Restek Searchable Chromatogram Library
Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.
Enter a compound, synonym, CAS #, compound class, column name, or keyword below.
Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270
market | num | |
---|---|---|
Antipsychotics and Antidepressants in Human Urine on Raptor Biphenyl by LC-MS/MSLC_CF0749![]() Column: Raptor Biphenyl (cat.# 9309A5E), Dimensions:50 mm x 3.0 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 30 °C Detector: MS/MS | LC_CF | 0749 |
d & l Amphetamines (DNPA Derivatives) in Urine by LC-MS/MSLC_CF0737![]() Column: Raptor C18 (cat.# 9304A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 35 °C Detector: MS/MS | LC_CF | 0737 |
EtG/EtS in UTAK EtG Plus Level 1 Urine Control on Raptor EtG/EtS by LC-MS/MSLC_CF0726![]() Column: Raptor EtG/EtS (cat.# 9325A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 35 °C Detector: MS/MS | LC_CF | 0726 |
Creatine and Creatinine in Human Urine on Raptor HILIC-Si by LC-MS/MSLC_CF0723![]() Column: Raptor HILIC-Si (cat.# 9310A52), Dimensions:50 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 40 °C Detector: MS/MS | LC_CF | 0723 |
Fentanyl and Analogues in Urine on Raptor Biphenyl by LC-MS/MSLC_CF0715![]() Column: Raptor Biphenyl (cat.# 9309552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 40 °C Detector: MS/MS | LC_CF | 0715 |
Ethyl Glucuronide (EtG) and Ethyl Sulfate (EtS) in Urine on Raptor EtG/EtSLC_CF0704![]() Column: Raptor EtG/EtS (cat.# 9325A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 35 °C Detector: MS/MS | LC_CF | 0704 |
Catecholamines and Metabolites in Human Urine on Raptor Biphenyl by LC-MS/MSLC_CF0703![]() Column: Raptor Biphenyl (cat.# 9309A62), Dimensions:150 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 30 °C Detector: MS/MS | LC_CF | 0703 |
Cortisol and Cortisone in Extracted Female Human Urine on Raptor Biphenyl by LC-MS/MSLC_CF0697![]() Column: Raptor Biphenyl (cat.# 9309A52), Dimensions:50 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 40 °C Detector: MS/MS | LC_CF | 0697 |
The Analysis of Morphine & Metabolites in Urine without Hydrolysis on Force BiphenylLC_CF0680![]() Column: Force Biphenyl (cat.# 9629252), Dimensions:50 mm x 2.1 mm ID, Particle Size: 1.8 µm, Temperature: 40 °C Detector: MS/MS | LC_CF | 0680 |
Vanillylmandelic Acid, Homovanillic Acid, and 5-Hydroxyindoleacetic Acid in Human Urine (Quantitative Control Level 1) on Raptor BiphenylLC_CF0661![]() Column: Raptor Biphenyl (cat.# 9309512), Dimensions:100 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 30 °C Detector: MS/MS | LC_CF | 0661 |
Combined Analysis of Synthetic Cannabinoids & Metabolites in Urine by LC-MS/MS on Raptor BiphenylLC_CF0613![]() Column: Raptor Biphenyl (cat.# 9309A5E), Dimensions:50 mm x 3.0 mm ID, Particle Size: 2.7 µm Detector: MS/MS | LC_CF | 0613 |
Synthetic Cannabinoids in Urine by LC-MS/MS on Raptor BiphenylLC_CF0612![]() Column: Raptor Biphenyl (cat.# 9309A5E), Dimensions:50 mm x 3.0 mm ID, Particle Size: 2.7 µm Detector: MS/MS | LC_CF | 0612 |
