Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

TMS[x]

Enter more terms to filter the results further.

marketnum

Noble and Permanent Gases on Rt-Msieve 5A

GC_PC1362

Column: Rt-Msieve 5A, 30 m, 0.53 mm ID, 50 µm (cat.# 19723)
Injector: Split
Detector: TCD
GC_PC1362

Permanent Gases on Rt-Msieve 5A (15 m x 0.53 mm x 50 μm)

GC_PC1347

Column: Rt-Msieve 5A, 15 m, 0.53 mm ID, 50 µm (cat.# 19721)
Injector: Split
Detector: TCD
GC_PC1347

Permanent Gases on Rt-Msieve 5A (15 m x 0.25 mm x 20 μm)

GC_PC1349

Column: Rt-Msieve 5A, 15 m, 0.25 mm ID, 20 µm (cat.# 19773)
Injector: Split
Detector: TCD
GC_PC1349

Permanent Gases on Rt-Msieve 5A (15 m x 0.32 mm x 30 μm)

GC_PC1348

Column: Rt-Msieve 5A, 15 m, 0.32 mm ID, 30 µm (cat.# 19720)
Injector: Split
Detector: TCD
GC_PC1348

Permanent Gases and Nitrous Oxide on Rt-Msieve 5A

GC_PC1346

Column: Rt-Msieve 5A, 30 m, 0.53 mm ID, 50 µm (cat.# 19723)
Injector: Split
Detector: TCD
GC_PC1346

Permanent Gases on Capillary Rt-MSieve 5A

GC_PC1331

Column: Rt-Msieve 5A, 30 m, 0.32 mm ID, 30 µm (cat.# 19722)
Injector: Split
Detector: TCD
GC_PC1331

Sugar Alcohols (TMS derivatives) 3% Rt-101 on 100/120 Silcoport

GC_FF00130

Column: 3% Rt-101 on 100/120 Silcoport, 2m, 1/8in. OD, 2 mm ID (cat.# 80400)
Injector: Splitless
Detector: FID
GC_FF00130

Sugars (TMS Derivatives) 3% Rt-101 on 100/120 Silcoport

GC_FF00129

Column: 3% Rt-101 on 100/120 Silcoport, 2m, 1/8in. OD, 2 mm ID (cat.# 80400)
Injector: Splitless
Detector: FID
GC_FF00129

Steroid Sex Hormones on Rxi-1ms

GC_PH00872

Column: Rxi-1ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13323)
Injector: Splitless
Detector: MS-Scan: Shimadzu 17A with QP5000
GC_PH00872

Cocaine and Metabolites (TMS Derivatives) on Rxi-5Sil MS (100 ng/mL)

GC_CF1149

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Splitless
Detector: MS-SIM
GC_CF1149

Permanent Gases on Rt-MSieve 5A PLOT

GC_PC00170

Column: Rt-Msieve 5A, 30 m, 0.53 mm ID, 50 µm (cat.# 19723)
Injector: Sample Valve
Detector: Valco® HID
GC_PC00170

Helium/Hydrogen Separation using Rt-Msieve 5A

GC_MS01136

Column: Rt-Msieve 5A, 30 m, 0.53 mm ID, 50 µm (cat.# 19723)
Injector: Split
Detector: TCD
GC_MS01136

Permanent Gases on MXT-Msieve 5A

GC_PC1182

Column: MXT-Msieve 5A, 30 m, 0.53 mm ID, 50 µm (cat.# 79723)
Injector: Split
Detector: μ-TCD
GC_PC1182

Permanent Gases Rt-Msieve 5A

GC_PC00898

Column: Rt-Msieve 5A, 30 m, 0.53 mm ID, 50 µm (cat.# 19723)
Injector: Sample Valve
Detector: Valco helium ionization detector
GC_PC00898

Cannabinoids (TMS Derivatives) on Rtx-5

GC_PH00253

Column: Rtx-5, 15 m, 0.25 mm ID, 0.25 µm (cat.# 10220)
Injector: Splitless
Detector: MS-Scan
GC_PH00253

Opiates (TMS Derivatives) on Rtx-5

GC_PH00233

Column: Rtx-5, 30 m, 0.25 mm ID, 0.25 µm (cat.# 10223)
Injector: Split
Detector: MS-Scan
GC_PH00233

Cocaine & Metabolites (TMS Derivatives) on Rtx-5

GC_PH00254

Column: Rtx-5, 30 m, 0.25 mm ID, 0.25 µm (cat.# 10223)
Injector: Split
Detector: FID
GC_PH00254

Derivatized Cannabinoids (5 μg/mL) on Rxi-5Sil MS

GC_CF1145

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Splitless
Detector: MS-Scan
GC_CF1145

Derivatized Cannabinoids (50 ng/mL) on Rxi-5Sil MS

GC_CF1146

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Splitless
Detector: MS-SIM
GC_CF1146

Analysis of Melamine and Related Compounds on Rxi-5Sil MS

GC_FF01094

Column: Rxi-5Sil MS w/5 m Integra-Guard column, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623-124)
Injector: Splitless
Detector: MS-SIM
GC_FF01094

Analysis of Melamine and Related Compounds in Infant Formula on Rxi-5Sil MS

GC_FF01095

Column: Rxi-5Sil MS w/5 m Integra-Guard column, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623-124)
Injector: Splitless
Detector: MS-SIM
GC_FF01095

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us