share:
delim
Restek Searchable Chromatogram Library

Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

Refinery Gas[x]

Enter more terms to filter the results further.

marketnum

Hydrocarbon Gases on Rt-Q-BOND

GC_PC1340

Column: Rt-Q-BOND, 30 m, 0.32 mm ID, 10 µm (cat.# 19744)
Injector: Split
Detector: FID
GC_PC1340

Refinery Gas on Rt-Q-BOND

GC_PC1342

Column: Rt-Q-BOND, 30 m, 0.53 mm ID, 20 µm (cat.# 19742)
Injector: Split
Detector: FID
GC_PC1342

Refinery Gas on Rtx-DHA-100 (ASTM D2163)

GC_PC1310

Column: Rtx-DHA-100, 100 m, 0.25 mm ID, 0.50 µm (cat.# 10148)
Injector: Split
Detector: FID
GC_PC1310

Refinery Gas on Rt-Alumina BOND/Na2SO4 (ASTM D2163-14)

GC_PC1309

Column: Rt-Alumina BOND/Na2SO4, 50 m, 0.53 mm ID, 10 µm (cat.# 19756)
Injector: Split
Detector: FID
GC_PC1309

Refinery Gas Hydrocarbons on Rt-Alumina BOND/Na2SO4

GC_PC01139

Column: Rt-Alumina BOND/Na2SO4, 30 m, 0.53 mm ID, 10 µm (cat.# 19755)
Injector: Split
Detector: FID
GC_PC01139

Refinery Gas on Rt-Alumina BOND/KCl

GC_PC01088

Column: Rt-Alumina BOND/KCl, 50 m, 0.53 mm ID, 10 µm (cat.# 19760)
Injector: Split
Detector: FID
GC_PC01088

Refinery Gas

GC_PC01143

Column: Rt-QS-BOND, 30 m, 0.53 mm ID, 20 µm (cat.# 19738)
Injector: Split
Detector: TCD
GC_PC01143

Refinery Gas C1 to C5 Using n-Octane on Res-Sil C Packing

GC_PC00372

Column: SilcoSmooth Tubing, 80/100 mesh on Res-Sil C, 20ft., 1/8in. OD, 2 mm ID (cat.# 80436-800)
Injector: Not On-Column - Packed
Detector: FID
GC_PC00372

Refinery Gas Using OPN on Res-Sil C Packing

GC_PC00373

Column: SilcoSmooth tubing, 80/100 mesh on Res-Sil C packing, 12ft., 1/8in. OD, 2 mm ID (cat.# 80437-800)
Injector: On-Column - Packed
Detector: FID
GC_PC00373

Refinery Gas Calibration Standard on Refinery Gas Packed Column Set

GC_PC00374

Column: Silcosteel® tubing (cat.# 88000-875)
Injector: On-Column - Packed
Detector: FID
GC_PC00374

Refinery Gas on MXT-Alumina BOND/Na2SO4

GC_PC1183

Column: MXT-Alumina BOND/Na2SO4, 30 m, 0.53 mm ID, 10 µm (cat.# 79714)
Injector: Split
Detector: FID
GC_PC1183

Refinery Gas #6 on Rt-QS-BOND

GC_PC01014

Column: Rt-QS-BOND, 30 m, 0.53 mm ID, 20 µm (cat.# 19738)
Injector: Split
Detector: FID
GC_PC01014

Refinery Gas Mix on Rt-QS-BOND

GC_PC01054

Column: Rt-QS-BOND, 30 m, 0.53 mm ID, 20 µm (cat.# 19738)
Injector: Split
Detector: FID
GC_PC01054

Refinery Gasoline Sample on D3606 Application Column Set

GC_PC01106

Column: D3606 Application Column (2 column set) Column 1: 6' (1.8m), 1/8" OD, 2.0mm ID, nonpolar Rtx-1 Column 2: 16' (4.9m), 1/8" OD, 2.0mm ID, proprietary packing material (cat.# 83606-810)
Injector: Sample Valve
Detector: TCD
GC_PC01106

Refinery Gas on Rt-Alumina BOND (Na2SO4)

GC_PC01085

Column: Rt-Alumina BOND/Na2SO4, 50 m, 0.53 mm ID, 10 µm (cat.# 19756)
Injector: Split
Detector: FID
GC_PC01085

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us