Catalog # | Length | ID | df | Temp. Limits | Units | |
---|---|---|---|---|---|---|
41101 | 10 m | 0.10 mm | 0.10 μm | -60 to 330/350 °C | ea. | |
41102 | 20 m | 0.10 mm | 0.10 μm | -60 to 330/360 °C | ea. | |
41103 | 10 m | 0.10 mm | 0.40 μm | -60 to 330/340 °C | ea. | |
41104 | 20 m | 0.10 mm | 0.40 μm | -60 to 330/350 °C | ea. | |
40101 | 10 m | 0.18 mm | 0.20 μm | -60 to 330/350 °C | ea. | |
40102 | 20 m | 0.18 mm | 0.20 μm | -60 to 330/350 °C | ea. | |
40103 | 40 m | 0.18 mm | 0.20 μm | -60 to 330/350 °C | ea. | |
40110 | 10 m | 0.18 mm | 0.40 μm | -60 to 330/340 °C | ea. | |
40111 | 20 m | 0.18 mm | 0.40 μm | -60 to 330/340 °C | ea. | |
40112 | 40 m | 0.18 mm | 0.40 μm | -60 to 330/340 °C | ea. | |
10105 | 15 m | 0.25 mm | 0.10 μm | -60 to 330/350 °C | ea. | |
10108 | 30 m | 0.25 mm | 0.10 μm | -60 to 330/350 °C | ea. | |
10111 | 60 m | 0.25 mm | 0.10 μm | -60 to 330/350 °C | ea. | |
10120 | 15 m | 0.25 mm | 0.25 μm | -60 to 330/350 °C | ea. | |
10123 | 30 m | 0.25 mm | 0.25 μm | -60 to 330/350 °C | ea. | |
10123-600 | 30 m | 0.25 mm | 0.25 μm | -60 to 330/350 °C | 6-pk. | |
10126 | 60 m | 0.25 mm | 0.25 μm | -60 to 330/350 °C | ea. | |
10129 | 105 m | 0.25 mm | 0.25 μm | -60 to 330/350 °C | ea. | |
10135 | 15 m | 0.25 mm | 0.50 μm | -60 to 330/350 °C | ea. | |
10138 | 30 m | 0.25 mm | 0.50 μm | -60 to 330/350 °C | ea. | |
10141 | 60 m | 0.25 mm | 0.50 μm | -60 to 330/350 °C | ea. | |
10144 | 105 m | 0.25 mm | 0.50 μm | -60 to 330/350 °C | ea. | |
10150 | 15 m | 0.25 mm | 1.00 μm | -60 to 320/340 °C | ea. | |
10153 | 30 m | 0.25 mm | 1.00 μm | -60 to 320/340 °C | ea. | |
10156 | 60 m | 0.25 mm | 1.00 μm | -60 to 320/340 °C | ea. | |
10159 | 105 m | 0.25 mm | 1.00 μm | -60 to 320/340 °C | ea. | |
10106 | 15 m | 0.32 mm | 0.10 μm | -60 to 330/350 °C | ea. | |
10109 | 30 m | 0.32 mm | 0.10 μm | -60 to 330/350 °C | ea. | |
10112 | 60 m | 0.32 mm | 0.10 μm | -60 to 330/350 °C | ea. | |
10121 | 15 m | 0.32 mm | 0.25 μm | -60 to 330/350 °C | ea. | |
10124 | 30 m | 0.32 mm | 0.25 μm | -60 to 330/350 °C | ea. | |
10127 | 60 m | 0.32 mm | 0.25 μm | -60 to 330/350 °C | ea. | |
10136 | 15 m | 0.32 mm | 0.50 μm | -60 to 330/350 °C | ea. | |
10139 | 30 m | 0.32 mm | 0.50 μm | -60 to 330/350 °C | ea. | |
10142 | 60 m | 0.32 mm | 0.50 μm | -60 to 330/350 °C | ea. | |
10151 | 15 m | 0.32 mm | 1.00 μm | -60 to 320/340 °C | ea. | |
10154 | 30 m | 0.32 mm | 1.00 μm | -60 to 320/340 °C | ea. | |
10154-600 | 30 m | 0.32 mm | 1.00 μm | -60 to 320/340 °C | 6-pk. | |
10157 | 60 m | 0.32 mm | 1.00 μm | -60 to 320/340 °C | ea. | |
