Équivalence de colonnes GC
Colonnes par phase
Colonnes capillaires en silice fondue
Restek
|
Composition
de la phase |
Nomenclature
USP |
Agilent
|
SGE
|
Phenomenex
|
Machery-Nagel
|
Supelco
|
Quadrex
|
---|---|---|---|---|---|---|---|---|
diméthyle polysiloxane
|
G1, G2, G9, G38
|
HP-1, DB-1,
CP-Sil 5 CB |
BP1
|
ZB-1
|
OPTIMA 1
|
Equity 1, SPB-1
|
007-1
|
|
diméthyle polysiloxane
|
|
DB-1ht
|
|
ZB-1HT inferno
|
|
|
007-1HT
|
|
diméthyle polysiloxane
(faible "bleeding") |
G1, G2, G9, G38
|
HP-1ms,
HP-1ms UI, DB-1ms, DB-1ms UI, VF-1ms |
BP1
|
ZB-1ms
|
OPTIMA 1 MS, OPTIMA 1 MS, Accent
|
SLB-1ms
|
007-1MS
|
|
diphényle diméthyle polysiloxane
|
G27, G36
|
CP-Sil 8 CB, DB-5, HP-5
|
BP5
|
ZB-5
|
OPTIMA 5
|
Equity-5, SPB-5
|
007-5
|
|
diphényle diméthyle polysiloxane
|
G27, G36
|
CP-Sil 8 CB, DB-5, HP-5, HP-5ms, Ultra-2
|
|
ZB-5, ZB-5MS
|
|
Equity-5, SPB-5
|
|
|
diphényle diméthyle polysiloxane
|
G27, G36
|
DB-5ht,
VF-5ht |
HT5
|
ZB-5HTinferno
|
OPTIMA 5HT
|
|
007-5HT
|
|
diphényle diméthyle
polysiloxane (faible "bleeding") |
G27, G36
|
HP-5ms UI
|
BP5MS
|
ZB-5plus
|
OPTIMA 5 MS
|
SPB-5
|
007-5MS
|
|
1,4-bis(diméthylsiloxy) phényl- ene diméthyle polysiloxane
|
G27, G36
|
DB-5msUI
|
BPX5
|
ZM-5MS plus
|
OPTIMA 5 MS Accent
|
SLB-5ms
|
|
|
diphényle diméthyle polysiloxane
|
|
DB-XLB,
VF-Xms |
|
MR1, ZB-XLB
|
OPTIMA XLB
|
|
|
|
diphényle diméthyle polysiloxane
|
G32
|
|
|
|
|
SPB-20
|
007-20
|
|
Non communiqué
|
G42
|
HP-35, DB-35
|
|
ZB-35
|
|
SPB-35
|
007-35
|
|
phényle diméthyle polysiloxane
|
G42
|
VF-35ms
|
BPX35, BPX608
|
MR2
|
OPTIMA 35 MS
|
|
007-35MS
|
|
diphényle diméthyle polysiloxane
|
G3
|
HP-50+
|
|
|
|
SPB-50
|
007-17
|
|
Non communiqué
|
G3
|
DB-17
|
|
ZB-50
|
OPTIMA 17
|
|
|
|
diphényle diméthyle polysiloxane
|
G3
|
DB-17ms
|
BPX50
|
ZB-50
|
OPTIMA 17 MS
|
|
007-17MS
|
|
Non communiqué
|
|
|
|
|
|
|
007-65HT
|
|
silarylene-based cyano
|
G43
|
VF-624ms
|
BPX-Volatiles
|
ZB-624plus
|
|
|
007-502, 007-608, 007-624
|
|
Phase de polarité intermédiaire ; Crossbond
|
G43
|
VF-1301ms
|
|
ZB-624plus
|
|
|
007-502, 007-608, 007-624
|
|
Non communiqué. Phase de type 5.
