only flowmeter you need for any type of chromatography gas measurement because of its wide range of capabilities. The ProFLOW 6000 is an electronic meter capable of measuring volumetric flow for most gases. Real-time measurements can be made for various types of flow paths, including continually changing gas types. This portable unit is designed for easy handheld use, and the stand adds benchtop convenience.


View Product Information

Restek Electronic Leak Detector

New and improved! Prevent small leaks from causing big problems with a Restek leak detector.

  • Detects a broad range of gases and indicates leak severity with both an LED display and audible tone.
  • No more waiting for a full charge—can be operated during charging or used up to 12 hours between charges.
  • Charging kit includes both universal AC power adaptor and USB charging cable so you can charge anywhere, anytime.
  • Pinpoint very small gas leaks quickly and accurately before they cause damage and downtime.
  • Compact, handheld unit is easy to operate and convenient to use anywhere you need to check for leaks.

View Product Information

Click-On In-Line Super Clean Indicator

  • Oxygen: green to grey
  • Moisture: beige to clear

View Product Information

Click-On In-Line Super Clean Replacement Gas Traps

Note: Replacement trap only—fittings sold separately.

View Product Information

Restek Click-On In-Line Super Clean Gas Traps and Connector Kits

  • High-purity output ensures 99.9999% pure gas.
  • Click-On fittings for easy, leak-tight cartridge changes; brass or stainless steel, 1/4" or 1/8".
  • Triple gas trap is ideal for purifying carrier gas—it contains oxygen, moisture, and hydrocarbon scrubbers in one cartridge.
  • Fuel gas trap is ideal for purifying flame ionization detector (FID) fuel gases, removing both moisture and hydrocarbons.
  • Helium-specific triple gas trap is ideal for GC-MS—it contains oxygen, moisture, and hydrocarbon scrubbers in one cartridge.

View Product Information

Carbon Dioxide Trap

  • Removes carbon dioxide from inert gases He, Ar, N2, H2, and clean dry air (CDA) to low ppb levels.
  • Functions by consuming carbon dioxide in a reaction with highly dispersed NaOH on a silicate support (reaction produces water that remains adsorbed in the purifier).
  • In highly critical applications, consider using an additional moisture trap after the CO2 trap as a safety measure.

View Product Information

Indicating Detector Gas Purifier

  • Removes moisture and hydrocarbons (C5 and heavier) from dry air or inert gases.
  • Indicator signals breakthrough by changing from yellowish green to blue at low relative humidity to warn of leaks in the gas stream.
  • The inner glass tube contains activated carbon, moisture indicator, and molecular sieve.
  • 10 μm frits at both ends of the filter.
  • Heavy-walled inner glass tube is protected by a sealed outer plastic tube to further protect against leaks.

View Product Information

Indicating Carrier Gas Purifier

  • Removes multiple impurities such as O2, H2O, CO2, CO, halogenated compounds, siloxanes, hydrocarbons (heavier than butane), sulfur-containing molecules, and ammonia from inert gases (He, Ar, N2, and H2).
  • Can be used with other filters to provide endpoint detection.
  • Contains highly sensitive visual indicators for oxygen and water contamination. The oxygen indicator signals breakthrough when the adsorbent changes from green to grey, and the moisture indicator signals breakthrough by changing from blue to brown.
  • Heavy-walled inner glass tube is protected by a sealed outer plastic tube to further protect against leaks.

View Product Information

Electronic Maintenance Indicators for Gas Filters

  • Audiovisual warning system ensures maintenance is done on time.
  • Progressively displays gas filter status, preventing unplanned downtime for maintenance.
  • Can be custom configured to your replacement/maintenance schedule.

View Product Information

Restek Super Clean Ultra-High Capacity Oxygen Filter

Restek Super Clean ultra-high capacity oxygen filter cartridges feature easy-to-read indicators.

The indicator code is shown on every trap so there is no confusion determining when a trap needs to be replaced.


