Restek
Accueil / Centre de ressources / Documentation technique / GC Column Cross-Reference

GC Column Cross-Reference

Columns by Phase

Fused Silica GC Columns

Restek
Phase
Description
USP
Nomen-
clature
Similar to Agilent
Similar to SGE    
Similar to Phenomenex
Similar to Machery-Nagel
Similar to Supelco
Similar to Quadrex
Rtx-1
dimethyl polysiloxane
G1, G2, G9, G38
HP-1, DB-1,
CP-Sil 5 CB
BP1
ZB-1
OPTIMA 1
Equity 1, SPB-1
007-1
Rxi-1HT
dimethyl polysiloxane
 
DB-1ht
 
ZB-1HT inferno
 
 
007-1HT
Rxi-1ms
dimethyl polysiloxane
(low bleed)
G1, G2, G9, G38
HP-1ms,
HP-1ms UI,
DB-1ms,
DB-1ms UI,
VF-1ms
BP1
ZB-1ms
OPTIMA 1 MS, OPTIMA 1 MS, Accent
SLB-1ms
007-1MS
Rtx-5
diphenyl dimethyl polysiloxane
G27, G36
CP-Sil 8 CB, DB-5, HP-5
BP5
ZB-5
OPTIMA 5
Equity-5, SPB-5
007-5
Rtx-5MS
diphenyl dimethyl polysiloxane
G27, G36
CP-Sil 8 CB, DB-5, HP-5, HP-5ms, Ultra-2
 
ZB-5, ZB-5MS
 
Equity-5, SPB-5
 
Rxi-5HT
diphenyl dimethyl polysiloxane
G27, G36
DB-5ht,
VF-5ht
HT5
ZB-5HTinferno
OPTIMA 5HT
 
007-5HT
Rxi-5ms
diphenyl dimethyl
polysiloxane
(low bleed)
G27, G36
HP-5ms UI
BP5MS
ZB-5plus
OPTIMA 5 MS
SPB-5
007-5MS
Rxi-5Sil MS
1,4-bis(dimethylsiloxy)
phenylene dimethyl
polysiloxane
G27, G36
DB-5msUI
BPX5
ZM-5MS plus
OPTIMA 5 MS Accent
SLB-5ms
 
Rxi-XLB
proprietary phase
 
DB-XLB,
VF-Xms
 
MR1, ZB-XLB
OPTIMA XLB
 
 
Rtx-20
diphenyl dimethyl
polysiloxane
G32
 
 
 
 
SPB-20
007-20
Rtx-35
diphenyl dimethyl
polysiloxane
G42
HP-35, DB-35
 
ZB-35
 
SPB-35
007-35
Rxi-35Sil MS
proprietary phase
G42
VF-35ms
BPX35, BPX608
MR2
OPTIMA 35 MS
 
007-35MS
Rtx-50
phenyl methyl
polysiloxane
G3
HP-50+
 
 
 
SPB-50
007-17
Rxi-17
diphenyl dimethyl
polysiloxane
G3
DB-17
 
ZB-50
OPTIMA 17
 
 
Rxi-17Sil MS
proprietary phase
G3
DB-17ms
BPX50
ZB-50
OPTIMA 17 MS
 
007-17MS
Rtx-65
diphenyl dimethyl
polysiloxane
 
 
 
 
 
 
007-65HT
Rxi-624Sil MS
proprietary phase
G43
VF-624ms
BPX-Volatiles
ZB-624plus
 
 
007-502, 007-608, 007-624
Rxi-1301Sil MS
silarylene-based cyano
G43
VF-1301ms
 
ZB-624plus
 
 
007-502, 007-608, 007-624
Rxi-LAO
midpolarity Crossbond phase
 
 
 
 
 
 
 
Rxi-SVOCms
Proprietary 5% phenyl-type phase
G27, G36
DB-5ms, DB-5ms UI, DB-UI 8270D
 
ZB-Semivolatiles
 
 
 
