Restek Searchable Chromatogram Library

Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

Sulfa[x]

Enter more terms to filter the results further.

marketnum

GC Amenable Pesticides Regulated by California in Brownies on Rxi-5ms

GC_GN1206

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Splitless
Detector: MS/MS
GC_GN1206

LC Multiresidue Pesticide Mix Extracted from Celery with QuEChERS Slim Pouch on Raptor ARC-18 by LC-MS/MS

LC_FS0522

Column: Raptor ARC-18 (cat.# 9314A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 50 °C
Detector: MS/MS
LC_FS0522

LC Multiresidue Pesticide Mix Extracted from Brown Rice Flour with QuEChERS Slim Pouch on Raptor ARC-18 by LC-MS/MS

LC_FS0521

Column: Raptor ARC-18 (cat.# 9314A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 50 °C
Detector: MS/MS
LC_FS0521

EtG/EtS in UTAK EtG Plus Level 1 Urine Control on Raptor EtG/EtS by LC-MS/MS

LC_CF0726

Column: Raptor EtG/EtS (cat.# 9325A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 35 °C
Detector: MS/MS
LC_CF0726

Ethyl Glucuronide (EtG) and Ethyl Sulfate (EtS) in Oral Fluid on Raptor EtG/EtS

LC_CF0725

Column: Raptor EtG/EtS (cat.# 9325A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 30 °C
Detector: MS/MS
LC_CF0725

Ethyl Glucuronide (EtG) and Ethyl Sulfate (EtS) in Urine on Raptor EtG/EtS

LC_CF0704

Column: Raptor EtG/EtS (cat.# 9325A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 35 °C
Detector: MS/MS
LC_CF0704

Dynamic Headspace USP <467> solvents on Rtx-1301 (G43)

GC_PH00811

Column: Rtx-1301 (G43), 30 m, 0.53 mm ID, 3.00 µm (cat.# 16085-126)
Injector: Headspace - Syringe Split
Detector: FID
GC_PH00811

OVIs by Dynamic Headspace and Gerstel MACH on Rtx-WAX (G16)

GC_PH00846

Column: Rtx-WAX (G16) 20 m, 0.18 mm ID, 0.4 µm,, using IP Deactivated Guard Column 5 m, 0.32 mm ID (cat.# 10044), with Universal “Y” Press-Tight Connector (cat.# 20405)
Injector: Headspace - Trap Split
Detector: FID
GC_PH00846

Sulfur Antibiotics by UHPLC on Pinnacle DB Biphenyl

LC_GN0532

Column: Pinnacle DB Biphenyl (cat.# 9409212), Dimensions:100 mm x 2.1 mm ID, Particle Size: 1.9 µm, Pore Size: 140 Å, Temperature: 25 °C
Detector: Shimadzu Prominence SPD-M20A Diode array
LC_GN0532

1,4-Dioxane in Drinking Water (5 pg On-Column) on Rxi-624Sil MS (Extracted Ion Chromatogram)

GC_EV1263

Column: Rxi-624Sil MS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 13868), using Rxi guard column 5 m, 0.25 mm ID (cat.# 10029), with Universal Press-Tight connectors (cat.# 20429)
Injector: Splitless
Detector: MS-SIM
GC_EV1263

16 hr Laboratory Air Sample with radiello 165

LC_GN0531

Column: Raptor C18 (cat.# 9304A65), Dimensions:150 mm x 4.6 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 30 °C
Detector: UV/Vis
LC_GN0531

OVIs by Dynamic Headspace and Gerstel MACH on Rtx-624 (G43) and Rtx-WAX (G16)

GC_PH00845

Column: Rtx-624 20 m, 0.18 mm ID, 1.00 µm (cat.# 40924), and Rtx-WAX (G16) 20m, 0.18mm ID, 0.4µm (custom), using IP Deactivated Guard Column 5 m, 0.32 mm ID (cat.# 10044), with Universal “Y” Press-Tight Connector (cat.# 20405)
Injector: Headspace - Trap Split
Detector: FID
GC_PH00845

Mesylate, Besylate, and Tosylate Genotoxic Impurities on Rxi-624Sil MS (extracted ion chromatograms)

GC_PH1165

Column: Rxi-624Sil MS, 20 m, 0.18 mm ID, 1.00 µm (cat.# 13865)
Injector: Splitless
Detector: MS-SIM
GC_PH1165

USP <467> Residual Solvents on Rtx-1301 (G43) by Static Headspace

GC_PH00810

Column: Rtx-1301 w/5m Integra-Guard, 30 m, 0.53 mm ID, 3.00 µm (cat.# 16085-126)
Injector: Headspace - Loop
Detector: FID
GC_PH00810

Potential Genotoxic Impurities (PGIs) on Rtx-200

GC_PH01076

Column: Rtx-200, 30 m, 0.25 mm ID, 1.0 µm (cat.# 15053)
Injector: Split
Detector: MS-Scan
GC_PH01076

dSPE vs. cSPE Sample Cleanup of Dandelion Root Powder (Dietary Supplement) on Rxi-5Sil MS

GC_FF1171

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Splitless
Detector: MS-Scan
GC_FF1171

Carfentrazone Ethyl in Dandelion Root Powder (Dietary Supplement) on Rxi-5Sil MS

GC_FF1172

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Splitless
Detector: MS-Scan
GC_FF1172

Chlorinated Pesticide Residues in Olive Oil Rtx-CLPesticides2

GC_FF01043

Column: Rtx-CLPesticides2, 30 m, 0.25 mm ID, 0.20 µm (cat.# 11323)
Injector: Splitless
Detector: MS-SIM
GC_FF01043

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us