View Product Information

Restek Super Clean Ultra-High Capacity Moisture Filter

Restek Super Clean ultra-high capacity moisture filter cartridges feature easy-to-read indicators.

The indicator code is shown on every trap so there is no confusion determining when a trap needs to be replaced.


View Product Information

Click-On In-Line Super Clean Double Connector

Connects any Click-On trap to a Click-On indicator.

View Product Information

Click-On In-Line Super Clean Connectors

Click-On connectors allow you to change traps quickly, without introducing oxygen into your system.

View Product Information

Wall Mounting Bracket

Baseplates can be mounted by using screws and the mounting holes on the baseplate, or by using this optional wall mounting bracket.

View Product Information

Restek Super Clean Gas Trapping System for LC-MS

A Super Clean quick-change cartridge system efficiently removes hydrocarbons from nitrogen!
  • Designed for easy, hassle-free cartridge changes.
  • Up to 20 L of hydrocarbon-free nitrogen per minute.
  • Filters connected in parallel to handle high flows for LC-MS.

View Product Information

Gas Pressure Gauge Kit

  • Use an in-line pressure gauge to indicate when a thermal gas purifier getter tube should be replaced.
  • Includes 1/8" tee and 0–100 psi (0-689k Pa) gauge.

View Product Information

Replacement O-Rings for Cartridge Baseplates

Pack includes 10 large O-rings and 10 small O-rings.

View Product Information

Restek Super Clean Gas Filter Kits

  • High-purity output ensures 99.9999% pure gas (at max. flow of 2 L/min).
  • Designed for easy, hassle-free cartridge changes.
  • Glass inside to prevent diffusion; polycarbonate housing outside for safety.
  • The indicator code is shown on every trap so there is no confusion determining when a trap needs to be replaced.

View Product Information

Restek Filter Baseplates

  • End fittings available in brass or stainless steel.
  • Baseplates fit all stand-alone Super Clean gas filters offered.

View Product Information

Hydrocarbon S-Trap

  • Removes hydrocarbons and other contaminants.
  • Reduces organics to 0.1 ppm (assuming 100 ppm input).
  • Each individually activated to ensure maximum efficiency.
  • Fits in GC oven for easy thermal recharging.
  • Maximum operating pressure: 60 psi (414 kPa).

View Product Information

ECD Vent Trap

  • Reduces the release of hazardous materials from the ECD vent into the lab.
  • Includes connecting lines and mounting kit.

View Product Information

VICI Mat/Sen Gas-Specific Purifier Modules

  • Replace separate traps for removing impurities (e.g., moisture and hydrocarbons) with one multiple-bed purifier that is designed specifically for purifying helium, hydrogen, nitrogen, or air.
  • Reduce gas impurities from ppm to low ppb levels.
  • Decrease baseline noise and increase GC-MS sensitivity.
  • Pre-purged with the specified gas to shorten downtime.

View Product Information

High-Capacity Split Vent Trap

  • Reduces the release of hazardous materials from the capillary split vent into the lab.
  • Includes connecting lines and mounting kit.

View Product Information

Refillable Hydrocarbon Trap

  • Removes trace impurities from carrier gas.
  • Reduces organics to 0.1 ppm (assuming 100 ppm input).
  • 60 µm frit prevents gas contamination by purifier particles.
  • Good for purge-and-trap systems.
  • Refillable and rechargeable.
  • Maximum operating pressure: 125 psig (862 kPa).
  • Maximum flow: 5 L/min.

View Product Information

Capillary-Grade Hydrocarbon Trap

  • Packed with an extremely high surface area, baked coconut shell–based activated carbon.
  • Purged with ultra-high-purity helium; ready to use with any carrier gas including hydrogen.
  • Reduces organics to 0.1 ppm (assuming 100 ppm input).
  • Maximum operating pressure: 250 psi (1,724 kPa).