Nicotine-Related Compounds in Urine on Raptor Biphenyl by LC-MS/MSLC_CF0606![]() Column: Raptor Biphenyl (cat.# 9309512), Dimensions:100 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 30 °C Detector: MS/MS | LC_CF | 0606 |
Fentanyl, Metabolite, and Analogues in Urine on Raptor Biphenyl by LC-MS/MSLC_CF0591![]() Column: Raptor Biphenyl (cat.# 9309552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Temperature: 30 °C Detector: MS/MS | LC_CF | 0591 |
Naltrexone and 6-β-Naltrexol in Urine on Raptor Biphenyl by LC-MS/MSLC_CF0588![]() Column: Raptor Biphenyl (cat.# 9309552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 30 °C Detector: MS/MS | LC_CF | 0588 |
Synthetic Cannabinoid Metabolites in Urine on Raptor Biphenyl by LC-MS/MSLC_CF0585![]() Column: Raptor Biphenyl (cat.# 9309A5E), Dimensions:50 mm x 3.0 mm ID, Particle Size: 2.7 µm, Temperature: 30 °C Detector: Waters Xevo TQ-S | LC_CF | 0585 |
Norbuprenorphine & Buprenorphine in Urine on Raptor Biphenyl by LC-MS/MSLC_CF0580![]() Column: Raptor Biphenyl (cat.# 9309A5E), Dimensions:50 mm x 3.0 mm ID, Particle Size: 2.7 µm, Temperature: 30 °C Detector: AB SCIEX API 4000 MS/MS | LC_CF | 0580 |
Synthetic Cannabinoids in Urine on Raptor Biphenyl by LC-MS/MSLC_CF0584![]() Column: Raptor Biphenyl (cat.# 9309A5E), Dimensions:50 mm x 3.0 mm ID, Particle Size: 2.7 µm, Temperature: 30 °C Detector: Waters Xevo TQ-S | LC_CF | 0584 |
Benzodiazepines in Urine on Raptor Biphenyl by LC-MS/MSLC_CF0581![]() Column: Raptor Biphenyl (cat.# 9309A5E), Dimensions:50 mm x 3.0 mm ID, Particle Size: 2.7 µm, Temperature: 40 °C Detector: ABSCIEX API 4000 MS/MS | LC_CF | 0581 |
Therapeutic Drugs in Urine on Raptor Biphenyl by LC-MS/MSLC_CF0579![]() Column: Raptor Biphenyl (cat.# 9309A5E), Dimensions:50 mm x 3.0 mm ID, Particle Size: 2.7 µm, Pore Size: 100 Å, Temperature: 40 °C Detector: ABSCIEX API 4000 MS/MS | LC_CF | 0579 |
THC + Metabolites in Urine on Raptor Biphenyl by LC-MS/MSLC_CF0583![]() Column: Raptor Biphenyl (cat.# 9309A5E), Dimensions:50 mm x 3.0 mm ID, Particle Size: 2.7 µm, Temperature: 40 °C Detector: Waters Xevo TQ-S | LC_CF | 0583 |
Pain Panel in Urine on Raptor Biphenyl (50 x 3.0 mm) by LC-MS/MSLC_CF0568![]() Column: Raptor Biphenyl (cat.# 9309A5E), Dimensions:50 mm x 3.0 mm ID, Particle Size: 2.7 µm, Temperature: 30 °C Detector: AB SCIEX API 4000 MS/MS | LC_CF | 0568 |
100 ng/mL Benzodiazepines in Hydrolyzed Urine on Ultra Biphenyl by LC-MS/MSLC_CF0525![]() Column: Ultra Biphenyl (cat.# 9109552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 100 Å, Temperature: 40 °C Detector: AB SCIEX API 4000 MS/MS | LC_CF | 0525 |
GHB (analyzed as GBL) in Urine on Rtx-5MSGC_CF01038![]() Column: Rtx-5MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 12623) Injector: Headspace - Syringe Split Detector: MS-Scan | GC_CF | 01038 |
Comparison of Converted and Unconverted GHB on Rtx-BAC1GC_CF01039![]() Column: Rtx-BAC1, 30 m, 0.32 mm ID, 1.80 µm (cat.# 18003) Injector: Headspace - Syringe Split Detector: FID | GC_CF | 01039 |