Restek Searchable Chromatogram Library

Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

Glycol[x]

Enter more terms to filter the results further.

marketnum

Comparison of Glycols Before and After 600 Water Injections on Rtx-Wax

GC_EV1454

Column: Rtx-Wax, 30 m, 0.53 mm ID, 1.00 µm (cat.# 12455)
Injector: Split
Detector: FID
GC_EV1454

Glycol Ethers of Regulatory Importance on Rxi-1301Sil MS

GC_PC1280

Column: Rxi-1301Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 16094)
Injector: Split
Detector: MS-Scan
GC_PC1280

Comprehensive Glycol Ether Mix on Rxi-1301Sil MS

GC_PC1279

Column: Rxi-1301Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 16094)
Injector: Split
Detector: MS-Scan
GC_PC1279

Glycol Ethers of Regulatory Importance on Rtx-624

GC_PC1282

Column: Rtx-624, 30 m, 0.25 mm ID, 1.40 µm (cat.# 10968)
Injector: Split
Detector: MS-Scan
GC_PC1282

Custom Cleaning Solvents Standard on Stabilwax-MS

GC_GN1164

Column: Stabilwax-MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 10673)
Injector: Split
Detector: MS-Scan
GC_GN1164

Custom Solvents Mix on Stabilwax-MS

GC_GN1163

Column: Stabilwax-MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 10673)
Injector: Split
Detector: MS-Scan
GC_GN1163

Solvent Mixture #1 on Rtx-1

GC_CH00335

Column: Rtx-1, 60 m, 0.53 mm ID, 3.00 µm (cat.# 10188)
Injector: Split
Detector: MS-Scan
GC_CH00335

Solvent Mixture #1 on Rtx-200

GC_CH00336

Column: Rtx-200, 60 m, 0.53 mm ID, 3.00 µm (cat.# 15088)
Injector: Split
Detector: MS-Scan
GC_CH00336

Solvent Mixture #1 on Stabilwax

GC_CH00337

Column: Stabilwax, 60 m, 0.53 mm ID, 1.00 µm (cat.# 10658)
Injector: Split
Detector: MS-Scan
GC_CH00337

Solvent Mixture #2 on Rtx-1

GC_CH00338

Column: Rtx-1, 60 m, 0.53 mm ID, 3.00 µm (cat.# 10188)
Injector: Split
Detector: MS-Scan
GC_CH00338

Solvent Mixture #2 on Rtx-200

GC_CH00339

Column: Rtx-200, 60 m, 0.53 mm ID, 3.00 µm (cat.# 15088)
Injector: Split
Detector: MS-Scan
GC_CH00339

Solvent Mixture #2 on Stabilwax

GC_CH00340

Column: Stabilwax, 60 m, 0.53 mm ID, 1.00 µm (cat.# 10658)
Injector: Split
Detector: MS-Scan
GC_CH00340

Solvent Mixture #3 on Rtx-1

GC_CH00341

Column: Rtx-1, 60 m, 0.53 mm ID, 3.00 µm (cat.# 10188)
Injector: Split
Detector: MS-Scan
GC_CH00341

Solvent Mixture #3 on Rtx-200

GC_CH00342

Column: Rtx-200, 60 m, 0.53 mm ID, 3.00 µm (cat.# 15088)
Injector: Split
Detector: MS-Scan
GC_CH00342

Alcohols Stabilwax

GC_CH00288B

Column: Stabilwax, 60 m, 0.53 mm ID, 1.00 µm (cat.# 10658)
Injector: Split
Detector: MS-Scan
GC_CH00288B

Solvent Mixture #3 on Stabilwax

GC_CH00343

Column: Stabilwax, 60 m, 0.53 mm ID, 1.00 µm (cat.# 10658)
Injector: Split
Detector: MS-Scan
GC_CH00343

Glycols on Rtx-200

GC_CH00326

Column: Rtx-200, 60 m, 0.53 mm ID, 3.00 µm (cat.# 15088)
Injector: Split
Detector: FID
GC_CH00326

Glycols on Rtx-BAC Plus 1 and 2 Column Set

GC_CF1163

Column: Rtx-BAC Plus 1 30 m, 0.32 mm ID, 1.8 µm (cat.# 18004), and Rtx-BAC Plus 2 30 m, 0.32 mm ID, 0.6 µm (cat.# 18006), using Rxi guard column 5 m, 0.32 mm ID (cat.# 10039), with universal “Y” Press-Tight connector (cat.# 20405-261)
Injector: Split
Detector: FID
GC_CF1163

Glycols on Rtx-BAC1 & Rtx-BAC2

GC_EV00474

Column: Rtx-BAC1 30 m, 0.32 mm ID, 1.80 µm (cat.# 18003), and Rtx-BAC2 30 m, 0.32 mm ID, 1.20 µm (cat.# 18002)
Injector: Split
Detector: FID
GC_EV00474

Custom Residual Solvent Mix on Rxi-624Sil MS (using conditions from Pro ezGC)

GC_PH1150

Column: Rxi-624Sil MS, 20 m, 0.18 mm ID, 1.00 µm (cat.# 13865)
Injector: Split
Detector: FID
GC_PH1150

Cleaning Solvents on Rtx-Wax

GC_FF00644

Column: Rtx-Wax, 30 m, 0.32 mm ID, 0.25 µm (cat.# 12424)
Injector: Split
Detector: FID
GC_FF00644

Column Comparison: Limit of Ethylene Glycol and Diethylene Glycol in Propylene Glycol

GC_PH1151

Column: Rxi-624Sil MS (see notes), 30 m, 0.32 mm ID, 1.80 µm (cat.# 13870)
Injector: Split
Detector: FID
GC_PH1151

Glycols on Rtx-Wax

GC_EV00444

Column: Rtx-Wax, 30 m, 0.53 mm ID, 1.00 µm (cat.# 12455)
Injector: Direct
Detector: FID
GC_EV00444

Glycols on Rtx-200

GC_EV00445

Column: Rtx-200, 30 m, 0.53 mm ID, 1.00 µm (cat.# 15055)
Injector: Direct
Detector: FID
GC_EV00445

Cleaning Solvents on Rtx-VMS

GC_FF00645

Column: Rtx-VMS, 60 m, 0.25 mm ID, 1.40 µm (cat.# 19916)
Injector: Split
Detector: FID
GC_FF00645

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us