|
|
|
|
|
|
|
|
|
cyanopropyle phényl diméthyle
polysiloxane |
G27, G36
|
DB-UI 8270D
|
|
ZB-Semivolatiles
|
|
|
|
|
cyanopropyle phényl diméthyle
polysiloxane |
G43
|
CP-Select 624 CB, DB-1301,
DB-624, DB-624UI, DB-Select 624UI |
BP624
|
ZB-624
|
OPTIMA 1301, OPTIMA 624
|
SPB-624
|
007-1301, 007-502,
007-624 |
|
trifluoropropyle méthyle polysiloxane
|
G46
|
CP-Sil 13 CB, DB-1701P,
DB-1701, VF-1701 Pesticides |
BP10
|
ZB-1701,
ZB-1701P |
OPTIMA 1701
|
Equity-1701
|
007-1701
|
|
trifluoropropyle méthyle polysiloxane (faible "bleeding")
|
G6
|
DB-210,
DB-200 |
|
|
OPTIMA 210
|
|
|
|
cyanopropyle méthyle phényleméthyle siloxane
|
G6
|
VF-200ms
|
|
|
|
|
|
|
Non communiqué
|
G7, G19
|
DB-225ms
|
BP225
|
|
OPTIMA 225
|
SPB-225
|
007-225
|
|
biscyanopropyle cyanopropyle phényle polysiloxane
|
Restek Innovation | |||||||
biscyanopropyle polysiloxane
|
G5, G8
|
VF-23ms
|
BPX70
|
|
|
SP-2330,
SP-2331, SP-2380 |
|
|
5% diphényle 95% diméthyle polysiloxane
|
G5
|
|
|
ZB-FAME
|
|
SP-2560
|
SLP-2560
|
|
Non communiqué
|
|
|
|
|
OPTIMA 5 Amine
|
|
|
|
polyéthylène glycol
|
G51
|
Restek Innovation
|
||||||
polyéthylène glycol
|
G16, G47
|
CP-Wax 52 CB, DB-Wax, DB-WAX UI
|
BP20
|
ZB-Wax
|
OPTIMA WAX
|
|
BRT-CW
|
|
polyéthylène glycol
|
G16
|
|
|
|
|
Omegawax
|
|
|
polyethylene glycol modified for acids
|
G16, G47
|
HP-INNOWax
|
|
ZB-WAXplus
|
|
SUPELCOWAX 10
|
007-CW
|
|
polyethylene glycol modified for bases
|
G25, G35
|
CP-FFAP CB, CP-Wax 58 FFAP CB, DB-FFAP, HP-FFAP, VF-DA
|
BP21
|
ZB-FFAP
|
OPTIMA FFAP, OPTIMA FFAP Plus, PERMABOND FFAP
|
Nukol
|
|
|
polyéthylène glycol
|
|
CAM, CP-Wax 51
|
|
|
FS-CW 20 M-AM
|
Carbowax Amine
|
|
|
polyethylene glycol
|
G16, G47
|
VF-WAX MS
|
|
|
|
SUPELCOWAX 10
|
007-CW
|
Colonnes métalliques MXT
Restek
|
Composition de la phase
|
Code USP
|
Agilent
|
SGE
|
Phenomenex
|
Machery-Nagel
|
Supelco
|
Quadrex
|
---|---|---|---|---|---|---|---|---|
diméthyle polysiloxane
|
G1, G2, G9, G38
|
DB-1,DB-PS1
|
BP1
|
UAC-1, UAC-1MS
|
||||
diméthyle polysiloxane
|
G1, G2, G9, G38
|
CP-SimDist
|
|
ZB-1XT SimDist
|
|
UAC-SIM
|
||
diphényle diméthyle polysiloxane
|
G27, G36
|
DB-PS5, VF-5ht UltiMetal
|
|
UAC-5, UAC-5MS
|
||||
phényle méthyle polysiloxane
|
G3
|
|
|
|
UAC-17
|
|||
diphényle diméthyle polysiloxane
|
|
CP-TAP-CB UltiMetal
|
|
|
UAC-65HT
|
|||
cyanopropyle phényle diméthyle
polysiloxane |
G43
|
DB-PS1301,
DB-PS624 |
UAC-624
|
|||||
cyanopropyle phényle diméthyle polysiloxane
|
G46
|
DB-PS1701
|
UAC-1701
|
|||||
trifluoropropyle méthyle polysiloxane
|
G6
|
|||||||
polyéthylène glycol
|
G16
|
