Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

Sieve[x]

Enter more terms to filter the results further.

marketnum

Permanent Gases on Rt-Msieve 5A (15 m x 0.53 mm x 50 μm)

GC_PC1347

Column: Rt-Msieve 5A, 15 m, 0.53 mm ID, 50 µm (cat.# 19721)
Injector: Split
Detector: TCD
GC_PC1347

Permanent Gases on Rt-Msieve 5A (15 m x 0.25 mm x 20 μm)

GC_PC1349

Column: Rt-Msieve 5A, 15 m, 0.25 mm ID, 20 µm (cat.# 19773)
Injector: Split
Detector: TCD
GC_PC1349

Permanent Gases on Rt-Msieve 5A (15 m x 0.32 mm x 30 μm)

GC_PC1348

Column: Rt-Msieve 5A, 15 m, 0.32 mm ID, 30 µm (cat.# 19720)
Injector: Split
Detector: TCD
GC_PC1348

Permanent Gases and Nitrous Oxide on Rt-Msieve 5A

GC_PC1346

Column: Rt-Msieve 5A, 30 m, 0.53 mm ID, 50 µm (cat.# 19723)
Injector: Split
Detector: TCD
GC_PC1346

Permanent Gases on Capillary Rt-MSieve 5A

GC_PC1331

Column: Rt-Msieve 5A, 30 m, 0.32 mm ID, 30 µm (cat.# 19722)
Injector: Split
Detector: TCD
GC_PC1331

Oxygenates on Rtx-VMS

GC_EV00847

Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915)
Injector: Purge and Trap Split
Detector: MS-Scan
GC_EV00847

Volatile Organics US EPA CLP 04.1 on Rtx-VMS

GC_EV00812

Column: Rtx -VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915)
Injector: Purge and Trap Split
Detector: MS-Scan
GC_EV00812

Volatile Organics (Canada) on Rtx-VMS

GC_EV00813

Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915)
Injector: Purge and Trap Split
Detector: MS-Scan
GC_EV00813

Gasoline Range Organics Oxygenates Rtx-VMS

GC_EV00679

Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915)
Injector: Purge and Trap Split
Detector: MS-Scan
GC_EV00679

Sulfinert Treatment Prevents Loss of Sulfur Compounds

GC_PC1176

Column: Rtx-1, 60 m, 0.53 mm ID, 7.00 µm (cat.# 10193)
Injector: Direct
Detector: Sievers 355 SCD
GC_PC1176

Permanent Gases on Molecular Sieve 5A and Molecular Sieve 13X

GC_PC00166

Column: Molesieve 5A 1 m, 2 mm ID (cat.# 80440-800), and Molesieve 13X 2 m, 2 mm ID (cat.# 80439-800)
Injector: Direct
Detector: TCD
GC_PC00166

Permanent Gases on Rt-MSieve 5A PLOT

GC_PC00170

Column: Rt-Msieve 5A, 30 m, 0.53 mm ID, 50 µm (cat.# 19723)
Injector: Sample Valve
Detector: Valco® HID
GC_PC00170

Helium/Hydrogen Separation using Rt-Msieve 5A

GC_MS01136

Column: Rt-Msieve 5A, 30 m, 0.53 mm ID, 50 µm (cat.# 19723)
Injector: Split
Detector: TCD
GC_MS01136

Permanent Gases on MXT-Msieve 5A

GC_PC1182

Column: MXT-Msieve 5A, 30 m, 0.53 mm ID, 50 µm (cat.# 79723)
Injector: Split
Detector: μ-TCD
GC_PC1182

Permanent Gases Rt-Msieve 5A

GC_PC00898

Column: Rt-Msieve 5A, 30 m, 0.53 mm ID, 50 µm (cat.# 19723)
Injector: Sample Valve
Detector: Valco helium ionization detector
GC_PC00898

Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMS

GC_EV00685

Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.4 µm (cat.# 19915)
Injector: Purge and Trap Split
Detector: Agilent 5971A GC-MS
GC_EV00685

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us