share:
delim
Restek Searchable Chromatogram Library

Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

voc[x]

Enter more terms to filter the results further.

marketnum

4-Hr Shipping Facility Air Sample with radiello 145

GC_AR1171

Column: Rtx-VMS, 60 m, 0.25 mm ID, 1.40 µm (cat.# 19916), with MXT low-dead-volume connector (cat.# 20536)
Injector: On-Column
Detector: MS-Scan
GC_AR1171

16-Hr Laboratory Air Sample with radiello 145

GC_AR1170

Column: Rtx-VMS, 60 m, 0.25 mm ID, 1.40 µm (cat.# 19916), with MXT low-dead-volume connector (cat.# 20536)
Injector: On-Column
Detector: MS-Scan
GC_AR1170

25 µg/L 8260 MegaMix Revised on Rtx-VMS

GC_EV1352

Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915)
Injector: Purge and Trap Split
Detector: MS-Scan
GC_EV1352

40 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.4

GC_EV1351

Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915)
Injector: Purge and Trap Split
Detector: MS-Scan
GC_EV1351

Food Packaging Volatiles by Purge & Trap GCMS on Rtx-5MS, Overwrap, No Seam

GC_FF00460

Column: Rtx-5MS, 30 m, 0.25 mm ID, 1.00 µm (cat.# 12653)
Injector: Purge and Trap Split
Detector: MS-Scan
GC_FF00460

Aromatics (Benzene/Toluene/Xylene) on Rtx-502.2

GC_PC00190

Column: Rtx-502.2, 105 m, 0.53 mm ID, 3.00 µm (cat.# 10910)
Injector: Split
Detector: FID
GC_PC00190

Volatile Organics US EPA Method 8260B on Rtx-VMS

GC_EV00640

Column: Rtx-VMS, 40 m, 0.18 mm ID, 1.00 µm (cat.# 49915)
Injector: Purge and Trap Split
Detector: 5973 GC/MS w/ turbomolecular pump
GC_EV00640

EPA Method 524.2, Revision 4 Rtx-VMS

GC_EV00430

Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915)
Injector: Purge and Trap Split
Detector: MS-Scan
GC_EV00430

5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3

GC_EV1297

Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915)
Injector: Purge and Trap Split
Detector: MS-Scan
GC_EV1297

Food Packaging Volatiles by Purge & Trap GC/MS on Rtx-5MS, Overwrap at the Seam

GC_FF00459

Column: Rtx-5MS, 30 m, 0.25 mm ID, 1.00 µm (cat.# 12653)
Injector: Purge and Trap Split
Detector: MS-Scan
GC_FF00459

Food Packaging Volatiles by Purge & Trap GC/MS on Rtx-5MS

GC_FF00461

Column: Rtx-5MS, 30 m, 0.25 mm ID, 1.00 µm (cat.# 12653)
Injector: Purge and Trap Split
Detector: MS-Scan
GC_FF00461

Food Packaging Volatiles by Purge & Trap GC/MS on Rtx-5MS

GC_FF00462

Column: Rtx-5MS, 30 m, 0.25 mm ID, 1.00 µm (cat.# 12653)
Injector: Purge and Trap Split
Detector: MS-Scan
GC_FF00462

EPA Method 524.2 on Rtx-502.2

GC_EV00010

Column: Rtx-502.2, 40 m, 0.18 mm ID, 1.00 µm (cat.# 40915)
Injector: Purge and Trap Split
Detector: MS-Scan
GC_EV00010

Volatile Organics by EPA Method 8021A/502.2 on Rtx-502.2

GC_EV00419

Column: Rtx-502.2, 75 m, 0.45 mm ID, 2.55 µm (cat.# 10986), with Universal “Y” Press-Tight Connector (cat.# 20405)
Injector: Purge and Trap Splitless
Detector: µGold Tandem PID/Hall
GC_EV00419

Volatile Organics by EPA Method 502.2 on Rtx-502.2

GC_EV00005

Column: Rtx-502.2, 75 m, 0.45 mm ID, 2.55 µm (cat.# 10986)
Injector: Purge and Trap Splitless
Detector: μGold Tandem PID/HALL 2000
GC_EV00005

Volatile Organics Confirmational Analysis by EPA Method 502.2 on Rtx-1

GC_EV00006

Column: Rtx-1, 75 m, 0.45 mm ID, 2.55 µm (cat.# 10992)
Injector: Purge and Trap Splitless
Detector: μGold Tandem PID/HALL 2000
GC_EV00006

Volatile Organics by EPA 8260B & Oxygenates on Rtx-VMS

GC_EV00423

Column: Rtx-VMS, 60 m, 0.45 mm ID, 2.55 µm (cat.# 19909)
Injector: Purge and Trap Split
Detector: MS-Scan
GC_EV00423

Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)

GC_EV1169

Column: Rxi-624Sil MS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 13868)
Injector: Purge and Trap Split
Detector: MS-Scan
GC_EV1169

Volatiles US EPA Method 624 on Rtx-624

GC_EV00701

Column: Rtx-624, 40 m, 0.18 mm ID, 1.00 µm (cat.# 40925)
Injector: Purge and Trap Split
Detector: Agilent 5971A GC/MS
GC_EV00701

Volatile Organics by EPA 8260B on Rtx-VMS

GC_EV00427

Column: Rtx-VMS, 60 m, 0.25 mm ID, 1.40 µm (cat.# 19916)
Injector: Purge and Trap Split
Detector: MS-Scan
GC_EV00427

Volatile Organics by EPA 8260B on Rtx-VMS

GC_EV00428

Column: Rtx-VMS, 20 m, 0.18 mm ID, 1.00 µm (cat.# 49914)
Injector: Purge and Trap Split
Detector: MS-Scan
GC_EV00428

Volatile Organics by EPA 8021 on Rtx-VRX

GC_EV00001

Column: Rtx-VRX, 75 m, 0.45 mm ID, 2.55 µm (cat.# 19309)
Injector: Purge and Trap Splitless
Detector: μGold Tandem PID/HALL 2000
GC_EV00001

Volatile Organics by U.S. EPA Method 524.2 Revision IV on Rtx-VMS

GC_EV00718

Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.4 µm (cat.# 19915)
Injector: Purge and Trap Split
Detector: MS-Scan
GC_EV00718

Microbial VOCs on Rxi-1ms

GC_AR01030

Column: Rxi-1ms, 60 m, 0.25 mm ID, 1.00 µm (cat.# 13356)
Injector: Split
Detector: Agilent 5973 GC/MS
GC_AR01030

Food Packaging Volatiles on Rtx-5MS

GC_FF00457

Column: Rtx-5MS, 30 m, 0.25 mm ID, 1.00 µm (cat.# 12653)
Injector: Purge and Trap Split
Detector: MS-Scan
GC_FF00457

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us