share:
delim
Restek Searchable Chromatogram Library

Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

Furan[x]

Enter more terms to filter the results further.

Searching in: Environmental
marketnum

CARB 1004 Aldehyde/Ketone-DNPH Calibration Standard on Raptor ARC-18

LC_EV0529

Column: Raptor ARC-18 (cat.# 9314A1E), Dimensions:100 mm x 3.0 mm ID, Particle Size: 2.7 µm, Temperature: 40 °C
Detector: Waters Acquity PDA
LC_EV0529

Combination Run of U.S. EPA Methods 521 and 522, Nitrosamines and 1,4-Dioxane, on Rxi-5Sil-MS by CSR-LVSI

GC_EV1334

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 1.00 µm (cat.# 13653), using Rxi guard column 10 m, 0.53 mm ID (cat.# 10073), with SGE µ-union
Injector: Splitless
Detector: MS-SIM
GC_EV1334

50 µL CSR-LVSI with 5 ng Nitrosamines, THF, and 1,4-Dioxane On-Column

GC_EV1342

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 1.00 µm (cat.# 13653), using Rxi guard column 10 m, 0.53 mm ID (cat.# 10073), with BGB P/N: 2553LD
Injector: Splitless
Detector: MS-SIM
GC_EV1342

10 μL CSR-LVSI with 5 ng Nitrosamines, THF, and 1,4-Dioxane On-Column

GC_EV1345

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 1.00 µm (cat.# 13653), using Rxi guard column 10 m, 0.53 mm ID (cat.# 10073), with BGB P/N: 2553LD
Injector: Splitless
Detector: MS-SIM
GC_EV1345

Pentachlorofurans on Rtx-Dioxin2 (60 m x 0.18 mm x 0.10 µm)

GC_EV1303

Column: Rtx-Dioxin2, 60 m, 0.18 mm ID, 0.10 µm (cat.# custom)
Injector: Splitless
Detector: HRMS-Scan
GC_EV1303

Tetrachlorofurans on Rtx-Dioxin2 (60 m x 0.18 mm x 0.10 µm)

GC_EV1301

Column: Rtx-Dioxin2, 60 m, 0.18 mm ID, 0.10 µm (cat.# custom)
Injector: Splitless
Detector: HRMS-Scan
GC_EV1301

1,4-Dioxane in Drinking Water (5 pg On-Column) on Rxi-624Sil MS (Extracted Ion Chromatogram)

GC_EV1263

Column: Rxi-624Sil MS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 13868), using Rxi guard column 5 m, 0.25 mm ID (cat.# 10029), with Universal Press-Tight connectors (cat.# 20429)
Injector: Splitless
Detector: MS-SIM
GC_EV1263

TCDFs on Rtx-Dioxin2 Column

GC_EV1252

Column: Rtx-Dioxin2, 60 m, 0.25 mm ID, 0.25 µm (cat.# 10758)
Injector: Splitless
Detector: Micromass Autospec Ultima
GC_EV1252

EPA 522 Analyte Mix on Rxi-624Sil MS (30 m x 0.25 mm x 1.4 μm)

GC_EV1251

Column: Rxi-624Sil MS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 13868), using Rxi guard column 5 m, 0.25 mm ID (cat.# 10029), with universal angled Press-Tight connectors (cat.# 20446-261)
Injector: Splitless
Detector: MS-SIM
GC_EV1251

EPA 522 Analyte Mix on Rtx-624 w/5 m Integra-Guard (30 m x 0.25 mm x 1.4 μm)

GC_EV1250

Column: Rtx-624 w/5 m Integra-Guard, 30 m, 0.25 mm ID, 1.40 µm (cat.# 10968-124)
Injector: Splitless
Detector: MS-SIM
GC_EV1250

EU 15+1 PAHs on Pinnacle II PAH (UV/Vis)

LC_FF0529

Column: Pinnacle II PAH (cat.# 921946E), Dimensions:150 mm x 3.0 mm ID, Particle Size: 4 µm, Pore Size: 110 Å, Temperature: 30 °C
Detector: Shimadzu Prominence SPD-M20A Diode array
LC_FF0529

Tetrachlorodibenzofuran Congeners on Rtx-Dioxin2

GC_EV00949

Column: Rtx-Dioxin2, 60 m, 0.25 mm ID, 0.25 µm (cat.# 10758)
Injector: Splitless
Detector: Micromass Ultima high-resolution mass spectrometer
GC_EV00949

GC/HR-MS analysis of tetrachlorinated dioxins in fly ash on Rtx-Dioxin2

GC_EV01026

Column: Rtx-Dioxin2, 40 m, 0.18 mm ID, 0.18 µm (cat.# 10759)
Injector: Splitless
Detector: Waters AutoSpec Ultima HRMS (SIM mode)
GC_EV01026

GC/HR-MS analysis of tetrachlorinated furans in fly ash on Rtx-Dioxin2

GC_EV01027

Column: Rtx-Dioxin2, 40 m, 0.18 mm ID, 0.18 µm (cat.# 10759)
Injector: Splitless
Detector: Waters AutoSpec Ultima HRMS (SIM mode)
GC_EV01027

Furans (TCDFs) in Fly Ash on Rxi-5Sil MS

GC_EV1195

Column: Rxi-5Sil MS , 60 m, 0.18 mm ID, 0.10 µm (cat.# 43607)
Injector: Splitless
Detector: Waters AutoSpec Ultima Mass Spectrometer
GC_EV1195

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us