10160 | 105 m | 0.32 mm | 1.00 μm | -60 to 320/340 °C | ea. | |
10166 | 15 m | 0.32 mm | 1.50 μm | -60 to 310/330 °C | ea. | |
10169 | 30 m | 0.32 mm | 1.50 μm | -60 to 310/330 °C | ea. | |
10172 | 60 m | 0.32 mm | 1.50 μm | -60 to 310/330 °C | ea. | |
10175 | 105 m | 0.32 mm | 1.50 μm | -60 to 310/330 °C | ea. | |
10181 | 15 m | 0.32 mm | 3.00 μm | -60 to 280/300 °C | ea. | |
10184 | 30 m | 0.32 mm | 3.00 μm | -60 to 280/300 °C | ea. | |
10187 | 60 m | 0.32 mm | 3.00 μm | -60 to 280/300 °C | ea. | |
10190 | 105 m | 0.32 mm | 3.00 μm | -60 to 260/280 °C | ea. | |
10198 | 30 m | 0.32 mm | 4.00 μm | -60 to 280/300 °C | ea. | |
10176 | 15 m | 0.32 mm | 5.00 μm | -60 to 260/280 °C | ea. | |
10178 | 30 m | 0.32 mm | 5.00 μm | -60 to 260/280 °C | ea. | |
10180 | 60 m | 0.32 mm | 5.00 μm | -60 to 260/280 °C | ea. | |
10180-600 | 60 m | 0.32 mm | 5.00 μm | -60 to 260/280 °C | 6-pk. | |
10107 | 15 m | 0.53 mm | 0.10 μm | -60 to 320/340 °C | ea. | |
10110 | 30 m | 0.53 mm | 0.10 μm | -60 to 320/340 °C | ea. | |
10122 | 15 m | 0.53 mm | 0.25 μm | -60 to 320/340 °C | ea. | |
10125 | 30 m | 0.53 mm | 0.25 μm | -60 to 320/340 °C | ea. | |
10128 | 60 m | 0.53 mm | 0.25 μm | -60 to 320/340 °C | ea. | |
10137 | 15 m | 0.53 mm | 0.50 μm | -60 to 310/330 °C | ea. | |
10140 | 30 m | 0.53 mm | 0.50 μm | -60 to 310/330 °C | ea. | |
10143 | 60 m | 0.53 mm | 0.50 μm | -60 to 310/330 °C | ea. | |
10152 | 15 m | 0.53 mm | 1.00 μm | -60 to 310/330 °C | ea. | |
10155 | 30 m | 0.53 mm | 1.00 μm | -60 to 310/330 °C | ea. | |
10158 | 60 m | 0.53 mm | 1.00 μm | -60 to 310/330 °C | ea. | |
10167 | 15 m | 0.53 mm | 1.50 μm | -60 to 310/330 °C | ea. | |
10170 | 30 m | 0.53 mm | 1.50 μm | -60 to 310/330 °C | ea. | |
10173 | 60 m | 0.53 mm | 1.50 μm | -60 to 310/330 °C | ea. | |
10182 | 15 m | 0.53 mm | 3.00 μm | -60 to 270/290 °C | ea. | |
10185 | 30 m | 0.53 mm | 3.00 μm | -60 to 270/290 °C | ea. | |
10188 | 60 m | 0.53 mm | 3.00 μm | -60 to 270/290 °C | ea. | |
10189 | 105 m | 0.53 mm | 3.00 μm | -60 to 270/290 °C | ea. | |
10177 | 15 m | 0.53 mm | 5.00 μm | -60 to 270/290 °C | ea. | |
10179 | 30 m | 0.53 mm | 5.00 μm | -60 to 270/290 °C | ea. | |
10179-600 | 30 m | 0.53 mm | 5.00 μm | -60 to 270/290 °C | 6-pk. | |
10183 | 60 m | 0.53 mm | 5.00 μm | -60 to 270/290 °C | ea. | |
10194 | 105 m | 0.53 mm | 5.00 μm | -60 to 240/260 °C | ea. | |
10191 | 15 m | 0.53 mm | 7.00 μm | -60 to 240/260 °C | ea. | |
10192 | 30 m | 0.53 mm | 7.00 μm | -60 to 240/260 °C | ea. | |
10193 | 60 m | 0.53 mm | 7.00 μm | -60 to 240/260 °C | ea. |