Restek
Home / Resource Hub / Technical Literature Library / PFAS Analysis by DIN EN 17892 for Drinking Water

PFAS Analysis by DIN EN 17892 for Drinking Water

articleBanner
  • Sample Matrix: drinking water
  • Sample Preparation: WAX and S-DVB solid-phase extraction
  • Detection Technique: LC-MS

Determination of the sum of perfluorinated substances (Sum of PFAS) in drinking water-Method using liquid chromatography/mass spectrometry (LC/MS)

DIN EN 17892 is used for the analysis of 29 PFAS in drinking water. It is not available from Restek but may be purchased from other sources. The full analyte list and recommended products for DIN EN 17892 are provided below. In addition, you can register and directly compare analyte lists and matrices across PFAS analysis methods here or visit www.restek.com/PFAS to explore our technical resources for PFAS analysis.

Analyte List for DIN EN 17892 for PFAS Analysis

PFAS acronyms, compound names, and CAS numbers vary across methods and guidelines, and they also depend on compound form (e.g., neutral vs. salt). The following list uses standardized terminology to allow easy comparison across the methods and guidelines in our comprehensive guide. Please refer to DIN EN 17892 for method-specific nomenclature.

Acronym PFAS Name CAS
NEtFOSAA N-Ethyl perfluorooctanesulfonamidoacetic acid 2991-50-6
PFBS Perfluoro-1-butanesulfonic acid 375-73-5
PFDA Perfluorodecanoic acid 335-76-2
PFDoA Perfluorododecanoic acid 307-55-1
PFHpA Perfluoroheptanoic acid 375-85-9
PFHxS Perfluoro-1-hexanesulfonic acid 355-46-4
PFHxA Perfluorohexanoic acid 307-24-4
PFNA Perfluorononanoic acid 375-95-1
PFOS Perfluorooctanesulfonic acid 1763-23-1
PFOA Perfluorooctanoic acid 335-67-1
PFTrDA Perfluorotridecanoic acid 72629-94-8
PFUnA Perfluoroundecanoic acid 2058-94-8
HFPO-DA, GenX Hexafluoropropylene oxide dimer acid 13252-13-6
PFBA Perfluorobutanoic acid 375-22-4
PFPeA Perfluoropentanoic acid 2706-90-3
PFDS Perfluoro-1-decanesulfonic acid 335-77-3
PFHpS Perfluoro-1-heptanesulfonic acid 375-92-8
PFPeS Perfluoro-1-pentanesulfonic acid 2706-91-4
FOSA Perfluoro-1-octanesulfonamide 754-91-6
4:2 FTSA (Sodium) 1H,1H,2H,2H-Perfluoro-1-hexanesulfonate 27619-93-8
6:2 FTS 1H,1H,2H,2H-Perfluorooctane sulfonic acid 27619-97-2
8:2 FTS 1H,1H,2H,2H-Perfluorodecane sulfonic acid 39108-34-4
9Cl-PF3ONS 9-Chlorohexadecafluoro-3-oxanonane-1-sulfonic acid (F-53B Major) 756426-58-1
ADONA 4,8-Dioxa-3H-perfluorononanoic acid 919005-14-4
PFNS Perfluoro-1-nonanesulfonic acid 68259-12-1
PFMPA Perfluoro-3-methoxypropanoic acid 377-73-1
PFDoS Perfluorododecane sulfonate 79780-39-5
PFUnDS Perfluoroundecane sulfonic acid 749786-16-1
PFTrDS Perfluorotridecane sulfonic acid 791563-89-8

 

Recommended Products for DIN EN 17892 for PFAS Analysis

ANALYSIS

Analytical LC Columns:

  • Raptor C18 SPP column: 2.7 μm, 100 x 2.1 mm (cat.# 9304A12) (listed in method appendix)
  • Force C18 FPP column: 1.8 μm, 100 x 3.0 mm (cat.# 963421E) (listed in method appendix)
  • Raptor C18 SPP column: 2.7 μm, 50 x 2.1 mm (cat.# 9304A52)
  • Force C18 FPP column: 1.8 μm, 50 x 2.1 mm (cat.# 9634252)

Delay Columns:

  • PFAS delay column: 5 µm, 50 x 2.1 mm (cat.# 27854)
  • PFAS delay column: 5 µm, 50 x 3.0 mm (cat.# 580959 [custom product])

Guard Columns:

  • UltraShield UHPLC precolumn filter: 0.2 µm frit (cat.# 25809)
  • EXP direct connect holder for EXP guard cartridges (cat.# 25808)
  • Raptor C18 EXP guard column cartridge: 2.7 µm, 5 x 2.1 mm (cat.# 9304A0252)

SAMPLE HANDLING

Sample Prep:

  • Resprep S-DVB SPE cartridge: 6 mL/500 mg (cat.# 28937)
  • Resprep polymeric SPE cartridge: WAX, 6 mL/500 mg, 30 µm (cat.# 28268)
  • Resprep polymeric SPE cartridge: WAX, 6 mL/200 mg, 30 µm (cat.# 28292)
  • Resprep polymeric SPE cartridge: WAX, 3 mL/60 mg, 30 µm (cat.# 28468)
  • Polypropylene sample reservoir: 75 mL (cat.# 26015)
  • Polypropylene connectors (cat.# 26007)
  • Q-sep multispeed centrifuge for QuEChERS (cat.# 28295)

Vacuum Manifolds:

  • Resprep QR-24 vacuum manifold (cat.# 28299-VM)
  • Resprep QR-12 vacuum manifold (cat.# 28298-VM)

Vacuum Pumps:

  • Chemker 300 PTFE vacuum pump: 20 L/min, AC110 V, 60 Hz (cat.# 27426)
  • Chemker 300 PTFE vacuum pump: 18 L/min, AC220 V, 50 Hz (cat.# 27427)

GENERAL LAB SUPPLIES

  • Polypropylene vials: 100-pk. (cat.# 23243)
  • Polypropylene vials: 1000-pk. (cat.# 23246)
  • Polyethylene vial caps: 100-pk. (cat.# 23244)
  • Polyethylene vial caps: 1000-pk. (cat.# 23247)
  • Centrifuge tubes: 50 mL, 50-pk. (cat.# 25846)
  • Centrifuge tubes: 50 mL, 500-pk. (cat.# 28290)
  • Norm-Ject plastic syringe: 10 mL Luer Lock tip (cat.# 22775)
  • Norm-Ject plastic syringe: 5 mL Luer Lock tip (cat.# 22774)

 

Discover More Solutions for PFAS Analysis!

 

Pro EZLC Chromatogram Modeler Develop PFAS Methods in minutes with our
Pro EZLC Chromatogram Modeler

EVAR4298A-UNV