New York Pesticide Kit, 1 mL/ampul, 8 ampuls/kit
New York Pesticide Kit, 1 mL/ampul, 8 ampuls/kit
Overview
- 70-component kit provides analytical flexibility for constructing calibration curves or spiking sample matrices—saving time and reducing cost.
- Designed to create a high concentration working standard when all ampuls are combined.
- Two independently produced lots available.
- Verified composition and stability ensures long-lasting shelf life.
- Formulated for New York cannabis regulations; can be used to meet other government or in-house method requirements.
Contains 1 ampul of each of the following. 1 mL/ampul
Cat.# 32606: New York Pesticide Standard #1
Compound | CAS# |
Acephate | 30560-19-1 |
Aldicarb | 116-06-3 |
Bifenazate | 149877-41-8 |
Carbaryl (Sevin) | 63-25-2 |
Carbofuran | 1563-66-2 |
Chlorpyrifos | 2921-88-2 |
Coumaphos | 56-72-4 |
Diazinon | 333-41-5 |
Dichlorvos (DDVP) | 62-73-7 |
Dimethoate | 60-51-5 |
Ethoprophos | 13194-48-4 |
Fenoxycarb | 72490-01-8 |
Malathion | 121-75-5 |
Methiocarb | 2032-65-7 |
Methomyl | 16752-77-5 |
Methyl parathion | 298-00-0 |
Mevinphos | 7786-34-7 |
Naled | 300-76-5 |
Oxamyl | 23135-22-0 |
Phosmet | 732-11-6 |
Propoxur (Baygon) | 114-26-1 |
Cat.# 32607: New York Pesticide Standard #2
Compound | CAS# |
Abamectin | 71751-41-2 |
Acequinocyl | 57960-19-7 |
Bifenthrin | 82657-04-3 |
Cyfluthrin | 68359-37-5 |
Cypermethrin | 52315-07-8 |
Etofenprox | 80844-07-1 |
Permethrin (cis & trans) | 52645-53-1 |
Prallethrin | 23031-36-9 |
Pyrethrins* | 8003-34-7 |
Spinetoram (J&L)† | 935545-74-7 |
Spinosad‡ | 168316-95-8 |
Cat.# 32608: New York Pesticide Standard #3
Compound | CAS# |
Acetamiprid | 135410-20-7 |
Chlordane | 57-74-9 |
Clofentezine | 74115-24-5 |
Etoxazole | 153233-91-1 |
Fipronil | 120068-37-3 |
Fludioxonil | 131341-86-1 |
Imazalil | 35554-44-0 |
Imidacloprid | 138261-41-3 |
Myclobutanil | 88671-89-0 |
Paclobutrazol | 76738-62-0 |
Pentachloronitrobenzene (Quintozene) | 82-68-8 |
Propiconazole (Tilt) | 60207-90-1 |
Tebuconazole | 107534-96-3 |
Thiacloprid | 111988-49-9 |
Thiamethoxam | 153719-23-4 |
Cat.# 32609: New York Pesticide Standard #4
Compound | CAS# |
Azoxystrobin | 131860-33-8 |
Boscalid | 188425-85-6 |
Chlorantraniliprole** | 500008-45-7 |
Chlorfenapyr | 122453-73-0 |
Daminozide** | 1596-84-5 |
Dimethomorph | 110488-70-5 |
Fenhexamid | 126833-17-8 |
Fenpyroximate | 111812-58-9 |
Flonicamid | 158062-67-0 |
Hexythiazox | 78587-05-0 |
Kresoxim methyl | 143390-89-0 |
Metalaxyl | 57837-19-1 |
MGK-264 | 113-48-4 |
Piperonyl butoxide | 51-03-6 |
Pyridaben | 96489-71-3 |
Spiromesifen | 283594-90-1 |
Spirotetramat | 203313-25-1 |
Spiroxamine | 118134-30-8 |
Trifloxystrobin | 141517-21-7 |
Cat.# 32610: Captan Standard
Compound | CAS# |
Captan | 133-06-2 |
Cat.# 32611: Azadirachtin Standard
Compound | CAS# |
Azadirachtin | 11141-17-6 |
Cat.# 32612: 3-Indolebutyric Acid Standard
Compound | CAS# |
3-Indolebutyric Acid | 133-32-4 |
Cat.# 32613: Chlormequat Standard
Compound | CAS# |
Chlormequat chloride | 999-81-5 |
*This reference material contains pyrethrins, a technical mixture that is composed of six active insecticidal compounds. The ratio of each of the six compounds in this specific mixture are provided in the order they have eluted under the run conditions listed on the certificate. Only the peak corresponding to the pyrethrin compound with the highest signal intensity is labeled on the chromatogram. Due to the nature of pyrethrins, lot-to-lot variation in composition and purity may be observed based on raw material source.
†This reference material contains both the Spinetoram J and L isomers (187166-40-1 and 187166-15-0); however, CAS# 935545-74-7 is displayed on the certificate as this is the neat material dissolved in the solution. CAS# 935545-74-7 is a blend of Spinetoram J and L, and the ratio of each material isomer are displayed on your certificate of analysis.
‡This reference material contains Spinosad A and D isomers (131929-60-7 and 131929-63-0); however, CAS# 168316-95-8 is displayed on the certificate as this is the neat material dissolved in the solution. CAS# 168316-95-8 is a blend of Spinosad A and D, and the ratio of each material isomer are displayed on your certificate of analysis.
**Reference materials containing chlorantraniliprole (500008-45-7) and daminozide (1596-84-5) must be sonicated for a minimum of 60 minutes prior to opening the ampul. Because each ultrasonic bath operates at a different energy level, 60 minutes is a guideline only. Longer sonication time will not affect product quality. These precautions apply to working solutions prepared in your laboratory as well. The amount of compound that precipitates depends on concentration and temperature. If you store your standards, even dilute solutions, at a temperature well below the label recommendation, allow extra sonication time.