share:
delim
Restek Searchable Chromatogram Library

Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

Chlordane[x]

Enter more terms to filter the results further.

marketnum

Organochlorine Pesticides by U.S. EPA Method 8081A on Rtx-CLPesticides2 (dual column w/ Rtx-440)

GC_EV00797

Column: Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.50 µm (cat.# 11325)
Injector: Splitless
Detector: ECD
GC_EV00797

Organochlorine Pesticides by U.S. EPA Method 8081 on Rtx-50

GC_EV00410

Column: Rtx-50, 30 m, 0.53 mm ID, 0.83 µm (cat.# 10569)
Injector: Direct
Detector: ECD
GC_EV00410

Organochlorine Pesticides by U.S. EPA Method 8081 on Rtx-5

GC_EV00408

Column: Rtx-5, 30 m, 0.53 mm ID, 0.50 µm (cat.# 10240)
Injector: Direct
Detector: ECD
GC_EV00408

Organochlorine Pesticides by U.S. EPA Method 8081 on Rtx-CLPesticides2

GC_EV00734

Column: Rtx-CLPesticides2, 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324), using IP Deactivated Guard Column 5 m, 0.32 mm ID (cat.# 10044)
Injector: Splitless
Detector: ECD
GC_EV00734

Organochlorine Pesticides by EPA Method 508 on Rtx-5

GC_EV00083

Column: Rtx-5, 30 m, 0.25 mm ID, 0.25 µm (cat.# 10223)
Injector: Splitless
Detector: ECD
GC_EV00083

Organochlorine Pesticide Mix AB #2 on Rtx-CLPesticides2 and Rtx-CLPesticides (0.53 mm ID column set)

GC_EV00936

Column: Rtx-CLPesticides 30 m, 0.53 mm ID, 0.50 µm (cat.# 11140), and Rtx-CLPesticides2 30 m, 0.53 mm ID, 0.42 µm (cat.# 11340), using Rxi guard column 5 m, 0.53 mm ID (cat.# 10054), with Siltek-treated universal “Y” Press-Tight connector (cat.# 20486)
Injector: Splitless
Detector: Micro-ECD
GC_EV00936

Method 8081B Chlorinated Pesticides on Rtx-CLPesticides2

GC_EV1145

Column: Rtx-CLPesticides2, 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324)
Injector: Direct
Detector: ECD
GC_EV1145

Organochlorine Pesticides by EPA Method 8081A on Rtx-440 (dual column w/ Rtx-CLPesticides2)

GC_EV00796

Column: Rtx-440, 30 m, 0.32 mm ID, 0.50 µm (cat.# 12939)
Injector: Splitless
Detector: ECD
GC_EV00796

Organochlorine Pesticides by EPA Method 8081B on Rtx-CLPesticides/Rtx-CLPesticides2 (extended list)

GC_EV1193

Column: Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324), and Rtx-CLPesticides 30 m, 0.32 mm ID, 0.32 µm (cat.# 11141), using Rxi guard column 5 m, 0.32 mm ID (cat.# 10039), with deactivated universal “Y” Press-Tight connector (cat.# 20405-261)
Injector: Splitless
Detector: Micro-ECD
GC_EV1193

Organochlorine Pesticides by EPA 8081A on Rtx-CLPesticides & Rtx-CLPesticides2

GC_EV00077

Column: Rtx-CLPesticides 30 m, 0.32 mm ID, 0.50 µm (cat.# 11139), and Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324)
Injector: Direct
Detector: ECD
GC_EV00077

Organochlorine Pesticides on Rtx-CLPesticides Columns (0.18 mm ID column set)

GC_EV00892

Column: Rtx-CLPesticides 20 m, 0.18 mm ID, 0.18 µm (cat.# 42102), and Rtx-CLPesticides2 20 m, 0.18 mm ID, 0.14 µm (cat.# 42302), using IP deactivated guard column 5 m, 0.53 mm ID (cat.# 10045), with SeCure “Y” connector kit with universal “Y” Press-Tight® connector (cat.# 20276)
Injector: Splitless
Detector: Micro-ECD
GC_EV00892

Pesticides of U.S. EPA Method 505 on Rtx-CLPesticides and Rtx-CLPesticides2

GC_EV01004

Column: Rtx-CLPesticides 30 m, 0.32 mm ID, 0.32 µm (cat.# 11141), and Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324), using Rxi guard column 5 m, 0.32 mm ID (cat.# 10039), with deactivated universal “Y” Press-Tight connector (cat.# 20405-261)
Injector: Splitless
Detector: Micro-ECD
GC_EV01004

Organochlorine Pesticide Mix AB #2 on Rtx-CLPesticides2 and Rtx-CLPesticides (0.32 mm ID column set)

GC_EV00933

Column: Rtx-CLPesticides 30 m, 0.32 mm ID, 0.32 µm (cat.# 11141), and Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324), using Rxi guard column 5 m, 0.32 mm ID (cat.# 10039), with deactivated universal “Y” Press-Tight connector (cat.# 20405-261)
Injector: Splitless
Detector: Micro-ECD
GC_EV00933

Pesticides & Herbicides U.S. EPA Method 508.1 Rtx-CLPesticides & Rtx-CLPesticides2

GC_EV01022

Column: Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324), and Rtx-CLPesticides 30 m, 0.32 mm ID, 0.32 µm (cat.# 11141), using Rxi guard column 5 m, 0.32 mm ID (cat.# 10039), with deactivated universal “Y” Press-Tight connector (cat.# 20405-261)
Injector: Splitless
Detector: Micro-ECD
GC_EV01022

Organochlorine Pesticides on Rtx-CLPesticides2

GC_EV00895

Column: Rtx-CLPesticides2, 20 m, 0.18 mm ID, 0.14 µm (cat.# 42302)
Injector: Split
Detector: ECD
GC_EV00895

Organochlorine Pesticides on Rtx-CLPesticides

GC_EV00904

Column: Rtx-CLPesticides, 20 m, 0.18 mm ID, 0.18 µm (cat.# 42102)
Injector: Split
Detector: ECD
GC_EV00904

Organochlorine Pesticide Mix AB #2 Rtx-CLPesticides and Rtx-CLPesticides2 (0.25mm ID column set)

GC_EV00941

Column: Rtx-CLPesticides 30 m, 0.25 mm ID, 0.25 µm (cat.# 11123), and Rtx-CLPesticides2 30 m, 0.25 mm ID, 0.20 µm (cat.# 11323), using Rxi guard column 5 m, 0.25 mm ID (cat.# 10029), with Siltek-treated universal “Y” Press-Tight connector (cat.# 20486)
Injector: Splitless
Detector: ECD
GC_EV00941

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us