PFAS Analysis Supporting U.S. EPA Rule UCMR 5 for Drinking Water

articleBanner
  • Sample Matrix: drinking water
  • Sample Preparation: samples for UCMR 5 testing are prepared and analyzed following EPA Methods 533 and 537.1 (WAX and S-DVB solid-phase extraction)
  • Detection Technique: LC-MS/MS

U.S. EPA Fifth Unregulated Contaminant Monitoring Rule (UCMR 5)

In the U.S., the fifth Unregulated Contaminant Monitoring Rule (UCMR 5) requires the monitoring of 30 contaminants (29 PFAS and lithium) in public drinking water systems. The Safe Drinking Water Act requires that UCMR 5 testing include all PFAS for which a drinking water method has been validated (and that are not subject to a National Primary Drinking Water Regulation); therefore, UCMR 5 includes all 29 PFAS that are within the scopes of EPA Methods 533 and 537.1. While both methods use a C18 column for LC-MS/MS analysis, they differ in sample preparation; 533 uses weak anion exchange (WAX) SPE cartridges, and 537.1 uses styrene-divinylbenzene (S-DVB) SPE cartridges. Both methods allow flexibility in specific areas and prohibit changes in others. The full analyte list and recommended products for PFAS analysis in drinking water for UCMR 5 samples are provided below. In addition, you can register and directly compare analyte lists and matrices across PFAS analysis methods here or visit www.restek.com/PFAS to explore our technical resources for PFAS analysis.

 

Analyte List for EPA UCMR 5 for PFAS Analysis

PFAS acronyms, compound names, and CAS numbers vary across methods and guidelines, and they also depend on compound form (e.g., neutral vs. salt). The following list uses standardized terminology to allow easy comparison across the methods and guidelines in our comprehensive guide. Please refer to U.S. EPA Rule UCMR 5 for method-specific nomenclature.

Acronym Compound Name CAS#
NEtFOSAA N-ethyl perfluorooctanesulfonamidoacetic acid 2991-50-6
NMeFOSAA N-methyl perfluorooctanesulfonamidoacetic acid 2355-31-9
PFBS Perfluoro-1-butanesulfonic acid 375-73-5
PFDA Perfluorodecanoic acid 335-76-2
PFDoA Perfluorododecanoic acid 307-55-1
PFHpA Perfluoroheptanoic acid 375-85-9
PFHxS Perfluoro-1-hexanesulfonic acid 355-46-4
PFHxA Perfluorohexanoic acid 307-24-4
PFNA Perfluorononanoic acid 375-95-1
PFOS Perfluorooctanesulfonic acid 1763-23-1
PFOA Perfluorooctanoic acid 335-67-1
PFTeDA Perfluorotetradecanoic acid 376-06-7
PFTrDA Perfluorotridecanoic acid 72629-94-8
PFUnA Perfluoroundecanoic acid 2058-94-8
HFPO-DA, GenX Hexafluoropropylene oxide dimer acid 13252-13-6
PFBA Perfluorobutanoic acid 375-22-4
PFPeA Perfluoropentanoic acid 2706-90-3
PFHpS Perfluoro-1-heptanesulfonic acid 375-92-8
PFPeS Perfluoro-1-pentanesulfonic acid 2706-91-4
4:2 FTS 1H,1H,2H,2H-Perfluorohexane sulfonic acid 757124-72-4
6:2 FTS 1H,1H,2H,2H-Perfluorooctane sulfonic acid 27619-97-2
8:2 FTS 1H,1H,2H,2H-Perfluorodecane sulfonic acid 39108-34-4
9Cl-PF3ONS 9-Chlorohexadecafluoro-3-oxanonane-1-sulfonic acid (F-53B Major) 756426-58-1
11Cl-PF3OUdS 11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (F-53B Minor) 763051-92-9
ADONA 4,8-Dioxa-3H-perfluorononanoic acid 919005-14-4
PFEESA Perfluoro(2-ethoxyethane)sulfonic acid 113507-82-7
NFDHA Nonafluoro-3,6-dioxaheptanoic acid 151772-58-6
PFMPA Perfluoro-3-methoxypropanoic acid 377-73-1
PFMBA Perfluoro-4-methoxybutanoic acid 863090-89-5

 

Recommended Products for EPA UCMR 5 for PFAS Analysis

ANALYSIS

Analytical LC Columns:

  • Raptor C18 SPP column: 50 x 2.1 mm, 2.7 μm (cat.# 9304A52)
  • Force C18 FPP column: 50 x 2.1 mm, 1.8 μm (cat.# 9634252)

Delay Columns:

  • PFAS delay column: 5 µm, 50 x 2.1 mm (cat.# 27854)
  • PFAS delay column: 5 µm, 50 x 3.0 mm (cat.# 580959 [custom product])

STANDARDS

  • EPA 537.1 PFAS calibration standard: 2 µg/mL, methanol (1 mM KOH) (cat.# 30735)
  • PFAS 24 calibration standard: 1 µg/mL, methanol (1 mM KOH/2-propanol [98:2]) (cat.# 30733)
  • PFAS 28 calibration standard: 1 µg/mL, methanol (1 mM KOH/2-propanol [98:2]) (cat.# 30734)

SAMPLE HANDLING

Sample Prep:

  • Resprep S-DVB SPE cartridge: 6 mL/500 mg (cat.# 28937)
  • Resprep polymeric SPE cartridge: WAX, 6 mL/500 mg, 30 µm (cat.# 28291)
  • Resprep polymeric SPE cartridge: WAX, 6 mL/200 mg, 30 µm (cat.# 28292)

Vacuum Manifolds:

  • Resprep QR-24 vacuum manifold (cat.# 28299-VM)
  • Resprep QR-12 vacuum manifold (cat.# 28298-VM)

Vacuum Pumps:

  • Chemker 300 PTFE vacuum pump: 20 L/min, AC110 V, 60 Hz (cat.# 27426)
  • Chemker 300 PTFE vacuum pump: 18 L/min, AC220 V, 50 Hz (cat.# 27427)

GENERAL LAB SUPPLIES

  • Polypropylene vials: 100-pk. (cat.# 23243)
  • Polypropylene vials: 1000-pk. (cat.# 23246)
  • Polyethylene vial caps: 100-pk. (cat.# 23244)
  • Polyethylene vial caps: 1000-pk. (cat.# 23247)
  • Centrifuge tubes: 50 mL, 50-pk. (cat.# 25846)
  • Centrifuge tubes: 50 mL, 500-pk. (cat.# 28290)
  • Norm-Ject plastic syringe: 10 mL Luer Lock tip (cat.# 22775)
  • Norm-Ject plastic syringe: 5 mL Luer Lock tip (cat.# 22774)

 