share:
delim
Restek Searchable Chromatogram Library

Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

Triazine[x]

Enter more terms to filter the results further.

marketnum

Select Carbamate, Organophosphorus, Aniline, Conazole, Phenylurea, Strobilurin, and Triazine Pesticides by GCxGC-TOFMS Using Rxi-5Sil MS and Rtx-200

GC_FF1215

Column: Rxi-5Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)Rtx-200 1.5 m, 0.18 mm ID, 0.20 µm (cat.# 45001)
Injector: Splitless
Detector: TOFMS
GC_FF1215

Triazine Herbicides by US EPA Method 619 on Rtx-50

GC_EV00058

Column: Rtx-50, 30 m, 0.53 mm ID, 0.50 µm (cat.# 10540)
Injector: Direct
Detector: NPD
GC_EV00058

Triazine Herbicides by US EPA Method 619 on Rtx-200

GC_EV00059

Column: Rtx-200, 30 m, 0.53 mm ID, 0.50 µm (cat.# 15040)
Injector: Direct
Detector: NPD
GC_EV00059

Triazine Herbicides (French) & Degradation Products on Rtx-OPPesticides2

GC_EV00626

Column: Rtx-OPPesticides2, 30 m, 0.25 mm ID, 0.25 µm (cat.# 11243)
Injector: Splitless
Detector: Agilent 5971A GC/MS
GC_EV00626

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us