Rtx-1301
Rtx-624
cyanopropylmethyl phenylmethyl
polysiloxane
G43
CP-Select 624 CB, DB-1301,
DB-624,
DB-624UI,
DB-Select 624UI
BP624
ZB-624
OPTIMA 1301, OPTIMA 624
SPB-624
007-1301, 007-502,
007-624
Rtx-1701
cyanopropylmethyl phenylmethyl
polysiloxane
G46
CP-Sil 13 CB, DB-1701P,
DB-1701,
VF-1701 Pesticides
BP10
ZB-1701,
ZB-1701P
OPTIMA 1701
Equity-1701
007-1701
Rtx-200
trifluoropropylmethyl polysiloxane
G6
DB-210,
DB-200
 
 
OPTIMA 210
 
 
Rtx-200MS
trifluoropropylmethyl polysiloxane
(low bleed)
G6
VF-200ms
 
 
 
 
 
Rtx-225
cyanopropylmethyl phenylmethyl
polysiloxane
G7, G19
DB-225ms
BP225
 
OPTIMA 225
SPB-225
007-225
Rtx-440
proprietary phase
  Restek Innovation
Rtx-2330
biscyanopropyl cyanopropylphenyl
polysiloxane
G5, G8
VF-23ms
BPX70
 
 
SP-2330,
SP-2331,
SP-2380
 
Rt-2560
biscyanopropyl polysiloxane
G5
 
 
ZB-FAME
 
SP-2560
SLP-2560
Rtx-5 Amine
5% diphenyl 95% dimethyl polysiloxane
 
 
 
 
OPTIMA 5 Amine
 
 
Rxi-PAH
proprietary phase
G51
Restek Innovation
Rtx-Wax
polyethylene glycol
G16, G47
CP-Wax 52 CB, DB-Wax, DB-WAX UI
BP20
ZB-Wax
OPTIMA WAX
 
BRT-CW
FAMEWAX
polyethylene glycol
G16
 
 
 
 
Omegawax
 
Stabilwax
polyethylene glycol
G16, G47
HP-INNOWax
 
ZB-WAXplus
 
SUPELCOWAX 10
007-CW
Stabilwax-DA
polyethylene glycol modified for acids
G25, G35
CP-FFAP CB, CP-Wax 58 FFAP CB, DB-FFAP, HP-FFAP, VF-DA
BP21
ZB-FFAP
OPTIMA FFAP, OPTIMA FFAP Plus, PERMABOND FFAP
Nukol
 
Stabilwax-DB
polyethylene glycol modified for bases
 
CAM, CP-Wax 51
 
 
FS-CW 20 M-AM
Carbowax Amine
 
Stabilwax-MS
polyethylene glycol
G16, G47
VF-WAX MS
 
 
 
SUPELCOWAX 10
007-CW
 

MXT GC Columns

Restek
Phase
Description
USP
Nomen-
clature
Similar to Agilent
Similar to SGE    
Similar to Phenomenex
Similar to Machery-Nagel
Similar to Supelco
Similar to Quadrex
MXT-1
dimethyl polysiloxane
G1, G2, G9, G38
DB-1, DB-PS1
BP1
 
 
 
UAC-1, UAC-1MS
MXT-1HT SimDist
dimethyl polysiloxane
G1, G2, G9, G38
CP-SimDist
 
ZB-1XT SimDist
 
 
UAC-SIM
MXT-5
diphenyl dimethyl polysiloxane
G27, G36
DB-PS5, VF-5ht UltiMetal
 
 
 
 
UAC-5, UAC-5MS
MXT-50
phenyl methyl
polysiloxane
G3
 
 
 
 
 
UAC-17
MXT-65TG
diphenyl dimethyl polysiloxane
 
CP-TAP-CB Ultimetal
 
 
 
 
UAC-65HT
MXT-1301
cyanopropylmethyl phenylmethyl
polysiloxane
G43
DB-PS1301,
DB-PS624
 
