share:
delim
Restek Searchable Chromatogram Library

Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

1701[x]

Enter more terms to filter the results further.

marketnum

EPA Method 530 UCMR4 Standard at 10x the Method Reporting Limit on Rtx-1701 (SIM)

GC_EV1467

Column: Rtx-1701, 30 m, 0.25 mm ID, 0.25 µm (cat.# 12023)
Injector: Pulsed Splitless
Detector: MS-SIM
GC_EV1467

EPA Method 530 UCMR4 Standard at Method Reporting Limit on Rtx-1701 (SIM)

GC_EV1466

Column: Rtx-1701, 30 m, 0.25 mm ID, 0.25 µm (cat.# 12023)
Injector: Pulsed Splitless
Detector: MS-SIM
GC_EV1466

EPA Method 530 UCMR4 Standard at 10x the Method Reporting Limit on Rxi-5Sil MS (SIM)

GC_EV1465

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Pulsed Splitless
Detector: MS-SIM
GC_EV1465

EPA Method 530 UCMR4 Standard at Method Reporting Limit on Rxi-5Sil MS (SIM)

GC_EV1464

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Pulsed Splitless
Detector: MS-SIM
GC_EV1464

Substituted Pyridine on Rtx-1701

GC_CH00333

Column: Rtx-1701, 60 m, 0.53 mm ID, 3.00 µm (cat.# 12088)
Injector: Direct
Detector: FID
GC_CH00333

Solvents on Rtx-1701

GC_CH00351

Column: Rtx-1701, 60 m, 0.53 mm ID, 1.50 µm (cat.# 12073)
Injector: Direct
Detector: FID
GC_CH00351

Organochlorine Pesticides US EPA Method 8081 on Rtx-1701

GC_EV00409

Column: Rtx-1701, 30 m, 0.53 mm ID, 0.25 µm (cat.# 12025)
Injector: Direct
Detector: ECD
GC_EV00409

Organophosphorus Pesticides US EPA Method 8140/8141/8141A on Rtx-1701

GC_EV00411

Column: Rtx-1701, 30 m, 0.32 mm ID, 0.25 µm (cat.# 12024)
Injector: Splitless
Detector: FPD
GC_EV00411

Solvents (Nitrogen Containing) on Rtx-1701

GC_CH00330

Column: Rtx-1701, 30 m, 0.32 mm ID, 1.00 µm (cat.# 12054)
Injector: Split
Detector: FID
GC_CH00330

5% Fragrance Materials Association Mix on Rtx-1701

GC_FF00658

Column: Rtx-1701, 60 m, 0.25 mm ID, 0.25 µm (cat.# 12026)
Injector: Split
Detector: FID
GC_FF00658

Styrene Impurities Rtx-1701

GC_CH00357

Column: Rtx-1701, 30 m, 0.53 mm ID, 3.00 µm (cat.# 12085)
Injector: Split
Detector: FID
GC_CH00357

Underivatized Barbiturates (Acidic/Neutral Drugs) on Rtx-1701

GC_PH00263

Column: Rtx-1701, 15 m, 0.53 mm ID, 0.50 µm (cat.# 12037)
Injector: Splitless
Detector: FID
GC_PH00263

Underivatized Antidepressants (Basic Drugs) on Rtx-1701

GC_PH00264

Column: Rtx-1701, 15 m, 0.25 mm ID, 0.25 µm (cat.# 12020)
Injector: Split
Detector: FID
GC_PH00264

Antiepileptics (Underivatized) on Rtx-1701

GC_PH00266

Column: Rtx-1701, 15 m, 0.32 mm ID, 0.50 µm (cat.# 12036)
Injector: Split
Detector: FID
GC_PH00266

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us