share:
delim
Restek Searchable Chromatogram Library

Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

Petroleum[x]

Enter more terms to filter the results further.

marketnum

Petroleum Hydrocarbons (TPH) on Rxi-1ms

GC_EV00886

Column: Rxi-1ms, 20 m, 0.18 mm ID, 0.18 µm (cat.# 13302)
Injector: Split
Detector: FID
GC_EV00886

Alkylate Standard on Rtx-DHA 50 by Method D5134-13

GC_PC1319

Column: Rtx-DHA-50, 50 m, 0.20 mm ID, 0.50 µm (cat.# 10147)
Injector: Split
Detector: FID
GC_PC1319

Petroleum Oxygenates (MTBE) on Rtx-1

GC_PC00197

Column: Rtx-1, 60 m, 0.53 mm ID, 5.00 µm (cat.# 10183)
Injector: Direct
Detector: FID
GC_PC00197

Petroleum Oxygenates (ASTM D4815) on TCEP (Micropacked) & Rtx-1

GC_PC00194

Column: 20% TCEP on 80/100 Chromosorb PAW 0.56 m, 0.75 mm ID (cat.# 19040), and Rtx-1 (connected in series) 30 m, 0.53 mm ID, 3.00 µm (cat.# 10185)
Injector: Split
Detector: FID
GC_PC00194

Petroleum Wax on MXT-1

GC_PC00218

Column: MXT-1, 30 m, 0.28 mm ID, 0.25 µm (cat.# 70124)
Injector: Cold On-column
Detector: FID
GC_PC00218

Reformate on Rtx-1

GC_PC00210

Column: Rtx-1, 105 m, 0.25 mm ID, 0.50 µm (cat.# 10144)
Injector: Split
Detector: FID
GC_PC00210

Petroleum Oxygenates on Stabilwax

GC_PC00196

Column: Stabilwax, 30 m, 0.53 mm ID, 1.00 µm (cat.# 10655)
Injector: Direct
Detector: FID
GC_PC00196

Dibenzothiophene (Including C1-C4 Substitution) Elution Area for a Diesel Sample on Rxi-1ms and Rtx-FLD (Surface Plot, GCxGC-TOFMS, Extracted Ions)

GC_PC1210

Column: Rxi-1ms 60 m, 0.25 mm ID, 0.25 µm (cat.# 13326),  with Rxi-1ms 60 m, 0.25 mm ID, 0.25 µm (cat.# 13326)Rtx-FLD 1.5 m, 0.25 mm ID, 0.10 µm,
Injector: Split
Detector: TOFMS
GC_PC1210

Dibenzothiophene (Including C1-C4 Substitution) Elution Area for a Diesel Sample on Rxi-1ms and Rtx-FLD (Surface Plot, GCxGC-TOFMS, TIC)

GC_PC1209

Column: Rxi-1ms 60 m, 0.25 mm ID, 0.25 µm (cat.# 13326),  with Rxi-1ms 60 m, 0.25 mm ID, 0.25 µm (cat.# 13326)Rtx-FLD 1.5 m, 0.25 mm ID, 0.10 µm,
Injector: Split
Detector: TOFMS
GC_PC1209

GCxGC Contour Plot of Riser Pipe Oil in 2010 Gulf Oil Spill (Rxi-17Sil MS and Rxi-1ms)

GC_EV1229

Column: Rxi-17Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 14123)Rxi-1ms 1.2 m, 0.15 mm ID, 0.15 µm (cat.# 43800)
Injector: Splitless
Detector: TOFMS
GC_EV1229

Petroleum Oxygenates on Rt-TCEP

GC_PC00195

Column: Rt-TCEP, 60 m, 0.25 mm ID, 0.40 µm (cat.# 10999)
Injector: Split
Detector: FID
GC_PC00195

Hydrocarbons (High Temperature Petroleum Wax) on MXT-1

GC_PC00223

Column: MXT-1, 15 m, 0.53 mm ID, 0.20 µm (cat.# 70108)
Injector: PTV Splitless
Detector: FID
GC_PC00223

Volatile Petroleum Hydrocarbons (VPH) Massachusetts Department of Environmental Protection on Rtx-502.2

GC_EV00063

Column: Rtx-502.2, 105 m, 0.53 mm ID, 3.0 µm (cat.# 10910)
Injector: Purge and Trap Split
Detector: PID and FID
GC_EV00063

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us