share:
delim
Restek Searchable Chromatogram Library

Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

shincarbon[x]

Enter more terms to filter the results further.

marketnum

Noble and Permanent Gases on ShinCarbon

GC_PC1363

Column: ShinCarbon ST micropacked column, 100/120 mesh, 2m, 1.00 mm ID (cat.# 19808)
Injector: Split
Detector: TCD
GC_PC1363

Permanent Gases and Nitrous Oxide on ShinCarbon ST Micropacked Column

GC_PC1343

Column: ShinCarbon ST micropacked column, 100/120 mesh, 2 m, 1.00 mm ID (cat.# 19808)
Injector: Split
Detector: TCD
GC_PC1343

Natural Gas ShinCarbon ST (micropacked)

GC_PC00672

Column: SilcoSmooth® tubing, 100/120 mesh on Shincarbon ST, 1m, 1/16-1 OD, 1.0 mm ID (cat.# 19809)
Injector: On-Column - Packed
Detector: FID
GC_PC00672

Chlorofluorocarbon Gases on ShinCarbon ST (micropacked)

GC_PC00673

Column: SilcoSmooth® tubing, 100/120 mesh on ShinCarbon ST, 1 m-1, 1/16-1 OD, 1.0 mm ID (cat.# 19809)
Injector: On-Column - Packed
Detector: FID
GC_PC00673

Permanent Gases on ShinCarbon ST (micropacked)

GC_PC00666

Column: ShinCarbon ST, 100/120 mesh, 2m, 1/16in. OD, 1.0 mm ID (cat.# 19808)
Injector: On-Column - Packed
Detector: HID
GC_PC00666

Permanent Gases and C1+C2 Hydrocarbons on ShinCarbon ST (micropacked)

GC_PC00665

Column: ShinCarbon ST, 100/120 mesh, 2m, 1/16in. OD, 1.0 mm ID (cat.# 19808)
Injector: On-Column - Packed
Detector: HID
GC_PC00665

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us