share:
delim
Restek Searchable Chromatogram Library

Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

paraffins[x]

Enter more terms to filter the results further.

marketnum

Determination Of Hydrocarbon Group Type in Gasoline on Rxi-1ms by GC-VUV (ASTM D8071)

GC_PC1358

Column: Rxi-1ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13323)
Injector: Split
Detector: VUV
GC_PC1358

PiONA Calibration Standard on Rtx-DHA-100 by ASTM D6729-14

GC_PC1330

Column: Rtx-DHA-100, 100 m, 0.25 mm ID, 0.50 µm (cat.# 10148)
Injector: Split
Detector: FID
GC_PC1330

Isoparaffins on Rtx-DHA-100 (ASTM D6729-14)

GC_PC1322

Column: Rtx-DHA-100, 100 m, 0.25 mm ID, 0.50 µm (cat.# 10148)
Injector: Split
Detector: FID
GC_PC1322

Riser Pipe Oil from Deepwater Horizon Oil Spill on Rxi-17Sil and Rxi-1HT (GCxGC-TOFMS)

GC_PC1252

Column: Rxi-17Sil MS 60 m, 0.25 mm ID, 0.10 µm (cat.# custom)Rxi-1HT 1 m, 0.25 mm ID, 0.10 µm (cat.# 13950)
Injector: Split
Detector: MS-TOF
GC_PC1252

Separation of Ethanol and Aromatics from Paraffins in Gasoline with GCxGC on Rtx-DHA-150 and Stabilwax

GC_PC1227

Column: Rtx-DHA-150 150 m, 0.25 mm ID, 1.00 µm (cat.# 10149)Stabilwax 1 m, 0.18 mm ID, 0.18 µm (cat.# 15118)
Injector: Split
Detector: FID
GC_PC1227

Hydrocarbons (High Temperature Petroleum Wax) on MXT-1

GC_PC00223

Column: MXT-1, 15 m, 0.53 mm ID, 0.20 µm (cat.# 70108)
Injector: PTV Splitless
Detector: FID
GC_PC00223

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us