Restek Searchable Chromatogram Library
Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.
Enter a compound, synonym, CAS #, compound class, column name, or keyword below.
Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270
market | num | |
---|---|---|
4-Hr Shipping Facility Air Sample with radiello 145GC_AR1171![]() Column: Rtx-VMS, 60 m, 0.25 mm ID, 1.40 µm (cat.# 19916), with MXT low-dead-volume connector (cat.# 20536) Injector: On-Column Detector: MS-Scan | GC_AR | 1171 |
16-Hr Laboratory Air Sample with radiello 145GC_AR1170![]() Column: Rtx-VMS, 60 m, 0.25 mm ID, 1.40 µm (cat.# 19916), with MXT low-dead-volume connector (cat.# 20536) Injector: On-Column Detector: MS-Scan | GC_AR | 1170 |
25 µg/L 8260 MegaMix Revised on Rtx-VMSGC_EV1352![]() Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915) Injector: Purge and Trap Split Detector: MS-Scan | GC_EV | 1352 |
40 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.4GC_EV1351![]() Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915) Injector: Purge and Trap Split Detector: MS-Scan | GC_EV | 1351 |
Food Packaging Volatiles by Purge & Trap GCMS on Rtx-5MS, Overwrap, No SeamGC_FF00460![]() Column: Rtx-5MS, 30 m, 0.25 mm ID, 1.00 µm (cat.# 12653) Injector: Purge and Trap Split Detector: MS-Scan | GC_FF | 00460 |
Aromatics (Benzene/Toluene/Xylene) on Rtx-502.2GC_PC00190![]() Column: Rtx-502.2, 105 m, 0.53 mm ID, 3.00 µm (cat.# 10910) Injector: Split Detector: FID | GC_PC | 00190 |
Volatile Organics US EPA Method 8260B on Rtx-VMSGC_EV00640![]() Column: Rtx-VMS, 40 m, 0.18 mm ID, 1.00 µm (cat.# 49915) Injector: Purge and Trap Split Detector: 5973 GC/MS w/ turbomolecular pump | GC_EV | 00640 |
EPA Method 524.2, Revision 4 Rtx-VMSGC_EV00430![]() Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915) Injector: Purge and Trap Split Detector: MS-Scan | GC_EV | 00430 |
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3GC_EV1297![]() Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915) Injector: Purge and Trap Split Detector: MS-Scan | GC_EV | 1297 |
Food Packaging Volatiles by Purge & Trap GC/MS on Rtx-5MS, Overwrap at the SeamGC_FF00459![]() Column: Rtx-5MS, 30 m, 0.25 mm ID, 1.00 µm (cat.# 12653) Injector: Purge and Trap Split Detector: MS-Scan | GC_FF | 00459 |
Food Packaging Volatiles by Purge & Trap GC/MS on Rtx-5MSGC_FF00461![]() Column: Rtx-5MS, 30 m, 0.25 mm ID, 1.00 µm (cat.# 12653) Injector: Purge and Trap Split Detector: MS-Scan | GC_FF | 00461 |
Food Packaging Volatiles by Purge & Trap GC/MS on Rtx-5MSGC_FF00462![]() Column: Rtx-5MS, 30 m, 0.25 mm ID, 1.00 µm (cat.# 12653) Injector: Purge and Trap Split Detector: MS-Scan | GC_FF | 00462 |
EPA Method 524.2 on Rtx-502.2GC_EV00010![]() Column: Rtx-502.2, 40 m, 0.18 mm ID, 1.00 µm (cat.# 40915) Injector: Purge and Trap Split Detector: MS-Scan | GC_EV | 00010 |
Volatile Organics by EPA Method 8021A/502.2 on Rtx-502.2GC_EV00419![]() Column: Rtx-502.2, 75 m, 0.45 mm ID, 2.55 µm (cat.# 10986), with Universal “Y” Press-Tight Connector (cat.# 20405) Injector: Purge and Trap Splitless Detector: µGold Tandem PID/Hall | GC_EV | 00419 |
Volatile Organics by EPA Method 502.2 on Rtx-502.2GC_EV00005![]() Column: Rtx-502.2, 75 m, 0.45 mm ID, 2.55 µm (cat.# 10986) Injector: Purge and Trap Splitless Detector: μGold Tandem PID/HALL 2000 | GC_EV | 00005 |
Volatile Organics Confirmational Analysis by EPA Method 502.2 on Rtx-1GC_EV00006![]() Column: Rtx-1, 75 m, 0.45 mm ID, 2.55 µm (cat.# 10992) Injector: Purge and Trap Splitless Detector: μGold Tandem PID/HALL 2000 | GC_EV | 00006 |
Volatile Organics by EPA 8260B & Oxygenates on Rtx-VMSGC_EV00423![]() Column: Rtx-VMS, 60 m, 0.45 mm ID, 2.55 µm (cat.# 19909) Injector: Purge and Trap Split Detector: MS-Scan | GC_EV | 00423 |
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)GC_EV1169![]() Column: Rxi-624Sil MS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 13868) Injector: Purge and Trap Split Detector: MS-Scan | GC_EV | 1169 |
Volatiles US EPA Method 624 on Rtx-624GC_EV00701![]() Column: Rtx-624, 40 m, 0.18 mm ID, 1.00 µm (cat.# 40925) Injector: Purge and Trap Split Detector: Agilent 5971A GC/MS | GC_EV | 00701 |
Volatile Organics by EPA 8260B on Rtx-VMSGC_EV00427![]() Column: Rtx-VMS, 60 m, 0.25 mm ID, 1.40 µm (cat.# 19916) Injector: Purge and Trap Split Detector: MS-Scan | GC_EV | 00427 |
Volatile Organics by EPA 8260B on Rtx-VMSGC_EV00428![]() Column: Rtx-VMS, 20 m, 0.18 mm ID, 1.00 µm (cat.# 49914) Injector: Purge and Trap Split Detector: MS-Scan | GC_EV | 00428 |
Volatile Organics by EPA 8021 on Rtx-VRXGC_EV00001![]() Column: Rtx-VRX, 75 m, 0.45 mm ID, 2.55 µm (cat.# 19309) Injector: Purge and Trap Splitless Detector: μGold Tandem PID/HALL 2000 | GC_EV | 00001 |
Volatile Organics by U.S. EPA Method 524.2 Revision IV on Rtx-VMSGC_EV00718![]() Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.4 µm (cat.# 19915) Injector: Purge and Trap Split Detector: MS-Scan | GC_EV | 00718 |
Microbial VOCs on Rxi-1msGC_AR01030![]() Column: Rxi-1ms, 60 m, 0.25 mm ID, 1.00 µm (cat.# 13356) Injector: Split Detector: Agilent 5973 GC/MS | GC_AR | 01030 |
Food Packaging Volatiles on Rtx-5MSGC_FF00457![]() Column: Rtx-5MS, 30 m, 0.25 mm ID, 1.00 µm (cat.# 12653) Injector: Purge and Trap Split Detector: MS-Scan | GC_FF | 00457 |