Restek Searchable Chromatogram Library

Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

OPP[x]

Enter more terms to filter the results further.

marketnum

trans-Fats in Frosting on Rt-2560

GC_FS0567

Column: Rt-2560, 100 m, 0.25 mm ID, 0.20 µm (cat.# 13198)
Injector: Split
Detector: FID
GC_FS0567

EPA Method 525.3 OPP Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS

GC_EV1432

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Pulsed Splitless
Detector: MS-Scan
GC_EV1432

EPA Method 525.3 Full Analyte List on Rxi-5Sil MS

GC_EV1436

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Pulsed Splitless
Detector: MS-Scan
GC_EV1436

GC Multiresidue Pesticide Standard #7-HME on Rxi-5ms by GC-MS

GC_FS0606

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Split
Detector: MS-Scan
GC_FS0606

GC Multiresidue Pesticide Standard #8-OPP on Rxi-5ms by GC-MS

GC_FS0607

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Split
Detector: MS-Scan
GC_FS0607

GC Multiresidue Pesticide Standard #9-OPP on Rxi-5ms by GC-MS

GC_FS0608

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Split
Detector: MS-Scan
GC_FS0608

GC Multiresidue Pesticide Standard #1-OPP on Rxi-5ms by GC-MS

GC_FS0600

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Split
Detector: MS-Scan
GC_FS0600

QuEChERS Performance Standards Kit Pesticides on Rxi-5ms

GC_FS0530

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Splitless
Detector: MS-Scan
GC_FS0530

GCxGC-TOFMS Contour Plot of Unfortified Detoxification Tea

GC_FS0503

Column: Rxi-5ms 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423),  with Rxi guard column 1.0 m, 0.25 mm ID (cat.# 10029)Rtx-200 1.0 m, 0.25 mm ID, 0.25 µm (cat.# 15124)
Injector: Splitless
Detector: MS-TOF
GC_FS0503

GCxGC-TOFMS Contour Plot Showing Potential Isobaric Interference with Acephate (m/z 136) in 1D Analysis

GC_FS0504

Column: Rxi-5ms 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423),  with Rxi guard column 1.0 m, 0.25 mm ID (cat.# 10029)Rtx-200 1.0 m, 0.25 mm ID, 0.25 µm (cat.# 15124)
Injector: Splitless
Detector: MS-TOF
GC_FS0504

GCxGC-TOFMS Contour Plot of Unfortified Berry Tea

GC_FS0502

Column: Rxi-5ms 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423),  with Rxi guard column 1.0 m, 0.25 mm ID (cat.# 10029)Rtx-200 1.0 m, 0.25 mm ID, 0.25 µm (cat.# 15124)
Injector: Splitless
Detector: MS-TOF
GC_FS0502

GCxGC-TOFMS Analysis of Multi-Pesticide Standard Using Rxi-5Sil MS and Rtx-200

GC_FF1241

Column: Rxi-5Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)Rtx-200 1.3 m, 0.25 mm ID, 0.25 µm (cat.# 15124)
Injector: Splitless
Detector: MS-TOF
GC_FF1241

Organophosphorus Pesticides US EPA Method 8140/8141/8141A on Rtx-1

GC_EV00415

Column: Rtx-1, 30 m, 0.32 mm ID, 0.50 µm (cat.# 10139)
Injector: Splitless
Detector: FPD
GC_EV00415

Marijuana Pesticides by GCxGC on Rxi-5Sil MS and Rtx-200

GC_FF1205

Column: Rxi-5Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)Rtx-200 1.3 m, 0.25 mm ID, 0.25 µm (cat.# 15020)
Injector: Splitless
Detector: TOFMS
GC_FF1205

Organophosphorus Pesticides (European) on Rtx-CLPesticides

GC_EV00648

Column: Rtx-CLPesticides, 30 m, 0.25 mm ID, 0.25 µm (cat.# 11123)
Injector: Splitless
Detector: MS-Scan
GC_EV00648

Organophosphorus Pesticides (European) on Rtx-CLPesticides

GC_EV00676

Column: Rtx-CLPesticides, 30 m, 0.32 mm ID, 0.50 µm (cat.# 11139)
Injector: Direct
Detector: FPD
GC_EV00676

Organophosphorous Pesticides U.S. EPA Method 8141A on Rtx-OPPesticides & Rtx-OPPesticides2

GC_EV00394

Column: Rtx-OPPesticides 30 m, 0.32 mm ID, 0.50 µm (cat.# 11239), and Rtx-OPPesticides2 30 m, 0.32 mm ID, 0.32 µm (cat.# 11241)
Injector: Splitless
Detector: FPD
GC_EV00394

Organophosphorus Pesticides by EPA Method 8140/8141/8141A on Rtx-CLPesticides

GC_EV00413

Column: Rtx-CLPesticides, 30 m, 0.32 mm ID, 0.50 µm (cat.# 11139)
Injector: Splitless
Detector: FPD
GC_EV00413

Organophosphorus Pesticides by US EPA Method 8140/8141/8141A on Rtx-CLPesticides2

GC_EV00414

Column: Rtx-CLPesticides2, 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324)
Injector: Splitless
Detector: FPD
GC_EV00414

Organophosphorus Pesticides U.S. EPA Method 8141A on Rtx-OPPesticides2

GC_EV00602

Column: Rtx-OPPesticides2, 30 m, 0.25 mm ID, 0.25 µm (cat.# 11243)
Injector: Splitless
Detector: MS-Scan
GC_EV00602

Triazine Herbicides (French) & Degradation Products on Rtx-OPPesticides2

GC_EV00626

Column: Rtx-OPPesticides2, 30 m, 0.25 mm ID, 0.25 µm (cat.# 11243)
Injector: Splitless
Detector: Agilent 5971A GC/MS
GC_EV00626

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us