Roc HPLC Columns: The Reliable Cornerstone of Your LC Lab
Conventional HPLC columns built for solid performance, exceptional value, and compact storage.
- Conventional HPLC column built to be the cornerstone for your lab; pressure rated for any 400 bar HPLC system.
- Solid and reliable—delivers the peak shape, reproducibility, ruggedness, and performance you demand.
- Exceptional value for routine analyses and large-volume workflows—high-purity, fully porous silica backed by quality manufacturing features a variety of phases to fit most HPLC methods.
- Ideal for a wide range of applications from food to pharma; 5 phases cover 98% of USP methods.
- Newly designed minimal packaging for compact storage—download serial #-specific certificates of analysis at restek.com/documentation
Roc Family of HPLC Phases
USP Phase Code |
L1 |
L7 |
L11 |
L10 |
L3 |
Stationary Phase Category |
C18, octadecylsilane |
C8, octylsilane |
phenyl |
cyano |
bare silica |
Ligand Type |
monomeric C18 |
monomeric C8 |
phenyl-hexyl |
cyanopropyl |
n/a |
Particle Size |
3 μm or 5 μm, spherical |
3 μm or 5 μm, spherical |
3 μm or 5 μm, spherical |
3 μm or 5 μm, spherical |
3 μm or 5 μm, spherical |
Pore Size |
100 Å |
100 Å |
100 Å |
100 Å |
100 Å |
Surface Area |
300 m2/g |
300 m2/g |
300 m2/g |
300 m2/g |
300 m2/g |
Carbon Load |
20% |
12% |
15% |
8% |
n/a |
End-Cap |
yes |
yes |
yes |
yes |
n/a |
pH Range |
2.5 to 8.0 |
2.5 to 8.0 |
2.0 to 8.0 |
2.5 to 8.0 |
2.5 to 8.0 |
Maximum Temperature |
80 °C |
80 °C |
80 °C |
80 °C |
80 °C |
Roc HPLC Columns from Restek Perform Better Than or Equal To Columns from Other Vendors
Columns |
Analyte |
tR |
Area |
Height |
USP Tailing |
Asymmetry (10%) |
k' |
Plate Number |
Resolution |
Roc |
Ethylparaben |
3.252 |
1,407,609 |
281,358 |
1.176 |
1.148 |
1.182 |
9,738 |
12.5 |
Ethinyl Estradiol |
5.410 |
1,869,684 |
234,346 |
1.075 |
1.064 |
2.631 |
10,264 |
||
Vendor A |
Ethylparaben |
3.060 |
1,424,621 |
215,698 |
1.907 |
1.608 |
1.013 |
6,732 |
10.1 |
Ethinyl Estradiol |
4.889 |
1,860,659 |
223,879 |
1.311 |
1.217 |
2.217 |
8,575 |
||
Vendor B |
Ethylparaben |
2.873 |
1,426,068 |
319,850 |
1.143 |
1.124 |
0.866 |
9,706 |
9.9 |
Ethinyl Estradiol |
4.307 |
1,867,049 |
287,414 |
1.064 |
1.057 |
1.797 |
10,031 |
||
Vendor C |
Ethylparaben |
2.763 |
1,413,099 |
315,080 |
1.262 |
1.217 |
0.932 |
8,643 |
11.9 |
Ethinyl Estradiol |
4.580 |
1,868,724 |
270,662 |
1.143 |
1.122 |
2.203 |
9,700 |
||
Vendor D |
Ethylparaben |
3.157 |
2,939,187 |
357,541 |
1.159 |
0.965 |
1.084 |
4,478 |
12.2 |
Ethinyl Estradiol |
5.816 |
1,771,785 |
182,056 |
1.301 |
1.232 |
2.839 |
8,954 |
||
Vendor E |
Ethylparaben |
3.873 |
1,498,446 |
244,642 |
1.172 |
1.134 |
1.221 |
9,348 |
13.7 |
Ethinyl Estradiol |
6.839 |
1,781,453 |
174,955 |
1.080 |
1.063 |
2.921 |
9,963 |
Chromatographic conditions for Table I and Figure 4
All columns are C18 stationary phase (5 µm, 150 x 4.6 mm). Conditions are as follows. Mobile phase: water:acetonitrile (1:1); Flow rate: 1 mL/min; Injection volume: 25 µL; Instrument: HPLC with UV detector, 280 nm; Sample: 200 µg/mL ethinyl estradiol and 50 µg/mL ethylparaben in water:acetonitrile (1:1).