View Product Information

Indicating Moisture Trap

  • Reduces water to less than 10 ppb. Indicator changes from yellowish green to blue at 5% relative humidity (suitable for general use).
  • Pre-purged for fast stabilization.
  • Reduces noise from high-sensitivity detectors.
  • Heavy-walled glass body prevents oxygen and water infusion.
  • 10 μm frit prevents microparticulate damage to needle valves and flow controllers.
  • Maximum operating pressure: 100 psi (689 kPa).

View Product Information

High-Capacity Moisture Trap

  • Purged with ultra-high-purity helium; ready to use with any carrier gas including hydrogen.
  • Reduces water to less than 15 ppb.
  • Maximum operating pressure: 250 psi (1,724 kPa).
  • Maximum flow: 1.25 L/min.

View Product Information

Molecular Sieve S-Trap

  • Traps water vapor; increases column and oxygen trap lifetime.
  • Reduces baseline noise from sensitive detectors such as ECDs and mass spectrometers.
  • Activated and ready to use.
  • Reduces water to less than 1 ppm.
  • Maximum flow: 1 L/min.

View Product Information

High-Capacity Oxygen Trap

  • Removes up to 135 ml of oxygen or 2 g of water.
  • Long life—typically purifies more than 480 cu ft of inert gas.
  • Reduces oxygen to 15 ppb.
  • Maximum operating pressure: 250 psi (1,724 kPa).
  • Flow: 3 L/min @ 32 psi (221 kPa).

View Product Information

Replacement Chemical Traps and Parts

for Agilent GCs

  • Easy to install.
  • Attach to same fittings as original manufacturer's equipment.

View Product Information

Indicating Oxygen Trap

  • Removes oxygen to low ppb levels from He, Ar, N2, or methane.
  • Indicator changes from green to gray when adsorption capacity is depleted.
  • Can be used with nonoxidizing gases such as He, Ar, N2, H2, or CH4.
  • Heavy-walled inner glass tube is protected by a sealed outer plastic tube to prevent oxygen and water infusion.
  • Prepurged for fast stabilization.
  • 100 psi (689 kPa) maximum operating pressure.
  • Reduces oxygen to 100 ppb.
  • 10 µm frits at inlet and outlet.
  • Optimal flow rate: < 150 mL/min.

View Product Information

Restek Gas Management System

  • Removes moisture, hydrocarbons, and oxygen from carrier gas, extending column lifetime.
  • Produces high-purity carrier gas for most applications.
  • Includes one each: moisture, hydrocarbon, and indicating oxygen trap.
  • Replacing traps is safe and easy.
  • Maximum flow: 150 cc/min for optimal performance.

View Product Information

Charging Accessories for Restek Electronic Leak Detector (cat.# 28500)

For current leak detector model only (cat.# 28500); not compatible with legacy model (cat.# 22655).

View Product Information

Small Probe Adaptor for Restek Electronic Leak Detector

Compatible with both current (cat.# 28500) and legacy (cat.# 22655) leak detector models.

View Product Information

Replacement Gas Filters for Restek Super Clean Gas Filter Kits

  • High-purity output ensures 99.9999% pure gas (at max. flow of 2 L/min).
  • Designed for easy, hassle-free cartridge changes.
  • Glass inside to prevent diffusion; polycarbonate housing outside for safety.
  • The indicator code is shown on every trap so there is no confusion determining when a trap needs to be replaced.

View Product Information

Soft-Sided Storage Case for Restek Leak Detector or ProFLOW 6000 Electronic Flowmeter

Optional soft-sided storage case is ideal for storing your leak detector or flowmeter in smaller spaces, such as your toolbox.

Compatible with both current (cat.# 28500) and legacy (cat.# 22655) leak detector models.


View Product Information

Power Adaptors for Legacy Restek Electronic Leak Detector (cat.# 22655)

For legacy leak detector model only (cat.# 22655); not compatible with current model (cat.# 28500).

View Product Information

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us