Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.
Enter a compound, synonym, CAS #, compound class, column name, or keyword below.
Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270
market | num | |
---|---|---|
25 µg/L 8260 MegaMix Revised on Rtx-VMSGC_EV1352![]() Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915) Injector: Purge and Trap Split Detector: MS-Scan | GC_EV | 1352 |
40 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.4GC_EV1351![]() Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915) Injector: Purge and Trap Split Detector: MS-Scan | GC_EV | 1351 |
Volatile Organics US EPA Method 8260B on Rtx-VMSGC_EV00640![]() Column: Rtx-VMS, 40 m, 0.18 mm ID, 1.00 µm (cat.# 49915) Injector: Purge and Trap Split Detector: 5973 GC/MS w/ turbomolecular pump | GC_EV | 00640 |
EPA Method 524.2, Revision 4 Rtx-VMSGC_EV00430![]() Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915) Injector: Purge and Trap Split Detector: MS-Scan | GC_EV | 00430 |
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3GC_EV1297![]() Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915) Injector: Purge and Trap Split Detector: MS-Scan | GC_EV | 1297 |
Organochlorine Pesticides on Rtx-CLPesticides and Rtx-CLPesticides2 by EPA Method 504.1 (Dual Column Analysis)GC_EV1227![]() Column: Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324), and Rtx-CLPesticides 30 m, 0.32 mm ID, 0.32 µm (cat.# 11141), using Rxi guard column 5 m, 0.32 mm ID (cat.# 10039), with universal “Y” Press-Tight connector (cat.# 20405) Injector: Splitless Detector: Micro-ECD | GC_EV | 1227 |
EPA Method 524.2 on Rtx-502.2GC_EV00010![]() Column: Rtx-502.2, 40 m, 0.18 mm ID, 1.00 µm (cat.# 40915) Injector: Purge and Trap Split Detector: MS-Scan | GC_EV | 00010 |
Volatile Organics by EPA Method 8021A/502.2 on Rtx-502.2GC_EV00419![]() Column: Rtx-502.2, 75 m, 0.45 mm ID, 2.55 µm (cat.# 10986), with Universal “Y” Press-Tight Connector (cat.# 20405) Injector: Purge and Trap Splitless Detector: µGold Tandem PID/Hall | GC_EV | 00419 |
Volatile Organics by EPA 8260B & Oxygenates on Rtx-VMSGC_EV00423![]() Column: Rtx-VMS, 60 m, 0.45 mm ID, 2.55 µm (cat.# 19909) Injector: Purge and Trap Split Detector: MS-Scan | GC_EV | 00423 |
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)GC_EV1169![]() Column: Rxi-624Sil MS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 13868) Injector: Purge and Trap Split Detector: MS-Scan | GC_EV | 1169 |
Chlorinated Disinfection Byproducts by US EPA Method 551.1 on Rtx-5GC_EV00023![]() Column: Rtx-5, 30 m, 0.25 mm ID, 1.00 µm (cat.# 10253) Injector: Split Detector: ECD | GC_EV | 00023 |
Chlorinated Disinfection Byproducts by US EPA Method 551.1 on Rtx-200GC_EV00024![]() Column: Rtx-200, 30 m, 0.25 mm ID, 1.00 µm (cat.# 15053) Injector: Split Detector: ECD | GC_EV | 00024 |
Method 8081B Chlorinated Pesticides on Rtx-CLPesticides2GC_EV1145![]() Column: Rtx-CLPesticides2, 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324) Injector: Direct Detector: ECD | GC_EV | 1145 |
Organochlorine Pesticides by EPA Method 8081B on Rtx-CLPesticides/Rtx-CLPesticides2 (extended list)GC_EV1193![]() Column: Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324), and Rtx-CLPesticides 30 m, 0.32 mm ID, 0.32 µm (cat.# 11141), using Rxi guard column 5 m, 0.32 mm ID (cat.# 10039), with deactivated universal “Y” Press-Tight connector (cat.# 20405-261) Injector: Splitless Detector: Micro-ECD | GC_EV | 1193 |
Organochlorine Pesticides by EPA 8081A on Rtx-CLPesticides & Rtx-CLPesticides2GC_EV00077![]() Column: Rtx-CLPesticides 30 m, 0.32 mm ID, 0.50 µm (cat.# 11139), and Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324) Injector: Direct Detector: ECD | GC_EV | 00077 |
Volatile Organics by EPA 8260B on Rtx-VMSGC_EV00427![]() Column: Rtx-VMS, 60 m, 0.25 mm ID, 1.40 µm (cat.# 19916) Injector: Purge and Trap Split Detector: MS-Scan | GC_EV | 00427 |
Volatile Organics by EPA 8260B on Rtx-VMSGC_EV00428![]() Column: Rtx-VMS, 20 m, 0.18 mm ID, 1.00 µm (cat.# 49914) Injector: Purge and Trap Split Detector: MS-Scan | GC_EV | 00428 |
Volatile Organics by EPA 8021 on Rtx-VRXGC_EV00001![]() Column: Rtx-VRX, 75 m, 0.45 mm ID, 2.55 µm (cat.# 19309) Injector: Purge and Trap Splitless Detector: μGold Tandem PID/HALL 2000 | GC_EV | 00001 |
Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMSGC_EV00685![]() Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.4 µm (cat.# 19915) Injector: Purge and Trap Split Detector: Agilent 5971A GC-MS | GC_EV | 00685 |
Volatile Organics by U.S. EPA Method 524.2 Revision IV on Rtx-VMSGC_EV00718![]() Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.4 µm (cat.# 19915) Injector: Purge and Trap Split Detector: MS-Scan | GC_EV | 00718 |
EDB/DBCP by EPA 504.1 on Rtx-CLPesticides & Rtx-CLPesticides2GC_EV00020![]() Column: Rtx-CLPesticides 30 m, 0.32 mm ID, 0.50 µm (cat.# 11139), and Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324), using IP Deactivated Guard Column 0.32 mm ID (cat.# 10044), with Universal Angled “Y” Press-Tight Connector (cat.# 20403) Injector: Direct Detector: ECD | GC_EV | 00020 |
Chlorinated Disinfection Byproducts, Chlorinated Solvents, and Halogenated Pesticides by EPA 551.1 on Rtx-1301GC_EV00758![]() Column: Rtx-1301, 30 m, 0.25 mm ID, 1.00 µm (cat.# 16053) Injector: Splitless Detector: ECD | GC_EV | 00758 |