delim
Restek Searchable Chromatogram Library

Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

Gerstel MACH[x]

Enter more terms to filter the results further.

marketnum

OVIs by Dynamic Headspace and Gerstel MACH on Rtx-WAX (G16)

GC_PH00846

Column: Rtx-WAX (G16) 20 m, 0.18 mm ID, 0.4 µm,, using IP Deactivated Guard Column 5 m, 0.32 mm ID (cat.# 10044), with Universal “Y” Press-Tight Connector (cat.# 20405)
Injector: Headspace - Trap Split
Detector: FID
GC_PH00846

OVIs by Dynamic Headspace and Gerstel MACH on Rtx-624 (G43) and Rtx-WAX (G16)

GC_PH00845

Column: Rtx-624 20 m, 0.18 mm ID, 1.00 µm (cat.# 40924), and Rtx-WAX (G16) 20m, 0.18mm ID, 0.4µm (custom), using IP Deactivated Guard Column 5 m, 0.32 mm ID (cat.# 10044), with Universal “Y” Press-Tight Connector (cat.# 20405)
Injector: Headspace - Trap Split
Detector: FID
GC_PH00845

Organochlorine Pesticides on Rtx-CLPesticides2

GC_EV00895

Column: Rtx-CLPesticides2, 20 m, 0.18 mm ID, 0.14 µm (cat.# 42302)
Injector: Split
Detector: ECD
GC_EV00895

Organochlorine Pesticides on Rtx-CLPesticides

GC_EV00904

Column: Rtx-CLPesticides, 20 m, 0.18 mm ID, 0.18 µm (cat.# 42102)
Injector: Split
Detector: ECD
GC_EV00904

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us