share:
delim
Restek Searchable Chromatogram Library

Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

Pyridine[x]

Enter more terms to filter the results further.

Searching in: Pharmaceutical
marketnum

OVIs by Dynamic Headspace and Gerstel MACH on Rtx-WAX (G16)

GC_PH00846

Column: Rtx-WAX (G16) 20 m, 0.18 mm ID, 0.4 µm,, using IP Deactivated Guard Column 5 m, 0.32 mm ID (cat.# 10044), with Universal “Y” Press-Tight Connector (cat.# 20405)
Injector: Headspace - Trap Split
Detector: FID
GC_PH00846

Organic Volatile Impurities on Rtx-5

GC_PH00256

Column: Rtx-5, 30 m, 0.53 mm ID, 5.00 µm (cat.# 10279)
Injector: Split
Detector: FID
GC_PH00256

Organic Volatile Impurities on Rtx-1301

GC_PH00257

Column: Rtx-1301, 30 m, 0.53 mm ID, 3.00 µm (cat.# 16085)
Injector: Split
Detector: FID
GC_PH00257

Residual Solvents (Class 2 - Mixture B) for Water-Soluble Articles on Rxi-624Sil MS

GC_PH1148

Column: Rxi-624Sil MS, 30 m, 0.32 mm ID, 1.80 µm (cat.# 13870)
Injector: Headspace - Loop
Detector: FID
GC_PH1148

Class 2 - Mix B Residual Solvents for Water-Insoluble Articles on Rxi-624Sil MS

GC_PH1149

Column: Rxi-624Sil MS, 30 m, 0.32 mm ID, 1.80 µm (cat.# 13870)
Injector: Headspace - Loop
Detector: FID
GC_PH1149

Custom Residual Solvent Mix on Rxi-624Sil MS (using conditions from Pro ezGC)

GC_PH1150

Column: Rxi-624Sil MS, 20 m, 0.18 mm ID, 1.00 µm (cat.# 13865)
Injector: Split
Detector: FID
GC_PH1150

Residual Solvents Class 2 Mixture B on Rtx-624

GC_PH00911

Column: Rtx-624, 30 m, 0.32 mm ID, 1.80 µm (cat.# 10970)
Injector: Headspace - Loop
Detector: FID
GC_PH00911

Residual Solvents (Class 2 - Mixture B) on Stabilwax (G16)

GC_PH00953

Column: Stabilwax, 30 m, 0.32 mm ID, 0.25 µm (cat.# 10624)
Injector: Headspace - Syringe Split
Detector: FID
GC_PH00953

Residual Solvents Rxi-624Sil MS

GC_PH01117

Column: Rxi-624Sil MS, 30 m, 0.32 mm ID, 1.80 µm (cat.# 13870)
Injector: Headspace - Syringe Split
Detector: FID
GC_PH01117

Organic Volatile Impurities on Rtx-5 (Rtx-G27)

GC_PH00260

Column: Rtx-5 w/5m Integra-Guard Column (Rtx-G27), 30 m, 0.53 mm ID, 5.00 µm (cat.# 10279-126)
Injector: Headspace-Syringe Splitless
Detector: FID
GC_PH00260

Steroid Sex Hormones on Rxi-1ms

GC_PH00872

Column: Rxi-1ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13323)
Injector: Splitless
Detector: MS-Scan: Shimadzu 17A with QP5000
GC_PH00872

OVIs by Dynamic Headspace and Gerstel MACH on Rtx-624 (G43) and Rtx-WAX (G16)

GC_PH00845

Column: Rtx-624 20 m, 0.18 mm ID, 1.00 µm (cat.# 40924), and Rtx-WAX (G16) 20m, 0.18mm ID, 0.4µm (custom), using IP Deactivated Guard Column 5 m, 0.32 mm ID (cat.# 10044), with Universal “Y” Press-Tight Connector (cat.# 20405)
Injector: Headspace - Trap Split
Detector: FID
GC_PH00845

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us