Restek
Home / Air & Gas Sampling / Sample Cylinders & Accessories / Cylinder Valves & Rupture Disks / 1/4" Male NPT x 1/4" Male NPT w/4-1/2" Dip Tube Sample Cylinder Valve, 3500 psig DOT Pressure Rating, Sulfinert Treated
Restek
1/4" Male NPT x 1/4" Male NPT w/4-1/2" Dip Tube Sample Cylinder Valve, 3500 psig DOT Pressure Rating, Sulfinert Treated
  1. 1/4" Male NPT x 1/4" Male NPT w/4-1/2" Dip Tube Sample Cylinder Valve, 3500 psig DOT Pressure Rating, Sulfinert Treated

1/4" Male NPT x 1/4" Male NPT w/4-1/2" Dip Tube Sample Cylinder Valve, 3500 psig DOT Pressure Rating, Sulfinert Treated

Catalog No. 21402-11
US$389.00
Ordering Note

To order a sample cylinder valve with a custom length dip tube, please contact Customer Service or your local Restek representative. Specify dip tube length when ordering (maximum length = 5.25"/13.3 cm). Note: End of part will not be treated after cutting tube to length.

1/4" Male NPT x 1/4" Male NPT w/4-1/2" Dip Tube Sample Cylinder Valve, 3500 psig DOT Pressure Rating, Sulfinert Treated

1/4" Male NPT x 1/4" Male NPT w/4-1/2" Dip Tube Sample Cylinder Valve, 3500 psig DOT Pressure Rating, Sulfinert Treated

US$389.00

Overview

Features & Benefits
  • Multiple valve configurations, including dip tube and rupture disks.
  • Large, durable, PCTFE or PTFE seat with steel insert ensures leak-free operation.
  • Temperature range: –30 °C to 120 °C
  • 303 stainless steel.
Description

Alta-Robbins's unique valve design incorporates a fully contained soft seat that provides durability and longer lifetime. Tight shut-off is easily achieved with very low torque, yet the valve is rugged enough to withstand overtightening.

Multiple valve configurations are available for both high-pressure and ultra-high-pressure sample cylinders. An outage tube or dip tube provides a headspace above liquefied gases so that, should expansion occur with an increase in temperature, the pressure is not dramatically increased. Outage is expressed as a percent of the total cylinder volume, based on the ratio of the length of headspace to the total length of the cylinder, with a maximum available outage of 50%. The dip tube is welded directly to the male inlet of the valve and cut to a length of up to 5.25 inches. Rupture disks function to protect sample cylinders from overpressurization by venting to the atmosphere. The pressure rating on the rupture disk should always be lower than the cylinder.

Specifications

Product Specifications
Catalog No.
21402-11
Product Name
1/4" Male NPT x 1/4" Male NPT w/4-1/2" Dip Tube Sample Cylinder Valve, 3500 psig DOT Pressure Rating, Sulfinert Treated