The Restek Biphenyl: Leading Resolution in LC since 2005

  • Separates a wider range of compounds than other phenyl and C18 chemistries.
  • Increases sensitivity and selectivity in LC-MS while using simple, MS-friendly mobile phases.
  • Restek’s most popular LC phase—available on traditional FPP and SPP core-shell silica.
The Restek Biphenyl - Leading Resolution in LC

Launched in 2005, the innovative Biphenyl (USP L11) is Restek’s most popular LC stationary phase because it is particularly adept at separating compounds that are hard to resolve or that elute early on C18 and other phenyl chemistries. As a result, rugged Biphenyl columns are extremely useful for fast separations—even with isobars—in drug, metabolite, and other analyses, especially those that require a mass spectrometer (MS). Increasing retention of early-eluting compounds can limit ionization suppression, and the Restek Biphenyl's heightened selectivity helps eliminate the need for complex mobile phases that are not well-suited for MS detection.

With ten years of unrivaled performance, Restek's time-tested Biphenyl has been proven to be the ideal column for clinical diagnostic, pain, pharma, and environmental labs seeking universal utility for mass spec applications. Restek was the first to bring you the benefits of the Biphenyl ligand, and our LC group has the veteran technical expertise to supply and support your lab better than anyone else.


The Restek Biphenyl is the Right LC Column in Any Format:

FEATURED
Raptor SPP Columns: A new species of column that combines the speed of superficially porous particles (SPP or “core-shell”) with time-tested Restek Biphenyl selectivity.


Force FPP Columns: Long-lasting, reproducible, and fully scalable FPP (fully porous particle) columns that let you easily transfer methods across your entire lab, from trusted-but-aged HPLCs to cutting-edge UHPLCs.


ALSO AVAILABLE
Ultra Columns: High-purity, type-B silica that minimizes activity and creates high-density bonding for reliable HPLC use.

Viva Columns: Rugged, spherical particles with a wide 300 Å pore size and narrow distribution that are designed for large-molecule separations.

DECONSTRUCTING THE BIPHENYL

With USLC technology, Restek's LC experts have defined our columns' selectivity based on molecular interactions. The more rings shown, the more significant a role played in solute retention. Learn more at www.restek.com/uslc

Properties:

  • Increased retention for dipolar, unsaturated, or conjugated solutes.
  • Enhanced selectivity when used with methanolic mobile phase.
  • Ideal for increasing sensitivity and selectivity in LC-MS analyses.

Switch to Biphenyl when:

  • Limited selectivity is observed on a C18.
  • You need to increase retention of hydrophilic aromatics.

Raptor Biphenyl LC Columns (USP L11)

  • Ideal for bioanalytical testing applications like drug and metabolite analyses.
  • Heightened selectivity and retention for compounds that are hard to resolve or elute early on C18 and other phenyl chemistries.
  • Limits ionization suppression and allows simple, MS-friendly mobile phases.
  • Part of Restek’s Raptor LC column line featuring 1.8, 2.7, and 5 µm SPP core-shell silica.

Force Biphenyl LC Columns (USP L11)

  • Ideal for bioanalytical testing applications like drug and metabolite analyses.
  • Heightened selectivity and retention for compounds that are hard to resolve or elute early on C18 and other phenyl chemistries.
  • Limits ionization suppression and allows simple, MS-friendly mobile phases.
  • Restek’s most popular LC stationary phase.

Ultra Biphenyl Columns (USP L11)

Stationary Phase Category: phenyl (L11)
Ligand Type: unique Biphenyl
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: 15%
End-Cap: yes
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Ultra Biphenyl Prep Columns

Our broadest selection of stationary phases, including unique phases. High-density bondings for maximum retention. High-purity, Type-B silica gives excellent peak shapes for a wide range of compounds.

Note: We strongly recommend ordering a semi-prep or prep column only after evaluating the desired separation on an equivalent analytical-scale column. Because we cannot reuse a column or the silica it contains once it has left our facility, we cannot accept returns of large-scale columns.

Viva Biphenyl Columns (USP L11)

Stationary Phase Category: phenyl (L11)
Ligand Type: Biphenyl
Particle: 5 µm, spherical
Pore Size: 300 Å
Carbon Load: 7%
End-Cap: yes
Surface Area: 100 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

EXP Direct Connect Holder

  • Free-Turn architecture lets you change cartridges by hand without breaking inlet/outlet fluid connectionsno tools needed.
  • Patented titanium hybrid ferrules can be installed repeatedly without compromising high-pressure seal.
  • Auto-adjusting design provides ZDV (zero dead volume) connection to any 10-32 female port.
  • EXP direct connect holder requires separate guard column cartridges; available from Restek in 2.1, 3.0, and 4.6 mm.

Raptor EXP Guard Column Cartridges

  • Free-Turn architecture lets you change cartridges by hand without breaking inlet/outlet fluid connectionsno tools needed.
  • Patented titanium hybrid ferrules can be installed repeatedly without compromising high-pressure seal.
  • Auto-adjusting design provides ZDV (zero dead volume) connection to any 10-32 female port.

Force EXP Guard Column Cartridges

  • Free-Turn architecture lets you change cartridges by hand without breaking inlet/outlet fluid connectionsno tools needed.
  • Patented titanium hybrid ferrules can be installed repeatedly without compromising high-pressure seal.
  • Auto-adjusting design provides ZDV (zero dead volume) connection to any 10-32 female port.