 
 
 
UAC-624
MXT-1701
cyanopropylmethyl phenylmethyl
polysiloxane
G46
DB-PS1701
 
 
 
 
UAC-1701
MXT-200
trifluoropropylmethyl polysiloxane
G6
 
 
 
 
 
 
MXT-WAX
polyethylene glycol
G16
CP-Wax 52 CB, DB-PSWAX
 
ZB-WAXplus
 
 
UAC-CW
 

PLOT GC Columns

Restek
(Phase Description)
USP
Nomenclature
Porous
Layer
Application
Similar to Agilent
(J&W, Varian, Chrompack)
Similar to Supelco
Similar to Quadrex
Rt-Alumina BOND/Na2SO4
 
Aluminum oxide
C1-C5 hydrocarbons purity analysis of ethylene, propylene, butenes, and halocarbons
CP-Al203/Na2SO4,GS-Alumina
Alumina-sulfate
 
MXT-Alumina BOND/Na2SO4
 
Aluminum oxide
C1-C5 hydrocarbons purity analysis of ethylene, propylene, butenes, and halocarbons
CP-Al203/Na2SO4
 
 
Rt-Alumina BOND/KCl
 
Aluminum oxide
C1-C8 hydrocarbons; C1-C5 isomers purity analysis of ethylene, propylene, butene, and butadiene
GS-Alumina KCl,
HP PLOT Al203,
CP-Al203/KCl
Alumina-chloride
 
Rt-Alumina BOND/CFC
 
Aluminum oxide
Multi-halogenated alkanes, C1-C5 range chlorofluorocarbons (CFC)
Unique Product
Rt-Alumina BOND/MAPD
 
Aluminum oxide
Trace analysis of methyl acetylene, propadiene, and acetylene
Select Al203 MAPD
 
 
MXT-Alumina BOND/MAPD
 
Aluminum oxide
Trace analysis of methyl acetylene, propadiene, and acetylene
 
 
 
Rt-Msieve 5A
 
Molecular sieve 5A
Permanent gas analysis (He, Ne, Ar, O2, N2, Xe, Rn, CH4, and CO)
CP-Molsieve 5A, HP-PLOT Molesieve
Molsieve 5A
PLT-5A
MXT-Msieve 5A
 
Molecular sieve 5A
Permanent gas analysis (He, Ne, Ar, O2, N2, Xe, Rn, CH4, and CO)
 
 
 
Rt-Q-BOND
(nonpolar porous polymer)
 
100% Divinylbenzene
High retention for solvents, alcohols, polar volatiles, CO2, and ppm-level water in solvents
HP-PLOT Q, PoraBOND Q, PoraPLOT Q
Supel-Q-PLOT
PLT-Q
MXT-Q-BOND
(nonpolar porous polymer)
G45
100% Divinylbenzene
High retention for solvents, alcohols, polar volatiles, CO2, and ppm-level water in solvents
PoraPLOT Q,
Ultimetal
 
PLT-Q 
Rt-QS-BOND
[intermediate polarity porous polymer (polarity between Q-BOND and S-BOND)]
 
Intermediate polarity porous polymer
Neutral solvents, ketones, esters, and hydrocarbons; baseline separation of ethane, ethene, and acetylene
GS-Q
 
 
Rt-S-BOND
(intermediate polarity porous polymer)
 
DVB vinylpyridine polymer
Light gases in ethylene and propylene; ketones, esters, hydrocarbons
PoraPLOT S
 
 
Rt-U-BOND
(polar porous ploymer)
G45
DVB ethylene glycol-dimethylacrylate polymer
More retention for polar compounds; trace H2S, COS, and mercaptans in hydrocarbon streams
HP PLOT U,
PoraBOND U,
PoraPLOT U
 
 

If you’re running other applications, use our Pro EZGC Chromatogram Modeler to find the best Restek GC column for your analyte list.

GNOT3472B-UNV