Restek Searchable Chromatogram Library

Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

2,4-DNP[x]

Enter more terms to filter the results further.

marketnum

Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven

GC_EV1475

Column: Rxi-5Sil MS, 20 m, 0.15 mm ID, 0.15 µm (cat.# 43816)
Injector: Split
Detector: MS-Scan
GC_EV1475

Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven

GC_EV1476

Column: Rxi-5Sil MS, 20 m, 0.15 mm ID, 0.15 µm (cat.# 43816)
Injector: Split
Detector: MS-Scan
GC_EV1476

Semivolatiles on Rxi-5ms (Split Injection)

GC_EV1418

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Split
Detector: MS-Scan
GC_EV1418

Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270

GC_EV1357

Column: Rtx-5 w/ 5 m Integra-Guard, 30 m, 0.25 mm ID, 0.50 µm (cat.# 10238-124)
Injector: Pulsed Splitless
Detector: MS-Scan
GC_EV1357

9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D

GC_EV1328

Column: Rxi-5ms, 10 m, 0.18 mm ID, 0.18 µm, using Rxi-5ms 2 m, 0.18 mm ID,, with 0.4 mm OD matched press-fit, BGB (cat.# 2525LD)
Injector: Split
Detector: MS-Scan
GC_EV1328

Semivolatiles With Appendix IX on Rxi-5ms by 8270D

GC_EV1304

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Split
Detector: MS-Scan
GC_EV1304

Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)

GC_EV1248

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Split
Detector: MS-Scan
GC_EV1248

Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270

GC_EV1245

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Pulsed Splitless
Detector: MS-Scan
GC_EV1245

1,4-Dioxane, 2,4-Dinitrophenol, and Pyridine US EPA Method 8270D on Rxi-1ms

GC_EV00830

Column: Rxi-1ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13323)
Injector: Split
Detector: MS-Scan
GC_EV00830

Phenols & Benzidines US EPA Methods 604 & 605 on Rtx-5

GC_EV00033

Column: Rtx-5, 30 m, 0.53 mm ID, 1.50 µm (cat.# 10270)
Injector: Splitless
Detector: FID
GC_EV00033

Semivolatiles US EPA Method 8270 on Rtx-5Sil MS

GC_EV00545

Column: Rtx-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 12723)
Injector: Splitless
Detector: MS-Scan
GC_EV00545

Semivolatile Organics US EPA Method 8270 on Rtx-5Sil MS

GC_EV00532

Column: Rtx-5Sil MS, 30 m, 0.25 mm ID, 0.50 µm (cat.# 12738)
Injector: Splitless
Detector: MS-Scan
GC_EV00532

Phenols and Benzidines by U.S. EPA Methods 604 and 605 on Rtx-5

GC_EV00032

Column: Rtx-5, 30 m, 0.32 mm ID, 1.00 µm (cat.# 10254)
Injector: Split
Detector: FID
GC_EV00032

0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270

GC_EV1269

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Pulsed Splitless
Detector: MS-Scan
GC_EV1269

Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270

GC_EV1246

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Pulsed Splitless
Detector: MS-Scan
GC_EV1246

Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool

GC_EV01129

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Pulsed Splitless
Detector: MS-Scan
GC_EV01129

Comparison of 2,4-Dinitrophenol response with Semivolatiles wool and MS Certified wool

GC_EV01032

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Splitless
Detector: FID
GC_EV01032

Phenols by EPA Method 604 on Rtx-5

GC_EV00030

Column: Rtx-5, 30 m, 0.25 mm ID, 0.25 µm (cat.# 10223)
Injector: Split
Detector: FID
GC_EV00030

Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner

GC_EV00943

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Pulsed Splitless
Detector: MS-Scan
GC_EV00943

Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)

GC_EV00944

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.50 µm (cat.# 13638)
Injector: Pulsed Splitless
Detector: MS-Scan
GC_EV00944

Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)

GC_EV00945

Column: Rxi-5Sil MS, 20 m, 0.18 mm ID, 0.18 µm (cat.# 43602)
Injector: Pulsed Splitless
Detector: MS-Scan
GC_EV00945

Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)

GC_EV00946

Column: Rxi-5Sil MS, 20 m, 0.18 mm ID, 0.36 µm (cat.# 43604)
Injector: Pulsed Splitless
Detector: MS-Scan
GC_EV00946

Semivolatiles CLP Method on Rtx-5MS

GC_EV00544

Column: Rtx-5MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 12623)
Injector: Splitless
Detector: MS-Scan
GC_EV00544

Phenols by EPA 604 on MXT-5

GC_EV00027

Column: MXT-5, 30 m, 0.28 mm ID, 0.25 µm (cat.# 70224)
Injector: Splitless
Detector: FID
GC_EV00027

Phenols by EPA Method 604 on Rtx-200

GC_EV00028

Column: Rtx-200, 30 m, 0.32 mm ID, 0.25 µm (cat.# 15024)
Injector: Split
Detector: FID
GC_EV00028

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us