share:
delim
Restek Searchable Chromatogram Library

Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

Rxi-1ms[x]

Enter more terms to filter the results further.

Searching in: Clinical, Forensic & Toxicology
marketnum

Mineral Spirits on Rxi-1ms

GC_PC01066

Column: Rxi-1ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13323)
Injector: Split
Detector: FID
GC_PC01066

99% Weathered Unleaded Gasoline on Rxi-1ms

GC_PC01070

Column: Rxi-1ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13323)
Injector: Split
Detector: FID
GC_PC01070

50% Weathered Diesel Fuel #2 on Rxi-1ms

GC_PC00921

Column: Rxi-1ms, 30 m, 0.25 mm ID, 0.50 µm (cat.# 13338)
Injector: Split
Detector: FID
GC_PC00921

Unleaded Gasoline on Rxi-1ms

GC_PC01071

Column: Rxi-1ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13323)
Injector: Split
Detector: FID
GC_PC01071

Unweathered Kerosene on Rxi-1ms

GC_PC01060

Column: Rxi-1ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13323)
Injector: Split
Detector: FID
GC_PC01060

Unweathered Diesel Fuel #2 on Rxi-1ms

GC_PC00922

Column: Rxi-1ms, 30 m, 0.25 mm ID, 0.50 µm (cat.# 13338)
Injector: Split
Detector: FID
GC_PC00922

Steroid Sex Hormones on Rxi-1ms

GC_PH00872

Column: Rxi-1ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13323)
Injector: Splitless
Detector: MS-Scan: Shimadzu 17A with QP5000
GC_PH00872

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us