EXP Reusable Fittings for HPLC & UHPLC for 10-32 fittings and 1/16" tubing

EXP Hand-Tight Fittings

  • Hand-tight fitting style achieves effortless HPLC seals—no tools needed for a 8,700+ psi seal.
  • Both hand-tight and hex-head styles wrench tighten for reliable UHPLC use up to 20,000+ psi!
  • Patented ferrule can be installed repeatedly without compromising high-pressure seal.
  • Hybrid design combines the durability of titanium with the sealing ability of PEEK.
  • Cutting-edge system provides ZDV (zero dead volume) connection to any 10-32 female port.
  • Compatible with 1/16" PEEK and stainless steel tubing.

Ultra Guard Cartridges

Particle size: 5 µm spherical
Pore size: 100 Å

For a detailed description of the stationary phase in this guard cartridge, see the product page for an analytical column with the same silica and stationary phase (e.g., Ultra C18).

Viva Guard Cartridges

Particle size: 5 µm spherical
Pore size: 300 Å

For a detailed description of the stationary phase in this guard cartridge, see the product page for an analytical column with the same silica and stationary phase (e.g., Viva C18).

UltraShield UHPLC PreColumn Filter

  • Cost-effective protection for UHPLC systems.
  • Reliable way to filter out particulates and extend column lifetime.
  • Minimize extra column volume and maximize UHPLC sample throughput vs. guard cartridges.
  • Connects easily to any column with Parker-style ports; not compatible with Waters columns.
  • Leak tight to 15,000 psi (1,034 bar).
  • 0.5 µm or 0.2 µm stainless-steel frit in a stainless-steel body with PEEK ferrule.

Literature

Clinical, Forensic & Toxicology

Overcoming the Effects of Highly Organic Protein Precipitation Extracts on LC Peak Shape Using Direct Injection

Protein precipitation is frequently used to minimize matrix impact when analyzing biological samples. However, the effects of highly organic protein precipitation sample extracts on LC peak shape can negatively impact accurate quantification. Dilution or further sample preparation steps are often used to minimize these effects; however, here we show that direct injection of sample extracts is a viable option that can be used to prevent peak distortion, while avoiding the time and variability associated with additional sample preparation.

Clinical, Forensic & Toxicology

High-Throughput Analysis of Immunosuppressive Drugs from Whole Blood by LC-MS/MS

The success of organ transplant therapy depends in large part on the accurate and timely analysis of immunosuppressive drugs. In this study, we developed a fast, accurate method for cyclosporin A, tacrolimus, sirolimus, and everolimus in whole blood. The method pairs a single protein precipitation step with LC-MS/MS analysis using a Raptor Biphenyl column. A fast, 3-minute analysis time was obtained with no interference from matrix components. Excellent results were obtained for linearity, robustness, accuracy, and precision, demonstrating that the method is suitable for high-throughput therapeutic drug monitoring.

Clinical, Forensic & Toxicology

“The Big Pain”: Development of Pain-Free Methods for Analyzing 231 Multiclass Drugs and Metabolites by LC-MS/MS

As the demand for testing of pain management drugs increases, many laboratories are turning to LC-MS/MS for its increased speed, sensitivity, and specificity. The methods shown here use a Raptor Biphenyl column because it provides fast, accurate analysis of 231 drugs and drug metabolites.

Pharmaceutical

Novel Column Chemistry—High Impact, Low Cost Technology

Novel column chemistries are a simple change in an already budgeted consumable that can lead to optimized and more reliable methods—giving a fast return on a minimal investment.

Editorial

The Role of Selectivity in Liquid Chromatography Method Development

Dr. Schug, Associate Professor and Shimadzu Distinguished Professor of Analytical Chemistry in the Department of Chemistry and Biochemistry at The University of Texas at Arlington, discusses the role of column selectivity in liquid chromatography method development.

Foods, Flavors & Fragrances

Increase Data Quality for Sulfonamide Residue Analysis by HPLC and UHPLC Using Unique Biphenyl Column Selectivity

The unique selectivity and high retention of Biphenyl columns produce complete separation of sulfonamide residues and benefit both UV and MS detection. In addition, Biphenyl columns in a UHPLC format allow faster sample throughput when testing for these antibiotics.

Bioanalytical

A Rapid and Sensitive LC-MS/MS Method for the Analysis of Three Forms of Thyroid Hormones Using Raptor Biphenyl LC Columns

The Raptor Biphenyl column is excellent for rapid and sensitive analysis of thyroid hormones. With the method described here, concentrations of thyroid hormones as low as 2 pg/mL (T3) or 5 pg/mL (T4 and rT3) can be determined with less than 3.5 minutes of total analysis time. The analytical method is thus applicable to the clinical analysis of free thyroid hormone at low pg/mL levels.

PDF Document

Raptor Biphenyl LC Columns Brochure

Raptor LC columns combine the speed of superficially porous particles (i.e., SPP or “core-shell”) with the resolution of highly selective USLC technology. Featuring Restek's most popular LC stationary phase, the rugged Raptor Biphenyl is extremely useful for fast separations in bioanalytical testing applications like drug and metabolite analyses, especially those that require a mass spectrometer (MS). (PDF - 6MB)

PDF Document

Raptor Biphenyl LC Columns Sales Sheet

Fast, Rugged Raptor Columns with Time-Tested Selectivity: The industry-leading Biphenyl, first introduced by Restek in 2005, is our most popular LC stationary phase because it is particularly adept at separating compounds that are hard to resolve or that elute early on C18 and other phenyl chemistries. As a result, the rugged Raptor Biphenyl column is extremely useful for fast separations in bioanalytical testing applications like drug and metabolite analyses, especially those that require a mass spectrometer (MS). (PDF - 4MB)

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us