share:
delim
Restek Searchable Chromatogram Library

Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

dual-column[x]

Enter more terms to filter the results further.

marketnum

Chlorophenoxyacid Herbicides US EPA Method 8151 Rtx-CLPesticides & Rtx-CLPesticides2

GC_EV00091

Column: Rtx-CLPesticides 30 m, 0.32 mm ID, 0.50 µm (cat.# 11139), and Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324)
Injector: Direct
Detector: ECD w/anode purge
GC_EV00091

Organochlorine Pesticides on Rtx-CLPesticides and Rtx-CLPesticides2 by EPA Method 504.1 (Dual Column Analysis)

GC_EV1227

Column: Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324), and Rtx-CLPesticides 30 m, 0.32 mm ID, 0.32 µm (cat.# 11141), using Rxi guard column 5 m, 0.32 mm ID (cat.# 10039), with universal “Y” Press-Tight connector (cat.# 20405)
Injector: Splitless
Detector: Micro-ECD
GC_EV1227

Aroclor 1221 PCBs on Rtx-CLPesticides

GC_EV00993

Column: Rtx-CLPesticides, 30 m, 0.32 mm ID, 0.32 µm (cat.# 11141)
Injector: PTV Pulsed Splitless
Detector: ECD
GC_EV00993

Aroclor 1221 PCBs on Rtx-CLPesticides2

GC_EV00993A

Column: Rtx-CLPesticides2, 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324)
Injector: PTV Pulsed Splitless
Detector: ECD
GC_EV00993A

Nitrogen/Phosphorus Pesticides & Herbicides US EPA Method 619 on Rtx-CLPesticides & Rtx-CLPesticides2 (dual column analysis)

GC_EV00056

Column: Rtx-CLPesticides 30 m, 0.32 mm ID, 0.50 µm (cat.# 11139), and Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324), using IP Deactivated Guard Column 5 m, 0.32 mm ID (cat.# 10044), with Universal Angled “Y” Press-Tight Connector (cat.# 20403)
Injector: Direct
Detector: NPD
GC_EV00056

Herbicides on Rtx-CLPesticides & Rtx-CLPesticides2

GC_EV00971

Column: Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324), and Rtx-CLPesticides 30 m, 0.32 mm ID, 0.32 µm (cat.# 11141), using Rxi deactivated guard column 5 m, 0.32 mm ID (cat.# 10039), with universal “Y” Press-Tight connector (cat.# 20405-261)
Injector: Splitless
Detector: Micro_ECD
GC_EV00971

Organochlorine Pesticides on Rtx-CLPesticides2

GC_EV00895

Column: Rtx-CLPesticides2, 20 m, 0.18 mm ID, 0.14 µm (cat.# 42302)
Injector: Split
Detector: ECD
GC_EV00895

Organochlorine Pesticides on Rtx-CLPesticides

GC_EV00904

Column: Rtx-CLPesticides, 20 m, 0.18 mm ID, 0.18 µm (cat.# 42102)
Injector: Split
Detector: ECD
GC_EV00904

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us