share:
delim
Restek Searchable Chromatogram Library

Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

D2887[x]

Enter more terms to filter the results further.

marketnum

Simulated Distillation on Rtx-1 SimDist 2887 DiatoSorb-WHP by ASTM D2887

GC_PC1299

Column: SilcoSmooth tubing, 100/120 mesh on DiatoSorb-WHP, 25 in-1, 1/8in OD, 2.0 mm ID (cat.# 80000-800)
Injector: On-Column
Detector: FID
GC_PC1299

Simulated Distillation with Nitrogen Carrier Gas on MXT-1HT SimDist by ASTM D2887-B (Accelerated)

GC_PC1306

Column: MXT-1HT SimDist, 10 m, 0.53 mm ID, 0.88 µm (cat.# 70134)
Injector: Cool On-column
Detector: FID
GC_PC1306

Simulated Distillation with Hydrogen Carrier Gas on MXT-1HT SimDist by ASTM D2887-B (Accelerated)

GC_PC1304

Column: MXT-1HT SimDist, 10 m, 0.53 mm ID, 0.88 µm (cat.# 70134)
Injector: Cool On-column
Detector: FID
GC_PC1304

Simulated Distillation with Helium Carrier Gas on MXT-1HT SimDist by ASTM D2887-B (Accelerated)

GC_PC1303

Column: MXT-1HT SimDist, 10 m, 0.53 mm ID, 0.88 µm (cat.# 70134)
Injector: Cool On-column
Detector: FID
GC_PC1303

Overlay of Blank and ASTM D2887 Reference Gas Oil on MXT-1HT SimDist using Hydrogen Carrier Gas

GC_PC1305

Column: MXT-1HT SimDist, 10 m, 0.53 mm ID, 0.88 µm (cat.# 70134)
Injector: Cool On-column
Detector: FID
GC_PC1305

C5-C72 Hydrocarbons on MXT-1HT SimDist by ASTM D7213-05 (D2887 Extended))

GC_PC1191

Column: MXT-1HT SimDist, 5 m, 0.53 mm ID, 0.10 µm (cat.# 70112)
Injector: Cold On-column
Detector: FID
GC_PC1191

Simulated Distillation (Standard Calibration) on MXT-1 SimDist

GC_PC00224

Column: MXT-1 SimDist, 6 m, 0.53 mm ID, 0.15 µm (cat.# 70101)
Injector: Cold On-column
Detector: FID
GC_PC00224

Sim Dist, ASTM D3710 (Gasoline) on Rtx-1 SimDist 2887

GC_PC00230

Column: SilcoSmooth Tubing, 25 inches-1, 1/8in. OD, 2 mm ID (cat.# 80000-800)
Injector: Not On-Column - Packed
Detector: FID
GC_PC00230

Hydrocarbons (C10-C44) on MXT-1HT SimDist

GC_PC00529

Column: MXT-1HT SimDist, 5 m, 0.53 mm ID, 0.10 µm (cat.# 70100)
Injector: On-Column
Detector: FID
GC_PC00529

Simulated Distillation (C5-C44) on Rtx-2887

GC_PC00750

Column: Rtx-2887, 10 m, 0.53 mm ID, 2.65 µm (cat.# 10199)
Injector: Direct
Detector: FID
GC_PC00750

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us