Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

Dioxin[x]

Enter more terms to filter the results further.

marketnum

Tetrachlorodioxins on Rtx-Dioxin2 (60 m x 0.18 mm x 0.10 µm)

GC_EV1302

Column: Rtx-Dioxin2, 60 m, 0.18 mm ID, 0.10 µm (cat.# custom)
Injector: Splitless
Detector: HRMS-Sim
GC_EV1302

Pentachlorofurans on Rtx-Dioxin2 (60 m x 0.18 mm x 0.10 µm)

GC_EV1303

Column: Rtx-Dioxin2, 60 m, 0.18 mm ID, 0.10 µm (cat.# custom)
Injector: Splitless
Detector: HRMS-Scan
GC_EV1303

Tetrachlorofurans on Rtx-Dioxin2 (60 m x 0.18 mm x 0.10 µm)

GC_EV1301

Column: Rtx-Dioxin2, 60 m, 0.18 mm ID, 0.10 µm (cat.# custom)
Injector: Splitless
Detector: HRMS-Scan
GC_EV1301

TCDDs on Rtx-Dioxin2 Column

GC_EV1239

Column: Rtx-Dioxin2, 60 m, 0.25 mm ID, 0.25 µm (cat.# 10758)
Injector: Splitless
Detector: Micromass Autospec Ultima
GC_EV1239

TCDFs on Rtx-Dioxin2 Column

GC_EV1252

Column: Rtx-Dioxin2, 60 m, 0.25 mm ID, 0.25 µm (cat.# 10758)
Injector: Splitless
Detector: Micromass Autospec Ultima
GC_EV1252

2,3,7,8-Tetrachlorodibenzodioxin Resolved from other TCDD congeners on Rtx-Dioxin2 column.

GC_EV00948

Column: Rtx-Dioxin2, 60 m, 0.25 mm ID, 0.25 µm (cat.# 10758)
Injector: Splitless
Detector: Micromass Ultima high-resolution mass spectrometer
GC_EV00948

Tetrachlorodibenzofuran Congeners on Rtx-Dioxin2

GC_EV00949

Column: Rtx-Dioxin2, 60 m, 0.25 mm ID, 0.25 µm (cat.# 10758)
Injector: Splitless
Detector: Micromass Ultima high-resolution mass spectrometer
GC_EV00949

Dioxins (TCDDs) in Fly Ash on Rxi-5Sil MS column

GC_EV1194

Column: Rxi-5Sil MS , 60 m, 0.18 mm ID, 0.10 µm (cat.# 43607)
Injector: Splitless
Detector: Waters AutoSpec Ultima Mass Spectrometer
GC_EV1194

Furans (TCDFs) in Fly Ash on Rxi-5Sil MS

GC_EV1195

Column: Rxi-5Sil MS , 60 m, 0.18 mm ID, 0.10 µm (cat.# 43607)
Injector: Splitless
Detector: Waters AutoSpec Ultima Mass Spectrometer
GC_EV1195

Dioxins (PnCDDs) in Fly Ash on Rxi-5Sil MS

GC_EV1197

Column: Rxi-5Sil MS, 60 m, 0.18 mm ID, 0.10 µm (cat.# 43607)
Injector: Splitless
Detector: Waters AutoSpec Ultima Mass Spectrometer
GC_EV1197

Dioxins (HxCDFs) in Fly Ash on Rxi-5Sil MS

GC_EV1199

Column: Rxi-5Sil MS, 60 m, 0.18 mm ID, 0.10 µm (cat.# 43607)
Injector: Splitless
Detector: Waters AutoSpec Ultima Mass Spectrometer
GC_EV1199

GC/HR-MS analysis of tetrachlorinated dioxins in fly ash on Rtx-Dioxin2

GC_EV01026

Column: Rtx-Dioxin2, 40 m, 0.18 mm ID, 0.18 µm (cat.# 10759)
Injector: Splitless
Detector: Waters AutoSpec Ultima HRMS (SIM mode)
GC_EV01026

GC/HR-MS analysis of tetrachlorinated furans in fly ash on Rtx-Dioxin2

GC_EV01027

Column: Rtx-Dioxin2, 40 m, 0.18 mm ID, 0.18 µm (cat.# 10759)
Injector: Splitless
Detector: Waters AutoSpec Ultima HRMS (SIM mode)
GC_EV01027

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us