PFAS Analysis by ISO 21675:2019 for Water

articleBanner
  • Sample Matrix: water containing <2 g/L solids
  • Sample Preparation: WAX solid-phase extraction
  • Detection Technique: LC-MS/MS

Determination of perfluoroalkyl and polyfluoroalkyl substances (PFAS) in water—Method using solid phase extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS)

ISO 21675:2019 is used for the analysis of 30 PFAS in water containing <2 g/L solids. It is not available from Restek but may be purchased from other sources. The full analyte list and recommended products for ISO 21675:2019 are provided below. In addition, you can register and directly compare analyte lists and matrices across PFAS analysis methods here or visit www.restek.com/PFAS to explore our technical resources for PFAS analysis.

Analyte List for ISO 21675:2019 for PFAS Analysis

PFAS acronyms, compound names, and CAS numbers vary across methods and guidelines, and they also depend on compound form (e.g., neutral vs. salt). The following list uses standardized terminology to allow easy comparison across the methods and guidelines in our comprehensive guide. Please refer to ISO 21675:2019 for method-specific nomenclature.

Acronym PFAS Name CAS
NEtFOSAA N-Ethyl perfluorooctanesulfonamidoacetic acid 2991-50-6
NMeFOSAA N-Methyl perfluorooctanesulfonamidoacetic acid 2355-31-9
PFBS Perfluoro-1-butanesulfonic acid 375-73-5
PFDA Perfluorodecanoic acid 335-76-2
PFDoA Perfluorododecanoic acid 307-55-1
PFHpA Perfluoroheptanoic acid 375-85-9
PFHxS Perfluoro-1-hexanesulfonic acid 355-46-4
PFHxA Perfluorohexanoic acid 307-24-4
PFNA Perfluorononanoic acid 375-95-1
PFOS Perfluorooctanesulfonic acid 1763-23-1
PFOA Perfluorooctanoic acid 335-67-1
PFTeDA Perfluorotetradecanoic acid 376-06-7
PFTrDA Perfluorotridecanoic acid 72629-94-8
PFUnA Perfluoroundecanoic acid 2058-94-8
HFPO-DA, GenX Hexafluoropropylene oxide dimer acid 13252-13-6
PFBA Perfluorobutanoic acid 375-22-4
PFPeA Perfluoropentanoic acid 2706-90-3
PFDS Perfluoro-1-decanesulfonic acid 335-77-3
PFHpS Perfluoro-1-heptanesulfonic acid 375-92-8
FOSA Perfluoro-1-octanesulfonamide 754-91-6
6:2 FTS 1H,1H,2H,2H-Perfluorooctane sulfonic acid 27619-97-2
8:2 FTS 1H,1H,2H,2H-Perfluorodecane sulfonic acid 39108-34-4
8:2 FTUCA, FOUEA 2H-Perfluoro-2-decenoic acid (8:2) 70887-84-2
8:2 diPAP 8:2 Polyfluoroalkyl phosphate diester 678-41-1
NMeFOSA N-Methylperfluorooctanesulfonamide 31506-32-8
NEtFOSA N-Ethylperfluorooctanesulfonamide 4151-50-2
PFHxDA Perfluoro-n-hexadecanoic acid 67905-19-5
PFODA Perfluoro-n-octadecanoic acid 16517-11-6
9Cl-PF3ONS 9-Chlorohexadecafluoro-3-oxanonane-1-sulfonic acid (F-53B Major) 756426-58-1
ADONA 4,8-Dioxa-3H-perfluorononanoic acid 919005-14-4

 

Recommended Products for ISO 21675:2019 for PFAS Analysis

ANALYSIS

Analytical LC Columns:

  • Raptor C18 SPP column: 2.7 μm, 50 x 2.1 mm (cat.# 9304A52)
  • Force C18 FPP column: 1.8 μm, 50 x 2.1 mm (cat.# 9634252)

Delay Columns:

  • PFAS delay column: 5 µm, 50 x 2.1 mm (cat.# 27854)
  • PFAS delay column: 5 µm, 50 x 3.0 mm (cat.# 580959 [custom product])

Guard Columns:

  • UltraShield UHPLC precolumn filter: 0.2 µm frit (cat.# 25809)
  • EXP direct connect holder for EXP guard cartridges (cat.# 25808)
  • Raptor C18 EXP guard column cartridge: 2.7 µm, 5 x 2.1 mm (cat.# 9304A0252)

SAMPLE HANDLING

Sample Prep:

  • 30 mm syringe filter: 0.45 µm, nylon (cat.# 23981)*
  • 30 mm syringe filter: 0.22 µm, nylon (cat.# 23980)*
  • Resprep polymeric SPE cartridge: WAX, 6 mL/500 mg, 30 µm (cat.# 28268)
  • Resprep polymeric SPE cartridge: WAX, 6 mL/200 mg, 30 µm (cat.# 28292)
  • Polypropylene sample reservoir: 75 mL (cat.# 26015)
  • Polypropylene connectors (cat.# 26007)
  • Q-sep multispeed centrifuge for QuEChERS (cat.# 28295)

*Note that a glass fiber filter is mentioned in the method. However, nylon and polypropylene are widely accepted filter membrane materials for PFAS analysis.

Vacuum Manifolds:

  • Resprep QR-24 vacuum manifold (cat.# 28299-VM)
  • Resprep QR-12 vacuum manifold (cat.# 28298-VM)

Vacuum Pumps:

  • Chemker 300 PTFE vacuum pump: 20 L/min, AC110 V, 60 Hz (cat.# 27426)
  • Chemker 300 PTFE vacuum pump: 18 L/min, AC220 V, 50 Hz (cat.# 27427)

GENERAL LAB SUPPLIES

  • Polypropylene vials: 100-pk. (cat.# 23243)
  • Polypropylene vials: 1000-pk. (cat.# 23246)
  • Polyethylene vial caps: 100-pk. (cat.# 23244)
  • Polyethylene vial caps: 1000-pk. (cat.# 23247)
  • Centrifuge tubes: 50 mL, 50-pk. (cat.# 25846)
  • Centrifuge tubes: 50 mL, 500-pk. (cat.# 28290)
  • Norm-Ject plastic syringe: 10 mL Luer Lock tip (cat.# 22775)
  • Norm-Ject plastic syringe: 5 mL Luer Lock tip (cat.# 22774)

 