Restek Searchable Chromatogram Library

Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

Filter[x]

Enter more terms to filter the results further.

Searching in: Clinical, Forensic & Toxicology
marketnum

22 Acylcarnitines and 13 Amino acids (Endogenous) in Dried Blood Spots with 16 Deuterated Internal Standards on Raptor HILIC-Si EXP Guard Cartridge Column by LC-MS/MS

LC_CF0759

Column: Raptor HILIC-Si EXP guard cartridge column (cat.# 9310A0252), Dimensions:5 mm x 2.1 mm ID, Particle Size: 2.7 µm, Temperature: 45 °C
Detector: MS/MS
LC_CF0759

EtG/EtS on Raptor EtG/EtS: Updated Method Conditions (Mobile Phase and Gradient)

LC_CF0739

Column: Raptor EtG/EtS (cat.# 9325A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 35 °C
Detector: MS/MS
LC_CF0739

d & l Amphetamines (DNPA Derivatives) in Urine by LC-MS/MS

LC_CF0737

Column: Raptor C18 (cat.# 9304A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 35 °C
Detector: MS/MS
LC_CF0737

EtG/EtS in UTAK EtG Plus Level 1 Urine Control on Raptor EtG/EtS by LC-MS/MS

LC_CF0726

Column: Raptor EtG/EtS (cat.# 9325A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 35 °C
Detector: MS/MS
LC_CF0726

Ethyl Glucuronide (EtG) and Ethyl Sulfate (EtS) in Oral Fluid on Raptor EtG/EtS

LC_CF0725

Column: Raptor EtG/EtS (cat.# 9325A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 30 °C
Detector: MS/MS
LC_CF0725

Creatine and Creatinine in Human Plasma on Raptor HILIC-Si by LC-MS/MS

LC_CF0722

Column: Raptor HILIC-Si (cat.# 9310A52), Dimensions:50 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS
LC_CF0722

Creatine and Creatinine in Human Urine on Raptor HILIC-Si by LC-MS/MS

LC_CF0723

Column: Raptor HILIC-Si (cat.# 9310A52), Dimensions:50 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS
LC_CF0723

Methylmalonic Acid in SeraFlx BIOMATRIX on Force C18 by LC-MS/MS

LC_CF0717

Column: Force C18 (cat.# 963431E), Dimensions:100 mm x 3.0 mm ID, Particle Size: 3 µm, Pore Size: 100 Å, Temperature: 35 °C
Detector: MS/MS
LC_CF0717

Bile Acids with Isomer Separation in Human Plasma on Raptor C18 (1.8 μm) by LC-MS/MS

LC_CF0712

Column: Raptor C18 (cat.# 9304252), Dimensions:50 mm x 2.1 mm ID, Particle Size: 1.8 µm, Pore Size: 90 Å, Temperature: 60 °C
Detector: MS/MS
LC_CF0712

Bile Acids in Human Plasma on Raptor C18 (1.8 μm) by LC-MS/MS

LC_CF0711

Column: Raptor C18 (cat.# 9304252), Dimensions:50 mm x 2.1 mm ID, Particle Size: 1.8 µm, Pore Size: 90 Å, Temperature: 60 °C
Detector: MS/MS
LC_CF0711

Fentanyl and Analogues in Urine on Raptor Biphenyl by LC-MS/MS

LC_CF0715

Column: Raptor Biphenyl (cat.# 9309552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS
LC_CF0715

Ethyl Glucuronide (EtG) and Ethyl Sulfate (EtS) in Urine on Raptor EtG/EtS

LC_CF0704

Column: Raptor EtG/EtS (cat.# 9325A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 35 °C
Detector: MS/MS
LC_CF0704

The Analysis of Morphine & Metabolites in Urine without Hydrolysis on Force Biphenyl

LC_CF0680

Column: Force Biphenyl (cat.# 9629252), Dimensions:50 mm x 2.1 mm ID, Particle Size: 1.8 µm, Temperature: 40 °C
Detector: MS/MS
LC_CF0680

Warfarin and Chemotherapeutic Drugs on Raptor FluoroPhenyl by LC-MS/MS

LC_CF0678

Column: Raptor FluoroPhenyl (cat.# 9319A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 50 °C
Detector: MS/MS
LC_CF0678

Vanillylmandelic Acid, Homovanillic Acid, and 5-Hydroxyindoleacetic Acid in Human Urine (Quantitative Control Level 1) on Raptor Biphenyl

LC_CF0661

Column: Raptor Biphenyl (cat.# 9309512), Dimensions:100 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 30 °C
Detector: MS/MS
LC_CF0661

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us