Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

Rtx-BAC2[x]

Enter more terms to filter the results further.

marketnum

Glycols on Rtx-BAC1 & Rtx-BAC2

GC_EV00474

Column: Rtx-BAC1 30 m, 0.32 mm ID, 1.80 µm (cat.# 18003), and Rtx-BAC2 30 m, 0.32 mm ID, 1.20 µm (cat.# 18002)
Injector: Split
Detector: FID
GC_EV00474

Alkyl Nitrites on Rtx-BAC1 and Rtx-BAC2 (dual column)

GC_PH00790

Column: Rtx-BAC1 30 m, 0.53 mm ID, 3.00 µm (cat.# 18001), and Rtx-BAC2 30 m, 0.53 mm ID, 2.00 µm (cat.# 18000)
Injector: Headspace - Loop
Detector: FID
GC_PH00790

γ-Butyrolactone & 1,4-Butanediol Rtx-BAC1 and Rtx-BAC2 (dual column)

GC_PH00808

Column: Rtx-BAC1 30 m, 0.32 mm ID, 1.80 µm (cat.# 18003), and Rtx-BAC2 30 m, 0.32 mm ID, 1.20 µm (cat.# 18002)
Injector: Split
Detector: FID
GC_PH00808

Blood Alcohol on Rtx-BAC1 & Rtx-BAC2 (0.53mm ID columns)

GC_PH00239

Column: Rtx-BAC1 30 m, 0.53 mm ID, 3.00 µm (cat.# 18001), and Rtx-BAC2 30 m, 0.53 mm ID, 2.00 µm (cat.# 18000)
Injector: Headspace - Syringe Split
Detector: FID
GC_PH00239

Blood Alcohol on Rtx-BAC1 & Rtx-BAC2 (0.32mm ID Columns)

GC_PH00241

Column: Rtx-BAC1 30 m, 0.32 mm ID, 1.80 µm (cat.# 18003), and Rtx-BAC2 30 m, 0.32 mm ID, 1.20 µm (cat.# 18002), using two hole ferrule
Injector: Headspace - Syringe Split
Detector: FID
GC_PH00241

gamma-Hydroxybutyrate (GHB) and gamma-Butyrolactone (GBL) on Rtx-BAC1 and Rtx-BAC2

GC_PH00870

Column: Rtx-BAC1 30 m, 0.32 mm ID, 1.8 µm (cat.# 18003), and Rtx-BAC2 30 m, 0.32 mm ID, 1.2 µm (cat.# 18002), with Universal “Y” Press-Tight Connector (cat.# 20405)
Injector: Headspace - Loop
Detector: FID
GC_PH00870

Abused Inhalants on Rtx-BAC1 & Rtx-BAC2

GC_PH00446

Column: Rtx-BAC1 30 m, 0.32 mm ID, 1.80 µm (cat.# 18003), and Rtx-BAC2 30 m, 0.32 mm ID, 1.20 µm (cat.# 18002)
Injector: Headspace - Loop
Detector: FID
GC_PH00446

Anesthetics on Rtx-BAC1 & Rtx-BAC2 (headspace analysis)

GC_PH00501_502

Column: Rtx-BAC1 30 m, 0.53 mm ID, 3.00 µm (cat.# 18001), and Rtx-BAC2 30 m, 0.53 mm ID, 2.00 µm (cat.# 18000)
Injector: Headspace - Syringe Split
Detector: FID
GC_PH00501_502

Solvents on Rtx-BAC1 & Rtx-BAC2 (headspace analysis)

GC_PH00509_510

Column: Rtx-BAC1 30 m, 0.53 mm ID, 3.00 µm (cat.# 18001), and Rtx-BAC2 30 m, 0.53 mm ID, 2.00 µm (cat.# 18000)
Injector: Headspace - Syringe Split
Detector: FID
GC_PH00509_510

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us