Restek Searchable Chromatogram Library

Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

Isomers[x]

Enter more terms to filter the results further.

marketnum

Common Dibenzo Pyrenes and Coronene on Rxi-PAH (60 m x 0.25 mm x 0.10)

GC_EV1425

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: MS-SIM
GC_EV1425

Resolution of Chrysene from Isobaric Interferences on Rxi-PAH (60 m x 0.25 mm x 0.10 µm)

GC_EV1422

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: MS-SIM
GC_EV1422

Resolution of Indeno[123-cd]pyrene from Dibenz Anthracene Isomers on Rxi-PAH (60 m x 0.25 mm x 0.10 µm)

GC_EV1424

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: MS-SIM
GC_EV1424

Resolution of Benzo Fluoranthene and Benzo Pyrene Isomers on Rxi-PAH (60 m x 0.25 mm x 0.10 µm)

GC_EV1423

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: MS-SIM
GC_EV1423

Select PAHs on Rxi-PAH (60 m x 0.25 mm x 0.10 µm)

GC_EV1417

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: MS-SIM
GC_EV1417

Glucocorticoid Isomers on Raptor Biphenyl by LC-MS/MS

LC_CF0659

Column: Raptor Biphenyl (cat.# 9309A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS
LC_CF0659

Multiclass Drug Panel on Raptor Biphenyl by LC-MS/MS

LC_CF0621

Column: Raptor Biphenyl (cat.# 9309A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Temperature: 30 °C
Detector: MS/MS
LC_CF0621

GC Multiresidue Pesticide Standard #5-ONP on Rxi-5ms by GC-MS

GC_FS0604

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Split
Detector: MS-Scan
GC_FS0604

GC Multiresidue Pesticide Standard #6-SPP on Rxi-5ms by GC-MS

GC_FS0605

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Split
Detector: MS-Scan
GC_FS0605

Resveratrol and Glucoside Derivative Isomers on Raptor ARC-18 by LC-MS/MS

LC_FF0554

Column: Raptor ARC-18 (cat.# 9314552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Temperature: 40 °C
Detector: MS/MS
LC_FF0554

Resveratrol and Glucoside Derivative Isomers Found in Red Wine on Raptor ARC-18 by LC-MS/MS

LC_FF0555

Column: Raptor ARC-18 (cat.# 9314552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Temperature: 40 °C
Detector: MS/MS
LC_FF0555

Aromatics (Xylene Isomers plus Cumene) on 5% RT-1200/1.75% Bentone 34 on 100/120 Silcoport

GC_PC00192

Column: SilcoSmooth Tubing, 100/120 mesh on Silcoport W, 1.8m, 1/8in. OD, 2 mm ID (cat.# 80125-800)
Injector: Direct
Detector: FID
GC_PC00192

Aromatics (Xylene Isomers /BTEX) on 5% Rt-1200/5% Bentone 34 on 100/120 Silcoport

GC_PC00193

Column: SilcoSmooth Tubing, 100/120 mesh on Silcoport , 2m, 1/8in. OD, 2 mm ID (cat.# 80129-800)
Injector: Direct
Detector: FID
GC_PC00193

Irone Isomers on Rt-βDEXcst

GC_FF00150

Column: Rt-βDEXcst, 30 m, 0.32 mm ID, 0.25 µm (cat.# 13102)
Injector: Split
Detector: FID
GC_FF00150

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us