share:
delim
Restek Searchable Chromatogram Library

Restek Searchable Chromatogram Library

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

volatiles[x]

Enter more terms to filter the results further.

Searching in: GC, MS, Splitless
marketnum

Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270

GC_EV1357

Column: Rtx-5 w/ 5 m Integra-Guard, 30 m, 0.25 mm ID, 0.50 µm (cat.# 10238-124)
Injector: Pulsed Splitless
Detector: MS-Scan
GC_EV1357

Semivolatiles US EPA Method 8270 on Rtx-5Sil MS

GC_EV00545

Column: Rtx-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 12723)
Injector: Splitless
Detector: MS-Scan
GC_EV00545

Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool

GC_EV01129

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Pulsed Splitless
Detector: MS-Scan
GC_EV01129

Peak Shape Comparison of Early Eluting Semivolatiles Using Split (10:1) and Splitless Injection at 80 °C Oven Start Temp.

GC_EV1190

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Splitless
Detector: MS-Scan
GC_EV1190

Semivolatiles on Rxi-5ms by EPA Method 525.2

GC_EV00859

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Pulsed Splitless
Detector: MS-Scan
GC_EV00859

Mass APH on Rxi-1ms

GC_AR1145

Column: Rxi-1ms, 60 m, 0.32 mm ID, 1.00 µm (cat.# 13357)
Injector: Splitless
Detector: MS-Scan
GC_AR1145

Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner

GC_EV00943

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Pulsed Splitless
Detector: MS-Scan
GC_EV00943

Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)

GC_EV00944

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.50 µm (cat.# 13638)
Injector: Pulsed Splitless
Detector: MS-Scan
GC_EV00944

Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)

GC_EV00945

Column: Rxi-5Sil MS, 20 m, 0.18 mm ID, 0.18 µm (cat.# 43602)
Injector: Pulsed Splitless
Detector: MS-Scan
GC_EV00945

Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)

GC_EV00946

Column: Rxi-5Sil MS, 20 m, 0.18 mm ID, 0.36 µm (cat.# 43604)
Injector: Pulsed Splitless
Detector: MS-Scan
GC_EV00946

Semivolatiles CLP Method on Rtx-5MS

GC_EV00544

Column: Rtx-5MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 12623)
Injector: Splitless
Detector: MS-Scan
GC_EV00544

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)
Drag and Drop Attachments Here (optional)
...


all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us