CP-Wax 52-CB, DB-PSWAX
|
|
ZB--WAXplus
|
UAC-CW |
Colonnes PLOT
Restek
(Description de la phase) |
Code USP
|
Phase
|
Application
|
Agilent
(J&W, Varian, Chrompack) |
Supelco
|
Quadrex
|
---|---|---|---|---|---|---|
|
Oxyde d'aluminium
|
Hydrocarbones C1-C5, analyse de la pureté de l'éthylène, du propylène, des butènes, et des halocarbones
|
GS-Alumina,
CP-Al203/Na2SO4 |
Alumina-sulfate
|
|
|
|
Oxyde d'aluminium
|
Hydrocarbones C1-C5, analyse de la pureté de l'éthylène, du propylène, des butènes, et des halocarbones
|
CP-Al203/Na2SO4
|
Alumina-sulfate
|
|
|
|
Oxyde d'aluminium
|
Hydrocarbones C1-C8; isomères C1-C5, analyse de la pureté de l'éthylène, du propylène, du butène, et du butadiène
|
GS-Alumina KCl,
HP PLOT Al203, CP-Al203/KCl |
Alumina-chloride
|
||
|
Oxyde d'aluminium
|
Alcanes multi-halogénés, CFC (chlorofluorocarbons) en C1-C5
|
Produit unique |
|||
|
Oxyde d'aluminium
|
Analyse de traces de méthylacétylène, propadiène, et acetylène
|
Select Al203 MAPD
|
|
|
|
|
Oxyde d'aluminium
|
Analyse de traces de méthylacétylène, propadiène, et acetylène
|
|
|
|
|
|
Tamis moléculaire 5Å
|
Analyse de gaz permanents (He, Ne, Ar, O2, N2, Xe, Rn, CH4, et CO)
|
CP-Molsieve 5A, HP PLOT Molesieve
|
Molsieve 5A
|
PLT-5A
|
|
|
Tamis moléculaire 5Å
|
Analyse de gaz permanents (He, Ne, Ar, O2, N2, Xe, Rn, CH4, et CO)
|
|
|
||
Rt-Q-BOND (polymère poreux non polaire)
|
|
100% divinylbenzène
|
Forte rétention des composés volatils, CO2, soufrés de ppm et d'eau dans les solvants
|
HP PLOT Q,
PoraPLOT Q, PoraBOND Q |
Supel-Q-PLOT
|
PLT-Q
|
G45
|
100% divinylbenzène
|
Forte rétention des composés volatils, CO2, soufrés de ppm et d'eau dans les solvants
|
PoraPLOT Q, Ultimetal
|
|
PLT-Q
|
|
Rt-QS-BOND
[polymère poreux de polarité intermédiaire (polarité Q-BOND et S-BOND)] |
|
Polymère poreux de polarité intermédiaire
|
Neutral solvents, ketones, esters, and hydrocarbons; baseline separation of ethane, ethene, and acetylene
|
GS-Q
|
|
|
Rt-S-BOND
polymère poreux de polarité intermédiaire) |
|
Polymère DVB vinylpyridine
|
Séparation à la ligne de base de l'éthane, l'éthylène et le propylène ; ketones, esters, hydrocarbonés
|
PoraPLOT S
|
|
|
Rt-U-BOND
(polymère poreux polaire) |
|
Polymère DVB ethylèneglycol-diméthylacrylate
|
Plus grande rétention des composés polaires ; trace H2S, COS, and mercaptans in hydrocarbon streams
|
HP PLOT U,
PoraPLOT U, PoraBOND U |
|
|
Si vous travaillez sur d'autres applications, utilisez notre modélisateur de chromatogramme Pro EZGC pour trouver la colonne GC Restek la plus adaptée à votre liste d'analytes.