Rxi-5Sil MS GC Capillary Column, 30 m, 0.25 mm ID, 0.25 µm, 5.0" Cage for Agilent 6850 GC
Rxi-5Sil MS GC Capillary Column, 30 m, 0.25 mm ID, 0.25 µm, 5.0" Cage for Agilent 6850 GC
Rxi-5Sil MS GC Capillary Column, 30 m, 0.25 mm ID, 0.25 µm, 5.0" Cage for Agilent 6850 GC
Rxi-5Sil MS GC Capillary Column, 30 m, 0.25 mm ID, 0.25 µm, 5.0" Cage for Agilent 6850 GC
  1. Rxi-5Sil MS GC Capillary Column, 30 m, 0.25 mm ID, 0.25 µm, 5.0" Cage for Agilent 6850 GC
  2. Rxi-5Sil MS GC Capillary Column, 30 m, 0.25 mm ID, 0.25 µm, 5.0" Cage for Agilent 6850 GC
  3. Rxi-5Sil MS GC Capillary Column, 30 m, 0.25 mm ID, 0.25 µm, 5.0" Cage for Agilent 6850 GC
  4. Rxi-5Sil MS GC Capillary Column, 30 m, 0.25 mm ID, 0.25 µm, 5.0" Cage for Agilent 6850 GC

Restek

Rxi-5Sil MS GC Capillary Column, 30 m, 0.25 mm ID, 0.25 µm, 5.0" Cage for Agilent 6850 GC

Catalog No. 13623-6850
US$782.00
Ordering Note

The certificates of analysis (CofAs) for fused silica, MXT, and PLOT analytical GC columns manufactured after December 2024 will be paperless. After that time, these digital CofAs can be accessed at www.restek.com/documentation.

Custom lengths and film thicknesses available. Contact Technical Service or your local Restek representative.

Rxi-5Sil MS GC Capillary Column, 30 m, 0.25 mm ID, 0.25 µm, 5.0" Cage for Agilent 6850 GC

Rxi-5Sil MS GC Capillary Column, 30 m, 0.25 mm ID, 0.25 µm, 5.0" Cage for Agilent 6850 GC

US$782.00

Overview

Features & Benefits
  • Fits Agilent 6850 GCs.
  • General-purpose columns for GC-MS analysis of most semivolatiles, polycyclic aromatic compounds, chlorinated hydrocarbons, phthalates, phenols, amines, organochlorine pesticides, organophosphorus pesticides, drugs, solvent impurities, and hydrocarbons.
  • Engineered to be a low-bleed GC-MS column.
  • Excellent inertness for active compounds.
  • Temperature range: -60 °C to 350 °C.
  • Some dimensions also available as Integra-Guard columns — a guard and analytical column in one to eliminate connection problems!
Description
The Rxi-5Sil MS stationary phase incorporates phenyl groups in the polymer backbone. This improves thermal stability, reduces bleed, and makes the phase less prone to oxidation. Rxi-5Sil MS columns are ideal for GC-MS applications.

Specifications

Product Specifications
Catalog No.
13623-6850
Product Name
Rxi-5Sil MS GC Capillary Column, 30 m, 0.25 mm ID, 0.25 µm, 5.0" Cage for Agilent 6850 GC